Literature DB >> 28632253

Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies.

Fernando Bover-Ramos, José Viña-Almunia, Juan Cervera-Ballester, Miguel Peñarrocha-Diago, Berta García-Mira.   

Abstract

PURPOSE: The aim of this systematic review was to analyze the accuracy of implant placement using computer-guided surgery and to compare virtual treatment planning and outcome in relation to study type (in vitro, clinical, or cadaver). A further objective was to compare the accuracy of half-guided implant surgery with that of full-guided implant surgery.
MATERIALS AND METHODS: A PubMed search was performed to identify studies published between January 2005 and February 2015, searching the keywords "reliability AND dental implant planning" and "accuracy dental implant planning." Inclusion criteria were established a priori. Horizontal coronal deviation, horizontal apical deviation, angular deviation, and vertical deviation were analyzed.
RESULTS: A total of 186 articles were reviewed, and 34 fulfilled the inclusion criteria. Information about 3,033 implants was analyzed in 8 in vitro studies (543 implants), 4 cadaver studies (246 implants), and 22 clinical studies (2,244 implants). Significantly less horizontal apical deviation and angular deviation were observed in in vitro studies compared to clinical and cadaver studies, but there were no statistically significant differences in apical coronal deviation or vertical deviation between the groups. Compared to half-guided surgery, full-guided implant surgery showed significantly less horizontal coronal deviation for cadaver studies, significantly less horizontal apical deviation for clinical studies, and significantly less angular deviation for both clinical and cadaver studies.
CONCLUSION: Implant placement accuracy was lower in clinical and cadaver studies compared with in vitro studies, especially in terms of horizontal apical deviation and angular deviation. Full-guided implant surgery achieved greater accuracy than half-guided surgery.

Mesh:

Substances:

Year:  2017        PMID: 28632253     DOI: 10.11607/jomi.5556

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  30 in total

Review 1.  Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis.

Authors:  Adrià Jorba-García; Albert González-Barnadas; Octavi Camps-Font; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  Clin Oral Investig       Date:  2021-02-26       Impact factor: 3.573

2.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

3.  Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial.

Authors:  Cornelia Edelmann; Martin Wetzel; Anne Knipper; Ralph G Luthardt; Sigmar Schnutenhaus
Journal:  J Clin Med       Date:  2021-04-21       Impact factor: 4.241

Review 4.  Accuracy of computer-guided surgery for dental implant placement in fully edentulous patients: A systematic review.

Authors:  Daniel Amaral Alves Marlière; Maurício Silva Demètrio; Leonardo Santos Picinini; Rodrigo Guerra De Oliveira; Henrique Duque De Miranda Chaves Netto
Journal:  Eur J Dent       Date:  2018 Jan-Mar

5.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

6.  The Use of Orientation Templates and Free-Hand Implant Insertion in Artificial Mandibles-An Experimental Laboratory Examination in Fifth-Year Dental Students.

Authors:  Matthias C Schulz; Lena Rittmann; Ursula Range; Günter Lauer; Dominik Haim
Journal:  Dent J (Basel)       Date:  2018-09-01

7.  Computer-assisted, template-guided immediate implant placement and loading in the mandible: a case report.

Authors:  Thomas Spielau; Uli Hauschild; Joannis Katsoulis
Journal:  BMC Oral Health       Date:  2019-04-11       Impact factor: 2.757

8.  Augmented reality for dental implantology: a pilot clinical report of two cases.

Authors:  Gerardo Pellegrino; Carlo Mangano; Roberto Mangano; Agnese Ferri; Valerio Taraschi; Claudio Marchetti
Journal:  BMC Oral Health       Date:  2019-07-19       Impact factor: 2.757

9.  A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy.

Authors:  Francesco Grecchi; Luigi V Stefanelli; Fabrizio Grivetto; Emma Grecchi; Rami Siev; Ziv Mazor; Massimo Del Fabbro; Nicola Pranno; Alessio Franchina; Vittorio Di Lucia; Francesca De Angelis; Funda Goker
Journal:  Int J Environ Res Public Health       Date:  2021-06-07       Impact factor: 3.390

10.  Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft.

Authors:  Márton Kivovics; Bence Tamás Szabó; Orsolya Németh; Dóra Iványi; Bálint Trimmel; Ilona Szmirnova; Kaan Orhan; Eitan Mijiritsky; György Szabó; Csaba Dobó-Nagy
Journal:  J Clin Med       Date:  2020-01-21       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.