Literature DB >> 30123956

Histological investigation of the titanium fiber mesh with one side sealed with non-porous material for its application to the artificial heart system.

Eiji Okamoto1, Kyoko Arimura2, Yoshinori Mitamura2.   

Abstract

In this study, we investigated tissue-inducing characteristics of a titanium fiber mesh disk with one surface sealed with a non-porous material. We used sintered titanium fiber mesh (Hi-Lex Co., Zellez™, Hyogo, Japan) having a titanium fiber diameter of 50 µm and volumetric porosity of the titanium fiber mesh of 87% with an average pore size of 200 µm. The titanium fiber mesh is disk-shaped with a dimeter of 5 mm and a thickness of 1.5 mm. One side of the titanium fiber mesh disk was sealed with silicone rubber adhesive that has no venomousness and the sealed titanium fiber mesh disks were implanted in rats under the skin of the dorsal region, and they were extracted in the 4th and 12th postoperative weeks. We investigated the distribution of capillaries; also we estimated the extent of the spread of oxygen from capillaries using the diffusion equation. Microscopic observation showed that the distribution of capillaries was mainly confined to the area around the sealed titanium fiber mesh disk and that connective tissue inside the sealed titanium fiber mesh disk seemed to be in a poor condition. From estimation of the extent of the spread of oxygen from capillaries, an area in which oxygen was poorly supplied may exist in the center of the sealed titanium fiber mesh disk. In conclusion, for application of the sealed titanium fiber mesh to an artificial heart system, the thickness of the titanium fiber mesh is an important factor for keeping the inside tissue in a healthy condition.

Entities:  

Keywords:  Artificial heart; Extracellular matrix; Neoangiogenesis; Titanium mesh

Mesh:

Substances:

Year:  2018        PMID: 30123956     DOI: 10.1007/s10047-018-1066-x

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  A new titanium fiber mesh-cuffed peritoneal dialysis catheter: evaluation and comparison with a Dacron-cuffed tenckhoff catheter in goats.

Authors:  F Walboomers; Y C Paquay; J A Jansen
Journal:  Perit Dial Int       Date:  2001 May-Jun       Impact factor: 1.756

2.  Basic study of a transcutaneous information transmission system using intra-body communication.

Authors:  Eiji Okamoto; Yusuke Sato; Kazuyuki Seino; Takashi Kiyono; Yoshikuni Kato; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2010-05-08       Impact factor: 1.731

3.  Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device.

Authors:  Yukiko Yamada; Tomohiro Nishinaka; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2011-07-07       Impact factor: 1.731

4.  A one stage versus two stage surgical technique. Tissue reaction to a percutaneous device provided with titanium fiber mesh applicable for peritoneal dialysis.

Authors:  Y C Paquay; A E De Ruijter; J P van der Waerden; J A Jansen
Journal:  ASAIO J       Date:  1996 Nov-Dec       Impact factor: 2.872

5.  A new transcutaneous bidirectional communication for monitoring implanted artificial heart using the human body as a conductive medium.

Authors:  Eiji Okamoto; Yoshikuni Kato; Kazuyuki Seino; Hidekazu Miura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshinori Mitamura
Journal:  Artif Organs       Date:  2012-07-19       Impact factor: 3.094

6.  Electrical characteristic of the titanium mesh electrode for transcutaneous intrabody communication to monitor implantable artificial organs.

Authors:  Eiji Okamoto; Sakiko Kikuchi; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2016-02-26       Impact factor: 1.731

7.  [Diffusion and consumption of oxygen in the rat skin in vitro].

Authors:  H Takiwaki; R Nagai
Journal:  Nihon Hifuka Gakkai Zasshi       Date:  1986-04

8.  Diffusion coefficient of oxygen through tissues.

Authors:  J D MacDougall; M McCabe
Journal:  Nature       Date:  1967-09-09       Impact factor: 49.962

9.  Reconstruction of mandibular continuity defects with bone morphogenetic protein-2 (rhBMP-2).

Authors:  Alan S Herford; Philip J Boyne
Journal:  J Oral Maxillofac Surg       Date:  2008-04       Impact factor: 1.895

10.  Implantation with new three-dimensional porous titanium web for treatment of parietal bone defect in rabbit.

Authors:  Zhikun Guo; Shouhei Iku; Lingmin Mu; Yufeng Wang; Takaki Shima; Yasuo Seki; Qiong Li; Yoshinori Kuboki
Journal:  Artif Organs       Date:  2013-04-09       Impact factor: 3.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.