Literature DB >> 30221010

Improving Edge Crystal Identification in Flood Histograms Using Triangular Shape Crystals.

Peng Peng1, Chih-Chieh Liu1, Junwei Du1, Xiaowei Bai1, Simon R Cherry1.   

Abstract

This work presents a method to improve the separation of edge crystals in PET block detectors. As an alternative to square-shaped crystal arrays, we used an array of triangular-shaped crystals. This increases the distance between the crystal centres at the detector edges potentially improving the separation of edge crystals. To test this design, we have compared the flood histograms of two 4×4 scintillator arrays in both square and triangular configurations. The quality of the flood histogram was quantified using the fraction of events positioned in the correct crystal based on a 2D Gaussian fit of the segmented flood histograms. In the first study, the two crystal arrays were coupled with the SiPM directly using optical grease, and the flood histogram quality for the edge and corner crystals in the triangular-shaped array were much better than that for those crystals in the square-shaped array. The average light collection efficiency for the triangular-shaped array was 5.9% higher than that for the square-shaped array. The average energy resolution for the triangular and square shape array were 11.6% and 13.2% respectively. In the second study, two light guides with thickness 1 mm and 2 mm were used between the crystal arrays and the SiPM. The thicker lightguide degraded the light collection efficiency and energy resolution due to the light loss introduced by the light guide. However, in the 2-mm thick lightguide case, the flood histogram quality for the edge and corner crystals in the square-shaped array were improved due to better separation of those crystals in the flood histogram. Comparing the performance of the two crystal arrays with three different light guides, the triangular-shaped crystal array with no lightguide gave the best performance.

Entities:  

Keywords:  Detector positioning; Flood histogram; PET

Year:  2018        PMID: 30221010      PMCID: PMC6136832          DOI: 10.1088/2057-1976/aaaa84

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  10 in total

1.  Detector development for microPET II: a 1 microl resolution PET scanner for small animal imaging.

Authors:  A Chatziioannou; Y C Tai; N Doshi; S R Cherry
Journal:  Phys Med Biol       Date:  2001-11       Impact factor: 3.609

Review 2.  In vivo molecular and genomic imaging: new challenges for imaging physics.

Authors:  Simon R Cherry
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

3.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

4.  Light sharing in multi-flat-panel-PMT PEM detectors.

Authors:  Raymond R Raylman; Stan Majewski; Michael R Mayhugh
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

Review 5.  Focus on time-of-flight PET: the benefits of improved time resolution.

Authors:  Maurizio Conti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-13       Impact factor: 9.236

6.  Fundamental Limits of Spatial Resolution in PET.

Authors:  William W Moses
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-08-21       Impact factor: 1.455

7.  A Simple Capacitive Charge-Division Readout for Position-Sensitive Solid-State Photomultiplier Arrays.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

8.  NEMA NU 4-2008 comparison of preclinical PET imaging systems.

Authors:  Andrew L Goertzen; Qinan Bao; Mélanie Bergeron; Eric Blankemeyer; Stephan Blinder; Mario Cañadas; Arion F Chatziioannou; Katherine Dinelle; Esmat Elhami; Hans-Sonke Jans; Eduardo Lage; Roger Lecomte; Vesna Sossi; Suleman Surti; Yuan-Chuan Tai; Juan José Vaquero; Esther Vicente; Darin A Williams; Richard Laforest
Journal:  J Nucl Med       Date:  2012-06-14       Impact factor: 10.057

Review 9.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

10.  Characterization of Large-Area SiPM Array for PET Applications.

Authors:  Junwei Du; Yongfeng Yang; Xiaowei Bai; Martin S Judenhofer; Eric Berg; Kun Di; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.