In vivo quantification of bone mineral density of lumbar vertebrae using fast kVp switching dual-energy CT: correlation with quantitative computed tomography.

Shuwei Zhou1,2, Lu Zhu3, Tian You1, Ping Li1, Hongrong Shen1, Yewen He1, Hui Gao1, Luyou Yan1, Zhuo He1, Ying Guo1, Yaxi Zhang1, Kun Zhang1,2.   

Abstract

BACKGROUND: Osteoporosis is a common, progressive disease related to low bone mineral density (BMD). If it can be diagnosed at an early stage, osteoporosis is treatable. Quantitative computed tomography (QCT) is one of the current reference standards of BMD measurement, but dual-energy computed tomography (DECT) is considered to be a potential alternative. This study aimed to evaluate the feasibility and accuracy of phantomless in vivo DECT-based BMD quantification in comparison with QCT.
METHODS: A total of 128 consecutive participants who underwent DECT lumbar examinations between July 2018 and February 2019 were retrospectively analyzed. The density of calcium (water), hydroxyapatite (water), calcium (fat), and hydroxyapatite (fat) [DCa(Wa), DHAP(Wa), DCa(Fat) and DHAP(Fat), respectively] were measured along with BMD in the trabecular bone of lumbar level 1-2 by DECT and QCT. Linear regression analysis was performed to assess the relationship between DECT- and QCT-derived BMD at both the participant level and the vertebral level. Linear regression models were quantitatively evaluated with adjusted R-square, normalized mean squared error (NMSE) and relative error (RE). Bland-Altman analysis was conducted to assess agreement between measurements. P<0.05 was considered statistically significant.
RESULTS: Strong correlations were observed between DECT- and QCT-derived BMD at both the participant level and the vertebral level (adjusted R2 =0.983-0.987; NMSE = 1.6-2.1%; RElinear =0.6-0.9%). Bland-Altman plots indicated high agreement between both measurements. DCa(Fat) and DHAP(Fat) showed relatively similar and optimal predictive capability for QCT-derived BMD (both: adjusted R2 =0.987, NMSE =1.6%, RElinear =0.6%).
CONCLUSIONS: Fast kVp switching DECT enabled accurate phantomless in vivo BMD quantification of the lumbar spine. DCa(Fat) and DHAP(Fat) had relatively similar and optimal predictive capability. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Bone density; X-ray computed; lumbar vertebrae; osteoporosis; tomography

Year:  2021        PMID: 33392033      PMCID: PMC7719923          DOI: 10.21037/qims-20-367

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  34 in total

1.  Quantification of liver fat in the presence of iron and iodine: an ex-vivo dual-energy CT study.

Authors:  Michael A Fischer; Ralph Gnannt; Dimitri Raptis; Caecilia S Reiner; Pierre-Alain Clavien; Bernhard Schmidt; Sebastian Leschka; Hatem Alkadhi; Robert Goetti
Journal:  Invest Radiol       Date:  2011-06       Impact factor: 6.016

2.  Differential diagnosis of osteoblastic metastases from bone islands in patients with lung cancer by single-source dual-energy CT: advantages of spectral CT imaging.

Authors:  Yue Dong; Shaowei Zheng; Haruhiko Machida; Bing Wang; Ailian Liu; Yijun Liu; Xin Zhang
Journal:  Eur J Radiol       Date:  2015-01-24       Impact factor: 3.528

3.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

4.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT.

Authors:  Kazuhiro Matsumoto; Masahiro Jinzaki; Yutaka Tanami; Akihisa Ueno; Minoru Yamada; Sachio Kuribayashi
Journal:  Radiology       Date:  2011-02-17       Impact factor: 11.105

5.  Dual-energy CT-based assessment of the trabecular bone in vertebrae.

Authors:  S Wesarg; M Kirschner; M Becker; M Erdt; K Kafchitsas; M F Khan
Journal:  Methods Inf Med       Date:  2012-09-28       Impact factor: 2.176

6.  Differentiation of osteolytic metastases and Schmorl's nodes in cancer patients using dual-energy CT: advantage of spectral CT imaging.

Authors:  Shaowei Zheng; Yue Dong; Yanwei Miao; Ailian Liu; Xin Zhang; Bin Wang; Ying Ge; Yijun Liu; Shaowu Wang
Journal:  Eur J Radiol       Date:  2014-02-14       Impact factor: 3.528

7.  The global burden attributable to low bone mineral density.

Authors:  L Sànchez-Riera; E Carnahan; T Vos; L Veerman; R Norman; S S Lim; D Hoy; E Smith; N Wilson; J M Nolla; J S Chen; M Macara; N Kamalaraj; Y Li; C Kok; C Santos-Hernández; L March
Journal:  Ann Rheum Dis       Date:  2014-04-01       Impact factor: 19.103

8.  The study protocol for the China Health Big Data (China Biobank) project.

Authors:  Yan Wu; Zhe Guo; Xiaoxia Fu; Jing Wu; Jianbo Gao; Qiang Zeng; Haihong Fu; Xiaoguang Cheng
Journal:  Quant Imaging Med Surg       Date:  2019-06

9.  Evaluation of bone mineral density of the lumbar spine using a novel phantomless dual-energy CT post-processing algorithm in comparison with dual-energy X-ray absorptiometry.

Authors:  Christian Booz; Philipp C Hofmann; Martin Sedlmair; Thomas G Flohr; Bernhard Schmidt; Tommaso D'Angelo; Simon S Martin; Lukas Lenga; Doris Leithner; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol Exp       Date:  2017-09-20

10.  Perfusion-ventilation CT via three-material differentiation in dual-layer CT: a feasibility study.

Authors:  Andreas P Sauter; Johannes Hammel; Sebastian Ehn; Klaus Achterhold; Felix K Kopp; Melanie A Kimm; Kai Mei; Alexis Laugerette; Franz Pfeiffer; Ernst J Rummeny; Daniela Pfeiffer; Peter B Noël
Journal:  Sci Rep       Date:  2019-04-09       Impact factor: 4.379

View more
  3 in total

1.  Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research.

Authors:  Mingyue Wang; Yan Wu; Yue Zhou; Junqiang Dong; Shenshen Hu; Ping Hou; Jianbo Gao
Journal:  Int J Gen Med       Date:  2022-08-29

2.  Accuracy and precision of volumetric bone mineral density assessment using dual-source dual-energy versus quantitative CT: a phantom study.

Authors:  Vitali Koch; Nils Große Hokamp; Moritz H Albrecht; Leon D Gruenewald; Ibrahim Yel; Jan Borggrefe; Stefan Wesarg; Katrin Eichler; Iris Burck; Tatjana Gruber-Rouh; Lukas Lenga; Thomas J Vogl; Simon S Martin; Julian L Wichmann; Renate M Hammerstingl; Leona S Alizadeh; Christoph Mader; Nicole A Huizinga; Tommaso D'Angelo; Giorgio Ascenti; Silvio Mazziotti; Christian Booz
Journal:  Eur Radiol Exp       Date:  2021-10-05

3.  Osteoporosis and Endplate Damage Correlation Using a Combined Approach of Hounsfield Unit Values and Total Endplate Scores: A Retrospective Cross-Sectional Study.

Authors:  Chenyang Zhuang; Zixiang Wang; Weisin Chen; Bo Tian; Juan Li; Hong Lin
Journal:  Clin Interv Aging       Date:  2021-07-05       Impact factor: 4.458

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.