Literature DB >> 22551385

Accuracy of full guided vs. half-guided implant surgery.

S Kühl1, S Zürcher, T Mahid, M Müller-Gerbl, A Filippi, P Cattin.   

Abstract

OBJECTIVES: The benefit in terms of higher accuracy for full guided implant surgery (template based guided cavity preparation and guided implant insertion) compared with half-guided surgery (template based guided cavity preparation and free-handed, manual implant insertion) has not been proved till now.
MATERIAL AND METHODS: A total of 38 identical implants were inserted into five human cadaver jaws, after virtual implant planning with the coDiagnostiX(™) device. All cavities were drilled using templates equipped with tubes for guidance. At random, 19 implants were inserted in a free handed way (half-guided), whereas 19 implants were inserted in a guided way through the templates tubes (full guided). Postoperative cone beam computer tomographies (CBCT) were performed, and based on image fusion the total deviations between the virtual implant positions at the implants base and tip were determined and compared between both implantation modi.
RESULTS: The mean difference in accuracy between both implantation modalities at the implants bases was 0.72 mm (range: 0.16-1.17 mm, SD: 0.45). The mean difference in accuracy between both modalities at the implants tips was 0.46 mm (range: 0.16-1.23 mm. SD: 0.49). Although full guided implantation showed a generally higher accuracy (mean tip: 1.54 mm, range: 0.33-3.64 mm; mean base: 1.52 mm, range: 0.4-3.54 mm) than half-guided implantation (mean tip: 1.84 mm, range: 0.84-3.22 mm; mean base: 1.56 mm, range: 0.49-3.43 mm), the differences were not statistically significant.
CONCLUSIONS: The accuracy of half-guided implant surgery is comparable with full guided implant surgery.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22551385     DOI: 10.1111/j.1600-0501.2012.02484.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

1.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

2.  Accuracy of half-guided implant placement with machine-driven or manual insertion: a prospective, randomized clinical study.

Authors:  Kristof Orban; Endre Varga; Peter Windisch; Gabor Braunitzer; Balint Molnar
Journal:  Clin Oral Investig       Date:  2021-08-16       Impact factor: 3.606

3.  The Use of Orientation Templates and Free-Hand Implant Insertion in Artificial Mandibles-An Experimental Laboratory Examination in Fifth-Year Dental Students.

Authors:  Matthias C Schulz; Lena Rittmann; Ursula Range; Günter Lauer; Dominik Haim
Journal:  Dent J (Basel)       Date:  2018-09-01

Review 4.  Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance.

Authors:  Emitis Natali Naeini; Mandana Atashkadeh; Hugo De Bruyn; Jan D'Haese
Journal:  Clin Implant Dent Relat Res       Date:  2020-05-13       Impact factor: 3.932

5.  Multivariate analysis of causal factors influencing accuracy of guided implant surgery for partial edentulism: a retrospective clinical study.

Authors:  Atsushi Matsumura; Tamaki Nakano; Shinji Ono; Akihiro Kaminaka; Hirofumi Yatani; Daijiro Kabata
Journal:  Int J Implant Dent       Date:  2021-04-19

6.  Comparative study of the accuracy of CBCT implant site measurements using different software programs.

Authors:  Asma'a A Al-Ekrish
Journal:  Saudi Dent J       Date:  2020-08-06

7.  Geometric Reproducibility of Three-Dimensional Oral Implant Planning Based on Magnetic Resonance Imaging and Cone-Beam Computed Tomography.

Authors:  Franz Sebastian Schwindling; Sophia Boehm; Christopher Herpel; Dorothea Kronsteiner; Lorenz Vogel; Alexander Juerchott; Sabine Heiland; Martin Bendszus; Peter Rammelsberg; Tim Hilgenfeld
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

8.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study.

Authors:  Takeshi Toyoshima; Hideaki Tanaka; Masanori Sasaki; Eiji Ichimaru; Yasushi Naito; Yasuyuki Matsushita; Kiyoshi Koyano; Seiji Nakamura
Journal:  Clin Exp Dent Res       Date:  2015-07-14

9.  Accuracy of computer-guided implantation in the placement of one-piece ceramic dental implants in the anterior region: A prospective clinical study.

Authors:  Nopparat Suksod; Chatchai Kunavisarut; Jira Kitisubkanchana
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

10.  Use of three points to determine the accuracy of guided implantation.

Authors:  Ye Liang; ShanShan Yuan; JingJing Huan; HuiXin Wang; YiYi Zhang; ChangYun Fang; Jia-Da Li
Journal:  PLoS One       Date:  2019-12-03       Impact factor: 3.240