Encapsulation Approaches for In-Stent Wireless Magnetoelastic Sensors.

Jiqing Jiang, Ramprasad Mohanan Nambisan, Scott Green, Yogesh B Gianchandani.   

Abstract

Wireless magnetoelastic sensors offer significant potential for measuring the accumulation of biomass within stents - enabling early detection prior to stent occlusion - but the encapsulation of these sensors remains a critical challenge. The encapsulation must allow the sensors to navigate the curvature and accommodate the contact forces imparted during and after the implantation procedure, while also leaving the sensor open to mechanical interaction with the biomass during the extended period of deployment. This paper is focused on the encapsulation of ribbon-like magnetoelastic sensors (12.5 mm x 1 mm x 60 μm) within plastic biliary stents (inner diameter of 2.54 mm). The compromise between two polymer-based package designs - one mechanically flexible (Type F) and one mechanically stiff (Type S) - is evaluated. The primary advantage of the Type F package is the flexibility during the delivery process while that of the Type S package is in maintaining a strong signal even when the stent is in a curved bile duct. The maximum thicknesses of the Type F and S packages are 0.53 mm and 0.74 mm, respectively. Mechanical tests show that both types protect the sensors from forces imparted by a standard introducer, and allow the encapsulated sensors to accommodate bending with a radius of curvature as small as 3 cm. The Type F package has also been tested in situ, in the bile duct of a porcine carcass. The signal is measurable with a wireless range of 10 cm, at a resonant frequency of 159 kHz and a quality factor of 397.

Entities:  

Year:  2018        PMID: 30475708      PMCID: PMC6667316          DOI: 10.1109/TBME.2018.2882415

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  14 in total

1.  Cardiology patient page. Restenosis: repeat narrowing of a coronary artery: prevention and treatment.

Authors:  George Dangas; Frank Kuepper
Journal:  Circulation       Date:  2002-06-04       Impact factor: 29.690

Review 2.  Coronary-artery stents.

Authors:  Patrick W Serruys; Michael J B Kutryk; Andrew T L Ong
Journal:  N Engl J Med       Date:  2006-02-02       Impact factor: 91.245

3.  Retrograde ureteral stents for extrinsic ureteral obstruction: nine years' experience at University of Michigan.

Authors:  Henry M Rosevear; Simon P Kim; David L Wenzler; Gary J Faerber; William W Roberts; J Stuart Wolf
Journal:  Urology       Date:  2007-11       Impact factor: 2.649

Review 4.  The role of transjugular intrahepatic portosystemic shunt (TIPS) in the management of portal hypertension.

Authors:  Luis Colombato
Journal:  J Clin Gastroenterol       Date:  2007 Nov-Dec       Impact factor: 3.062

Review 5.  Plastic biliary stent occlusion: factors involved and possible preventive approaches.

Authors:  Gianfranco Donelli; Emilio Guaglianone; Roberta Di Rosa; Fausto Fiocca; Antonio Basoli
Journal:  Clin Med Res       Date:  2007-03

Review 6.  Endoscopic therapy of benign biliary strictures.

Authors:  Joel R Judah; Peter V Draganov
Journal:  World J Gastroenterol       Date:  2007-07-14       Impact factor: 5.742

Review 7.  3D printed microfluidic devices: enablers and barriers.

Authors:  Sidra Waheed; Joan M Cabot; Niall P Macdonald; Trevor Lewis; Rosanne M Guijt; Brett Paull; Michael C Breadmore
Journal:  Lab Chip       Date:  2016-05-24       Impact factor: 6.799

8.  3D printed microfluidic circuitry via multijet-based additive manufacturing.

Authors:  R D Sochol; E Sweet; C C Glick; S Venkatesh; A Avetisyan; K F Ekman; A Raulinaitis; A Tsai; A Wienkers; K Korner; K Hanson; A Long; B J Hightower; G Slatton; D C Burnett; T L Massey; K Iwai; L P Lee; K S J Pister; L Lin
Journal:  Lab Chip       Date:  2016-01-04       Impact factor: 6.799

9.  Nonoperative imaging techniques in suspected biliary tract obstruction.

Authors:  Frances Tse; Jeffrey S Barkun; Joseph Romagnuolo; Gad Friedman; Jeffrey D Bornstein; Alan N Barkun
Journal:  HPB (Oxford)       Date:  2006       Impact factor: 3.647

10.  In vivo and in situ evaluation of a wireless magnetoelastic sensor array for plastic biliary stent monitoring.

Authors:  Scott R Green; Richard S Kwon; Grace H Elta; Yogesh B Gianchandani
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.