Literature DB >> 30233935

Patient-Matched Implementation for Reverse Total Shoulder Arthroplasty.

Olivier Verborgt1,2, Geert Declercq1, Philippe Hardy3.   

Abstract

INTRODUCTION: Three-dimensional (3D) preoperative planning and patient-specific instrumentation (PSI) improve accuracy of glenoid component implantation in reverse shoulder arthroplasty. STEP 1 PREOPERATIVE VIRTUAL 3D PLANNING VIDEO 1: Use a 3D software tool for virtual preoperative planning of glenoid component implantation. STEP 2 PATIENT POSITIONING AND SURGICAL APPROACH VIDEO 2: Place the patient in a semi-beach-chair position and perform a standard deltopectoral approach. STEP 3 HUMERAL PREPARATION VIDEO 3: Prepare the humeral side for implantation of the humeral component using standard instrumentation. STEP 4 GLENOID EXPOSURE AND PREPARATION VIDEO 4: Expose the glenoid and prepare the glenoid surface for component implantation. STEP 5 GLENOID PREPARATION AND IMPLANTATION OF THE GLENOID BASEPLATE USING 4 PSI GUIDES VIDEO 5: Use the 4 PSI guides to prepare the glenoid for component implantation according to the preoperative plan. STEP 6 DEFINITIVE IMPLANTATION OF THE COMPONENTS AND REDUCTION VIDEO 6: Implant the glenosphere and humeral component and reduce the prosthesis. STEP 7 POSTOPERATIVE REHABILITATION PROTOCOL: Start passive and active-assisted exercises immediately, and begin muscle strengthening and active exercises at 6 weeks.
RESULTS: A recent prospective, comparative study assessed the influence of 3D preoperative planning and PSI guidance of glenoid component positioning in total shoulder arthroplasty and reverse shoulder arthroplasty18.

Entities:  

Year:  2016        PMID: 30233935      PMCID: PMC6132615          DOI: 10.2106/JBJS.ST.16.00070

Source DB:  PubMed          Journal:  JBJS Essent Surg Tech        ISSN: 2160-2204


  21 in total

1.  The effect of component positioning on intrinsic stability of the reverse shoulder arthroplasty.

Authors:  Philippe Favre; Patrick S Sussmann; Christian Gerber
Journal:  J Shoulder Elbow Surg       Date:  2010-03-23       Impact factor: 3.019

2.  Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation.

Authors:  Olivier Verborgt; Thomas De Smedt; Matthias Vanhees; Stefan Clockaerts; Paul M Parizel; Francis Van Glabbeek
Journal:  J Shoulder Elbow Surg       Date:  2011-01       Impact factor: 3.019

3.  Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in-vitro randomized controlled trial.

Authors:  Duong Nguyen; Louis M Ferreira; James R Brownhill; Graham J W King; Darren S Drosdowech; Kenneth J Faber; James A Johnson
Journal:  J Shoulder Elbow Surg       Date:  2009-05-30       Impact factor: 3.019

Review 4.  Reverse total shoulder arthroplasty.

Authors:  Christian Gerber; Scott D Pennington; Richard W Nyffeler
Journal:  J Am Acad Orthop Surg       Date:  2009-05       Impact factor: 3.020

5.  Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part Two: The three-column concept.

Authors:  C Scott Humphrey; James D Kelly; Tom R Norris
Journal:  J Shoulder Elbow Surg       Date:  2008-06-09       Impact factor: 3.019

6.  Effects of tilt and glenosphere eccentricity on baseplate/bone interface forces in a computational model, validated by a mechanical model, of reverse shoulder arthroplasty.

Authors:  Sergio Gutiérrez; Matthew Walker; Matthew Willis; Derek R Pupello; Mark A Frankle
Journal:  J Shoulder Elbow Surg       Date:  2011-02-02       Impact factor: 3.019

7.  Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis.

Authors:  C M L Werner; P A Steinmann; M Gilbart; C Gerber
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

8.  Initial glenoid component fixation in "reverse" total shoulder arthroplasty: a biomechanical evaluation.

Authors:  Melinda Harman; Mark Frankle; Matt Vasey; Scott Banks
Journal:  J Shoulder Elbow Surg       Date:  2005 Jan-Feb       Impact factor: 3.019

9.  Scapular notching in reverse shoulder arthroplasty: is it important to avoid it and how?

Authors:  Christophe Lévigne; Jérome Garret; Pascal Boileau; Ghassan Alami; Luc Favard; Gilles Walch
Journal:  Clin Orthop Relat Res       Date:  2011-09       Impact factor: 4.176

10.  Scapular notching in reverse shoulder arthroplasty.

Authors:  Christophe Lévigne; Pascal Boileau; Luc Favard; Pascal Garaud; Daniel Molé; François Sirveaux; Gilles Walch
Journal:  J Shoulder Elbow Surg       Date:  2008-06-16       Impact factor: 3.019

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.