Literature DB >> 19482490

Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in-vitro randomized controlled trial.

Duong Nguyen1, Louis M Ferreira, James R Brownhill, Graham J W King, Darren S Drosdowech, Kenneth J Faber, James A Johnson.   

Abstract

BACKGROUND: Glenoid replacement is challenging due to the difficult joint exposure and visualization of anatomical reference landmarks. Improper positioning of the glenoid component or inadequate correction of the retroversion using currently available instrumentation may lead to early failure. The objective of this study was to evaluate a computer-assisted technique to achieve a more accurate placement of the glenoid component compared to traditional techniques.
METHODS: Sixteen paired cadaveric shoulders were randomized to either traditional or computer-assisted glenoid implantation. Preoperative planning consisting of CT scanning with 3-dimensional image modeling of the shoulder specimens and intraoperative tracking with real-time feedback provided to the surgeon was employed in the computer-assisted group. A validated, previously published, standardized protocol for tracking the orientation of the glenoid in space using 3 glenoid surface landmarks was employed. All phases of glenoid implantation (initial guide pin insertion, reaming, drilling of the peg holes, and final component implantation) were tracked and recorded by the computer. A post-implantation CT scan was performed in both groups to compare how accurately the implants were placed.
RESULTS: The computer-assisted technique was more accurate in achieving the correct version during all phases of glenoid implantation and as measured on the post-implantation CT scan (P < .05). The largest errors with traditional glenoid implantation were observed during drilling and, more so, during reaming. The trend was to overly retrovert the glenoid.
CONCLUSIONS: Computer assisted navigation results in a more accurate glenoid component placement relative to traditional techniques. LEVEL OF EVIDENCE: Basic Science Study.

Entities:  

Mesh:

Year:  2009        PMID: 19482490     DOI: 10.1016/j.jse.2009.02.022

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  19 in total

1.  Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty.

Authors:  Eduardo M Suero; Musa Citak; Darrick Lo; Aaron J Krych; Edward V Craig; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-30       Impact factor: 4.342

2.  Development of a vibration haptic simulator for shoulder arthroplasty.

Authors:  Jonathan R Kusins; Jason A Strelzow; Marie-Eve LeBel; Louis M Ferreira
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-17       Impact factor: 2.924

3.  Anatomical plane and transverse axis of the scapula: Reliability of manual positioning of the anatomical landmarks.

Authors:  Adrien Jacquot; Marc-Olivier Gauci; Manuel Urvoy; François Boux de Casson; Julien Berhouet; Hoel Letissier
Journal:  Shoulder Elbow       Date:  2021-03-17

4.  Proper benefit of a three dimensional pre-operative planning software for glenoid component positioning in total shoulder arthroplasty.

Authors:  Adrien Jacquot; Marc-Olivier Gauci; Jean Chaoui; Mohammed Baba; Pierric Deransart; Pascal Boileau; Daniel Mole; Gilles Walch
Journal:  Int Orthop       Date:  2018-07-02       Impact factor: 3.075

Review 5.  Glenoid component positioning and guidance techniques in anatomic and reverse total shoulder arthroplasty: A systematic review and meta-analysis.

Authors:  David M Burns; Tym Frank; Cari M Whyne; Patrick Dg Henry
Journal:  Shoulder Elbow       Date:  2018-10-26

6.  Patient-Matched Implementation for Reverse Total Shoulder Arthroplasty.

Authors:  Olivier Verborgt; Geert Declercq; Philippe Hardy
Journal:  JBJS Essent Surg Tech       Date:  2016-12-28

7.  Can an extracorporeal glenoid aiming device be used to optimize the position of the glenoid component in total shoulder arthroplasty?

Authors:  Tom R G M Verstraeten; Bart Berghs; Alexander Van Tongel; David Volders; Lieven F De Wilde
Journal:  Int J Shoulder Surg       Date:  2015 Oct-Dec

8.  Total shoulder arthroplasty does not correct the orientation of the eroded glenoid.

Authors:  Thomas Gregory; Ulrich Hansen; Roger Emery; Andrew A Amis; Celine Mutchler; Fabienne Taillieu; Bernard Augereau
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

9.  Consequences of reaming with flat and convex reamers for bone volume and surface area of the glenoid; a basic science study.

Authors:  Anne Karelse; Steven Leuridan; Alexander Van Tongel; Philippe Debeer; Jos Van Der Sloten; Kathleen Denis; Lieven F De Wilde
Journal:  J Orthop Surg Res       Date:  2015-11-25       Impact factor: 2.359

10.  Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty.

Authors:  Richard James Dallalana; Ryan A McMahon; Ben East; Liam Geraghty
Journal:  Int J Shoulder Surg       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.