Matthias C Schulz1, Lena Rittmann2, Ursula Range3, Günter Lauer4, Dominik Haim5.
Abstract
Implant dentistry is a growing field in the education of undergraduate dental students. The present laboratory study evaluates factors which may potentially influence the accuracy of free-hand implant insertion and the use of an orientation template. After three-dimensional planning using coDiagnostiXTM, orientation templates, including sleeves for the pilot-drill in regions 41 and 45, were manufactured by thermoforming. Sixty-one fifth year dental students inserted one implant using the orientation template and another implant free-hand in an artificial mandible. Information regarding age, sex, handedness, education, and the time required for implant insertion were recorded. Subsequently, the mandibles were scanned using cone-beam-computed tomography and the accuracy of the implant position was assessed, while statistical analysis followed. The free-hand implant insertion resulted in a distal deviation of -1.34 ± 5.15° and a mesial mismatch of 0.06 ± 0.79 mm at the artificial bone level compared to the sleeves. When using the orientation templates, the deviation decreased to -0.67 ± 3.48° and a distal mismatch of -0.22 ± 0.62 mm was achieved. The difference was statistically significant for the mismatch (p < 0.049). Regarding the limitations of our study, it could be said that the accuracy level achieved by dental undergraduates using implant placement with orientation templates is comparable to that in other studies.Entities:
Keywords: dental education; dental implants; free-hand implant insertion; orientation template; thermoforming
Year: 2018 PMID: 30200450 PMCID: PMC6162789 DOI: 10.3390/dj6030043
Source DB: PubMed Journal: Dent J (Basel) ISSN: 2304-6767
Figure 1Orientation template fixed on the mandibular model. The pilot cavity in the region of tooth 45 was performed with a 2.0 mm pilot drill.
Figure 2Two-dimensional schematic drawing of the measurements. The angle α between the median axis of the sleeve (s) and the median axis of the implant (i) was measured. Furthermore, the mismatch (d) between the planned median axis of the sleeve (s) and the median axis of the implant (i) was assessed at the bone level (bl). All measurements were likewise performed in the oro-vestibular and mesio-distal direction.
Demographical data of the participants in regard to age, gender, and handedness. Furthermore, optionally professional training in the group of the dental students is listed (man.—manual; req.—required). In cases where no specification was made by the student, it was marked as “not stated”.
| Parameter | Group | Dental Students |
|---|---|---|
| age | 18–30 years | 54 |
| > 30 years | 7 | |
| gender | female | 40 |
| male | 15 | |
| not stated | 6 | |
| handedness | left | 5 |
| right | 50 | |
| not stated | 6 | |
| professional education before dental school | yes | 15 |
| no | 38 | |
| not stated | 8 | |
| type of professional training | high man. fine motor skills | 4 |
| medium man. fine motor skills | 7 | |
| no man. fine motor skills req. | 4 |
Pair-wise comparison of the parameters between the use of the orientation template and free-hand implant insertion. The mean values, median values, standard deviations of the mean values (SD), and the p-values are depicted. A “+” means a deviation in mesial or oral direction. A “−“ refers to a deviation in distal or vestibular direction. Statistically significant differences are marked in bold font.
| Parameter | Group | Mean | ± SD | Median | Min | Max | |
|---|---|---|---|---|---|---|---|
| distance implant shoulder/ | orientation template | 0.57 | 0.36 | 0.53 | −0.29 | 1.70 | 0.004 |
| bone in mm | free-hand | 0.41 | 0.43 | 0.38 | −0.96 | 1.60 | |
| deviation implant/sleeve | orientation template | −0.67 | 3.48 | 0.14 | −12.14 | 7.26 | 0.304 |
| mes-dis in degrees | free-hand | −1.34 | 5.15 | −0.17 | −10.21 | 9.36 | |
| deviation implant/sleeve | orientation template | 2.28 | 2.75 | 2.45 | −3.79 | 10.83 | 0.057 |
| oro-ves in degrees | free-hand | 0.71 | 3.99 | 0.83 | −14.52 | 15.10 | |
| mismatch implant/sleeve | orientation template | −0.22 | 0.62 | −0.33 | −1.62 | 1.23 | 0.049 |
| mes-dis in mm | free-hand | 0.06 | 0.79 | 0.31 | −1.85 | 1.12 | |
| mismatch implant/sleeve | orientation template | 0.24 | 0.62 | 0.31 | −1.89 | 1.17 | <0.001 |
| oro-ves in mm | free-hand | −1.08 | 0.55 | −1.13 | −2.10 | 0.81 | |
| deviation of parallel axis | orientation template | 5.49 | 3.34 | 5.21 | 0.36 | 12.14 | <0.001 |
| tooth/implant in degrees | free-hand | 2.01 | 2.41 | 1.20 | 0.07 | 15.45 | |
| time attended for implant | orientation template | 9.04 | 4.63 | 8.00 | 1 | 25 | 0.217 |
| insertion in minutes | free-hand | 9.41 | 3.77 | 9.00 | 3 | 20 |