Literature DB >> 12216901

Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats.

Karen M Pedersen, Michael A Butler, Annette K Ersbøll, Henrik D Pedersen.   

Abstract

OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats.
DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared.
RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.

Entities:  

Mesh:

Year:  2002        PMID: 12216901     DOI: 10.2460/javma.2002.221.646

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  11 in total

1.  Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs.

Authors:  Paul D MacFarlane; Nicola Grint; Alexandra Dugdale
Journal:  Vet Res Commun       Date:  2010-03-23       Impact factor: 2.459

2.  Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs.

Authors:  Christopher E Haberman; Chang W Kang; Jefferson D Morgan; Scott A Brown
Journal:  Can J Vet Res       Date:  2006-07       Impact factor: 1.310

3.  Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

Authors:  Turi K Aarnes; John A E Hubbell; Phillip Lerche; Richard M Bednarski
Journal:  Can Vet J       Date:  2012-08       Impact factor: 1.008

4.  Comparison of telemetry and high-definition oscillometry for blood pressure measurements in conscious dogs: effects of torcetrapib.

Authors:  Olivier Meyer; Roland Jenni; Andrea Greiter-Wilke; Alexander Breidenbach; Henry H Holzgrefe
Journal:  J Am Assoc Lab Anim Sci       Date:  2010-07       Impact factor: 1.232

5.  Efficacy of preanesthetic intramuscular administration of ephedrine for prevention of anesthesia-induced hypotension in cats and dogs.

Authors:  Christine Egger; Mary-Ann McCrackin; Erik Hofmeister; Gwenola Touzot-Jourde; Bart Rohrbach
Journal:  Can Vet J       Date:  2009-02       Impact factor: 1.008

6.  Oscillometric and Doppler arterial blood pressure measurement in conscious goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Anna Świerk; Oktawia Szpinda; Magdalena Garncarz; Marcin Mickiewicz; Agata Moroz; Emilia Bagnicka; Jarosław Kaba
Journal:  Can J Vet Res       Date:  2018-10       Impact factor: 1.310

7.  Sedative effects of intramuscular alfaxalone administered to cats.

Authors:  Jun Tamura; Tomohito Ishizuka; Sho Fukui; Norihiko Oyama; Kodai Kawase; Takaharu Itami; Kenjiro Miyoshi; Tadashi Sano; Kirby Pasloske; Kazuto Yamashita
Journal:  J Vet Med Sci       Date:  2015-03-19       Impact factor: 1.267

8.  Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Agata Moroz; Marcin Mickiewicz; Magdalena Garncarz; Emilia Bagnicka; Tadeusz Frymus; Jarosław Kaba
Journal:  PLoS One       Date:  2018-05-23       Impact factor: 3.240

9.  Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats.

Authors:  Petra Cerna; Panos E Archontakis; Hester Ok Cheuk; Danièlle A Gunn-Moore
Journal:  J Feline Med Surg       Date:  2020-06-25       Impact factor: 2.015

10.  Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography.

Authors:  Yasuhiro Heishima; Yasutomo Hori; Seishiro Chikazawa; Kazutaka Kanai; Fumio Hoshi; Naoyuki Itoh
Journal:  J Vet Med Sci       Date:  2016-03-18       Impact factor: 1.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.