Oscillometric and Doppler arterial blood pressure measurement in conscious goats.

Olga Szaluś-Jordanow1, Michał Czopowicz1, Anna Świerk1, Oktawia Szpinda1, Magdalena Garncarz1, Marcin Mickiewicz1, Agata Moroz1, Emilia Bagnicka1, Jarosław Kaba1.   

Abstract

The objective of this study was to characterize arterial blood pressure (BP) measurements obtained by using 2 indirect methods, oscillometry and Doppler ultrasonic sphygmomanometry, in conscious goats. Agreement between systolic BP yielded by these 2 methods was then assessed. Sixty female dairy goats aged from 1.5 to 11.8 y (median: 5.5 y) were examined in a standing position with a cuff placed on the tail. All goats had a severe arthritic form of caprine arthritis-encephalitis. Three to 5 repeated measurements of each BP type were averaged for each goat and considered as a final measurement. With oscillometry, systolic blood pressure (O-SBP), diastolic blood pressure, and mean blood pressure, as well as heart rate (HR) were measured, while only systolic blood pressure was measured with Doppler (D-SBP). The O-SBP did not correlate with D-SBP [correlation coefficient (r) = 0.24, P = 0.067]; the mean difference (± standard deviation) was 24.5 ± 26.3 mmHg and limits of agreement were from -27.2 mmHg [95% confidence interval (CI): -39.0, -15.4 mmHg] to 76.1 mmHg (95% CI: 64.3, 87.9 mmHg). No significant linear correlation was found between any BPs and HR (r: -0.10 to 0.22) or age (r: -0.26 to 0.07) of the goats. The study showed that, while BP could be measured in conscious goats using both oscillometry and Doppler ultrasonic sphygmomanometry, the results obtained were so inconsistent that these methods could not be used interchangeably.

Entities:  

Mesh:

Year:  2018        PMID: 30363283      PMCID: PMC6168019     

Source DB:  PubMed          Journal:  Can J Vet Res        ISSN: 0830-9000            Impact factor:   1.310


  25 in total

1.  Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats.

Authors:  Karen M Pedersen; Michael A Butler; Annette K Ersbøll; Henrik D Pedersen
Journal:  J Am Vet Med Assoc       Date:  2002-09-01       Impact factor: 1.936

2.  Accuracy of an oscillometric blood pressure monitor during phenylephrine-induced hypertension in dogs.

Authors:  Rose M McMurphy; Melissa R Stoll; Raymond McCubrey
Journal:  Am J Vet Res       Date:  2006-09       Impact factor: 1.156

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Indirect Doppler ultrasonic measurement of arterial blood pressure results in a large measurement error in dorsally recumbent anaesthetised horses.

Authors:  J E Bailey; C I Dunlop; P L Chapman; W C Demme; S L Allen; R B Heath; K T Crump; C S Golden; A E Wagner
Journal:  Equine Vet J       Date:  1994-01       Impact factor: 2.888

5.  Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home.

Authors:  A J Kallet; L D Cowgill; P H Kass
Journal:  J Am Vet Med Assoc       Date:  1997-03-01       Impact factor: 1.936

6.  Epidemiological study of blood pressure in domestic cats.

Authors:  A R Bodey; J Sansom
Journal:  J Small Anim Pract       Date:  1998-12       Impact factor: 1.522

7.  Non-invasive measurement of arterial blood pressure in dogs: a potential indicator for the identification of stress.

Authors:  I C Vincent; A R Michell; R A Leahy
Journal:  Res Vet Sci       Date:  1993-03       Impact factor: 2.534

8.  Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized sheep, goats, and cattle.

Authors:  Turi K Aarnes; John Ae Hubbell; Phillip Lerche; Richard M Bednarski
Journal:  Vet Anaesth Analg       Date:  2013-11-14       Impact factor: 1.648

9.  Measuring level of agreement between values obtained by directly measured blood pressure and ultrasonic Doppler flow detector in cats.

Authors:  Anderson F da Cunha; Katrin Saile; Hugues Beaufrère; Wendy Wolfson; Diana Seaton; Mark J Acierno
Journal:  J Vet Emerg Crit Care (San Antonio)       Date:  2014-04-03

Review 10.  Hypertension 2008--awareness, understanding, and treatment of previously diagnosed hypertension in baby boomers and seniors: a survey conducted by Harris interactive on behalf of the Preventive Cardiovascular Nurses Association.

Authors:  Nancy H Miller; Kathy Berra; Janet Long
Journal:  J Clin Hypertens (Greenwich)       Date:  2010-05       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.