Literature DB >> 20656835

Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results.

Daniele Marin1, Rendon C Nelson, Huiman Barnhart, Sebastian T Schindera, Lisa M Ho, Tracy A Jaffe, Terry T Yoshizumi, Richard Youngblood, Ehsan Samei.   

Abstract

PURPOSE: To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase.
MATERIALS AND METHODS: This prospective, single-center, HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Twenty-seven patients (nine men, 18 women; mean age, 64 years) with 23 solitary pancreatic tumors underwent dual-energy CT. Two imaging protocols were used: 140 kVp and 385 mA (protocol A) and 80 kVp and 675 mA (protocol B). For both protocols, the following variables were compared during the pancreatic parenchymal phase: contrast enhancement for the aorta, the pancreas, and the portal vein; pancreas-to-tumor contrast-to-noise ratio (CNR); noise; and effective dose. Two blinded, independent readers qualitatively scored the two data sets for tumor detection and image quality. Random-effect analysis of variance tests were used to compare differences between the two protocols.
RESULTS: Compared with protocol A, protocol B yielded significantly higher contrast enhancement for the aorta (508.6 HU vs 221.5 HU, respectively), pancreas (151.2 HU vs 67.0 HU), and portal vein (189.7 HU vs 87.3 HU), along with a greater pancreas-to-tumor CNR (8.1 vs 5.9) (P < .001 for all comparisons). No statistically significant difference in tumor detection was observed between the two protocols. Although standard deviation of image noise increased with protocol B (11.5 HU vs 18.6 HU), this protocol significantly reduced the effective dose (from 18.5 to 5.1 mSv; P < .001).
CONCLUSION: A low-tube-voltage, high-tube-current CT technique has the potential to improve the enhancement of the pancreas and peripancreatic vasculature, improve tumor conspicuity, and reduce patient radiation dose during the pancreatic parenchymal phase.

Entities:  

Mesh:

Year:  2010        PMID: 20656835     DOI: 10.1148/radiol.10091819

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  32 in total

Review 1.  Advanced imaging techniques for chronic pancreatitis.

Authors:  Anushri Parakh; Temel Tirkes
Journal:  Abdom Radiol (NY)       Date:  2020-05

Review 2.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

3.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

4.  Impact of knowledge-based iterative model reconstruction on myocardial late iodine enhancement in computed tomography and comparison with cardiac magnetic resonance.

Authors:  Yuki Tanabe; Teruhito Kido; Akira Kurata; Naoki Fukuyama; Takahiro Yokoi; Tomoyuki Kido; Teruyoshi Uetani; Mani Vembar; Amar Dhanantwari; Shinichi Tokuyasu; Natsumi Yamashita; Teruhito Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2017-04-13       Impact factor: 2.357

5.  Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

Authors:  André Euler; Bram Stieltjes; Zsolt Szucs-Farkas; Reto Eichenberger; Clemens Reisinger; Anna Hirschmann; Caroline Zaehringer; Achim Kircher; Matthias Streif; Sabine Bucher; David Buergler; Luigia D'Errico; Sebastién Kopp; Markus Wilhelm; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2017-04-03       Impact factor: 5.315

6.  "Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT.

Authors:  Katherine E Maturen; Ravi K Kaza; Peter S Liu; Leslie E Quint; Shokoufeh H Khalatbari; Joel F Platt
Journal:  J Comput Assist Tomogr       Date:  2012 Jan-Feb       Impact factor: 1.826

Review 7.  Recent developments of dual-energy CT in oncology.

Authors:  David Simons; Marc Kachelriess; Heinz-Peter Schlemmer
Journal:  Eur Radiol       Date:  2014-01-09       Impact factor: 5.315

Review 8.  Updates on Imaging of Liver Tumors.

Authors:  Arya Haj-Mirzaian; Ana Kadivar; Ihab R Kamel; Atif Zaheer
Journal:  Curr Oncol Rep       Date:  2020-04-16       Impact factor: 5.075

9.  Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.

Authors:  Claudia Frellesen; Wenzel Stock; J Matthias Kerl; Thomas Lehnert; Julian L Wichmann; Christoph Nau; Emanuel Geiger; Sebastian Wutzler; Martin Beeres; Boris Schulz; Boris Bodelle; Hanns Ackermann; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

10.  Pancreatic neuroendocrine tumour (PNET): Staging accuracy of MDCT and its diagnostic performance for the differentiation of PNET with uncommon CT findings from pancreatic adenocarcinoma.

Authors:  Jung Hoon Kim; Hyo Won Eun; Young Jae Kim; Jeong Min Lee; Joon Koo Han; Byung-Ihn Choi
Journal:  Eur Radiol       Date:  2015-08-08       Impact factor: 5.315

View more