Literature DB >> 21735150

Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device.

Yukiko Yamada1, Tomohiro Nishinaka, Toshihide Mizuno, Yoshiyuki Taenaka, Eisuke Tatsumi, Kenji Yamazaki.   

Abstract

The formation of wedge thrombus is a crucial problem in any left ventricular assist device (LVAD) with a left ventricle apical inflow cannula. We therefore developed a new titanium mesh wrapped inflow cannula expecting to induce autologous neointima to avoid such wedge thrombus formation. We performed animal experiments to evaluate the feasibility of this newly developed inflow cannula with titanium mesh for the induction of autologous neointima. Four calves were implanted with the inflow cannula as well as an EVAHEART centrifugal pump LVAD (Sun Medical Technology Research Corp., Nagano, Japan) for a duration of about 2 months. The titanium mesh was enveloped with neointimal tissue grown from the ventricular endocardium. There was no thrombus formation in any of the blood pumps or around the outside of the inflow cannulas. The histological findings showed that the neointimal tissue consisted of a layer of endothelial cells and fibroblasts. The newly developed inflow cannula using a titanium mesh induces autologous neointima formation, avoiding wedge thrombus formation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21735150     DOI: 10.1007/s10047-011-0586-4

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  19 in total

1.  Clinical experience with textured blood contacting surfaces in ventricular assist devices.

Authors:  K A Dasse; S D Chipman; C N Sherman; A H Levine; O H Frazier
Journal:  ASAIO Trans       Date:  1987 Jul-Sep

2.  Biocompatibility of septal defect closure devices.

Authors:  Matthias Sigler; Christian Jux
Journal:  Heart       Date:  2006-10-11       Impact factor: 5.994

3.  Clinical results with an ePTFE inflow conduit for mechanical circulatory support.

Authors:  Tofy Mussivand; Roland Hetzer; Ettore Vitali; Bart Meyns; Philippe Noirhomme; Reiner Koerfer; Aly El-Banayosy; Ernst Wolner; Georg Wieselthaler; Bruno Reichart; Peter Uberfuhr; Robert Halfmann; Peer Portner
Journal:  J Heart Lung Transplant       Date:  2004-12       Impact factor: 10.247

4.  Do left ventricular assist device (LVAD) bridge-to-transplantation outcomes predict the results of permanent LVAD implantation?

Authors:  Jose L Navia; Patrick M McCarthy; Katherine J Hoercher; Jingyuan Feng; Rajeswaran Jeevantham; Nicholas G Smedira; Michael K Banbury; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2002-12       Impact factor: 4.330

5.  Long-term culture of human endothelial cells.

Authors:  P B Gordon; I I Sussman; V B Hatcher
Journal:  In Vitro       Date:  1983-09

6.  Immunochemical identification of human endothelial cells on the lining of a ventricular assist device.

Authors:  O H Frazier; R T Baldwin; S G Eskin; J M Duncan
Journal:  Tex Heart Inst J       Date:  1993

7.  Cerebral and systemic embolization during left ventricular support with the Novacor N100 device.

Authors:  C Schmid; M Weyand; D G Nabavi; D Hammel; M C Deng; E B Ringelstein; H H Scheld
Journal:  Ann Thorac Surg       Date:  1998-06       Impact factor: 4.330

8.  An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

Authors:  K Yamazaki; P Litwak; O Tagusari; T Mori; K Kono; M Kameneva; M Watach; L Gordon; M Miyagishima; J Tomioka; M Umezu; E Outa; J F Antaki; R L Kormos; H Koyanagi; B P Griffith
Journal:  Artif Organs       Date:  1998-06       Impact factor: 3.094

9.  Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism.

Authors:  E A Rose; H R Levin; M C Oz; O H Frazier; Q Macmanus; N A Burton; E A Lefrak
Journal:  Circulation       Date:  1994-11       Impact factor: 29.690

10.  Urgent pump exchange for stroke resulting from a distorted HeartMate XVE inflow conduit.

Authors:  O H Frazier; Matthew D Forrester; Courtney Gemmato; Igor D Gregoric
Journal:  J Heart Lung Transplant       Date:  2007-04-16       Impact factor: 10.247

View more
  4 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

2.  Histological investigation of the titanium fiber mesh with one side sealed with non-porous material for its application to the artificial heart system.

Authors:  Eiji Okamoto; Kyoko Arimura; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2018-08-20       Impact factor: 1.731

3.  Electrical characteristic of the titanium mesh electrode for transcutaneous intrabody communication to monitor implantable artificial organs.

Authors:  Eiji Okamoto; Sakiko Kikuchi; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2016-02-26       Impact factor: 1.731

4.  Effect of metal surface characteristics on the adhesion performance of the integrated low-level energies method of adhesion.

Authors:  Toshiyuki Aodai; Toru Masuzawa; Kazuhide Ozeki; Akio Kishida; Tetsuya Higami
Journal:  J Artif Organs       Date:  2012-08-30       Impact factor: 1.731

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.