We have developed a tissue-inducing electrode using titanium mesh to obtain mechanically and electrically stable contact with the tissue for a new transcutaneous communication system using the human body as a conductive medium. In this study, we investigated the electrical properties of the titanium mesh electrode by measuring electrode-tissue interface resistance in vivo. The titanium mesh electrode (Hi-Lex Co., Zellez, Hyogo, Japan) consisted of titanium fibers (diameter of 50 μm), and it has an average pore size of 200 μm and 87 % porosity. The titanium mesh electrode has a diameter of 5 mm and thickness of 1.5 mm. Three titanium mesh electrodes were implanted separately into the dorsal region of the rat. We measured the electrode-electrode impedance using an LCR meter for 12 weeks, and we calculated the tissue resistivity and electrode-tissue interface resistance. The electrode-tissue interface resistance of the titanium mesh electrode decreased slightly until the third POD and then continuously increased to 75 Ω. The electrode-tissue interface resistance of the titanium mesh electrode is stable and it has lower electrode-tissue interface resistance than that of a titanium disk electrode. The extracted titanium mesh electrode after 12 weeks implantation was fixed in 10 % buffered formalin solution and stained with hematoxylin-eosin. Light microscopic observation showed that the titanium mesh electrode was filled with connective tissue, inflammatory cells and fibroblasts with some capillaries in the pores of the titanium mesh. The results indicate that the titanium mesh electrode is a promising electrode for the new transcutaneous communication system.

Entities:  

Keywords:  Artificial heart; Electrode; Scaffold; Titanium mesh; Transcutaneous communication

Mesh:

Substances:

Year:  2016        PMID: 26920581     DOI: 10.1007/s10047-016-0889-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  Basic study of a transcutaneous information transmission system using intra-body communication.

Authors:  Eiji Okamoto; Yusuke Sato; Kazuyuki Seino; Takashi Kiyono; Yoshikuni Kato; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2010-05-08       Impact factor: 1.731

2.  Comparison of titanium-mesh and porous disc electrodes for epicardial defibrillation.

Authors:  L Rubin; D Rosenberg; V Parsonnet; A Villaneuva; M Ferrara-Ryan
Journal:  Pacing Clin Electrophysiol       Date:  1991-11       Impact factor: 1.976

3.  Evaluation of titanium mesh electrode using for transcutaneous intrabody communication by tissue-electrode impedance.

Authors:  Eiji Okamoto; Sakiko Kikuchi; Yoshinori Mitamura
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

4.  Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device.

Authors:  Yukiko Yamada; Tomohiro Nishinaka; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2011-07-07       Impact factor: 1.731

5.  A one stage versus two stage surgical technique. Tissue reaction to a percutaneous device provided with titanium fiber mesh applicable for peritoneal dialysis.

Authors:  Y C Paquay; A E De Ruijter; J P van der Waerden; J A Jansen
Journal:  ASAIO J       Date:  1996 Nov-Dec       Impact factor: 2.872

6.  Transcutaneous communication system using the human body as conductive medium: influence of transmission data current on the heart.

Authors:  Eiji Okamoto; Sakiko Kikuchi; Hidekazu Miura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshinori Mitamura
Journal:  Biomed Mater Eng       Date:  2013       Impact factor: 1.300

7.  Wound healing phenomena in titanium fibre mesh: the influence of the length of implantation.

Authors:  Y C Paquay; J E de Ruijter; J P van der Waerden; J A Jansen
Journal:  Biomaterials       Date:  1997-01       Impact factor: 12.479

8.  Bone formation by rat bone marrow cells cultured on titanium fiber mesh: effect of in vitro culture time.

Authors:  Juliette van den Dolder; Johan W M Vehof; Paul H M Spauwen; John A Jansen
Journal:  J Biomed Mater Res       Date:  2002-12-05

9.  Bone regeneration using titanium nonwoven fabrics combined with fgf-2 release from gelatin hydrogel microspheres in rabbit skull defects.

Authors:  Norihisa Ichinohe; Yoshinori Kuboki; Yasuhiko Tabata
Journal:  Tissue Eng Part A       Date:  2008-10       Impact factor: 3.845

10.  Measurement of electrode-tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium.

Authors:  Eiji Okamoto; Yoshikuni Kato; Sakiko Kikuchi; Yoshinori Mitamura
Journal:  Biomed Mater Eng       Date:  2014       Impact factor: 1.300

View more
  3 in total

Review 1.  Journal of Artificial Organs 2016: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2017-02-14       Impact factor: 1.731

2.  Histological investigation of the titanium fiber mesh with one side sealed with non-porous material for its application to the artificial heart system.

Authors:  Eiji Okamoto; Kyoko Arimura; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2018-08-20       Impact factor: 1.731

3.  Ionic Silver and Electrical Treatment for Susceptibility and Disinfection of Escherichia coli Biofilm-Contaminated Titanium Surface.

Authors:  Kritphudis Suttasattakrit; Arnon Khamkeaw; Chanchana Tangwongsan; Prasit Pavasant; Muenduen Phisalaphong
Journal:  Molecules       Date:  2021-12-28       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.