Literature DB >> 30066164

15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography.

Anders Thomassen1, Poul-Erik Braad2, Kasper T Pedersen2, Henrik Petersen2, Allan Johansen2, Axel C P Diederichsen3, Hans Mickley3, Lisette O Jensen3, Juhani Knuuti4, Oke Gerke2, Poul F Høilund-Carlsen2.   

Abstract

Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89-97%) versus 76% (64-88%), p = 0.0004; positive predictive value 71% (55-86%) versus 51% (37-65%), p = 0.0001; accuracy 90% (84-95%) versus 77% (69-84%), p = 0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.

Entities:  

Keywords:  CT angiography; Diagnostic value; Flow reserve; PET 15-O-water; Reproducibility

Mesh:

Substances:

Year:  2018        PMID: 30066164     DOI: 10.1007/s10554-018-1420-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  33 in total

1.  Enhanced diagnostic utility achieved by myocardial blood analysis: A meta-analysis of noninvasive cardiac imaging in the detection of functional coronary artery disease.

Authors:  Neng Dai; Xianlin Zhang; Yi Zhang; Lei Hou; WeiMing Li; Bing Fan; TianSong Zhang; YaWei Xu
Journal:  Int J Cardiol       Date:  2016-07-05       Impact factor: 4.164

2.  Physiological basis for angina and ST-segment change PET-verified thresholds of quantitative stress myocardial perfusion and coronary flow reserve.

Authors:  Nils P Johnson; K Lance Gould
Journal:  JACC Cardiovasc Imaging       Date:  2011-09

3.  Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve.

Authors:  Ibrahim Danad; Pieter G Raijmakers; Roel S Driessen; Jonathon Leipsic; Rekha Raju; Chris Naoum; Juhani Knuuti; Maija Mäki; Richard S Underwood; James K Min; Kimberly Elmore; Wynand J Stuijfzand; Niels van Royen; Igor I Tulevski; Aernout G Somsen; Marc C Huisman; Arthur A van Lingen; Martijn W Heymans; Peter M van de Ven; Cornelis van Kuijk; Adriaan A Lammertsma; Albert C van Rossum; Paul Knaapen
Journal:  JAMA Cardiol       Date:  2017-10-01       Impact factor: 14.676

4.  Quantitative assessment of myocardial perfusion in the detection of significant coronary artery disease: cutoff values and diagnostic accuracy of quantitative [(15)O]H2O PET imaging.

Authors:  Ibrahim Danad; Valtteri Uusitalo; Tanja Kero; Antti Saraste; Pieter G Raijmakers; Adriaan A Lammertsma; Martijn W Heymans; Sami A Kajander; Mikko Pietilä; Stefan James; Jens Sörensen; Paul Knaapen; Juhani Knuuti
Journal:  J Am Coll Cardiol       Date:  2014-10-07       Impact factor: 24.094

5.  Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease.

Authors:  Wijnand J Stuijfzand; Valtteri Uusitalo; Tanja Kero; Ibrahim Danad; Mischa T Rijnierse; Antti Saraste; Pieter G Raijmakers; Adriaan A Lammertsma; Hans J Harms; Martijn W Heymans; Marc C Huisman; Koen M Marques; Sami A Kajander; Mikko Pietilä; Jens Sörensen; Niels van Royen; Juhani Knuuti; Paul Knaapen
Journal:  Circ Cardiovasc Imaging       Date:  2015-01       Impact factor: 7.792

6.  Interobserver and interstudy variability of myocardial blood flow and flow-reserve measurements with nitrogen 13 ammonia-labeled positron emission tomography.

Authors:  S Sawada; O Muzik; R S Beanlands; E Wolfe; G D Hutchins; M Schwaiger
Journal:  J Nucl Cardiol       Date:  1995 Sep-Oct       Impact factor: 5.952

7.  Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas).

Authors:  Sergey V Nesterov; Chunlei Han; Maija Mäki; Sami Kajander; Alexandru G Naum; Hans Helenius; Irina Lisinen; Heikki Ukkonen; Mikko Pietilä; Esa Joutsiniemi; Juhani Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-04-30       Impact factor: 9.236

8.  Quantification of regional myocardial blood flow in vivo with H215O.

Authors:  S R Bergmann; K A Fox; A L Rand; K D McElvany; M J Welch; J Markham; B E Sobel
Journal:  Circulation       Date:  1984-10       Impact factor: 29.690

9.  Assessment of intra- and interobserver reproducibility of rest and cold pressor test-stimulated myocardial blood flow with (13)N-ammonia and PET.

Authors:  Thomas H Schindler; Xiao-Li Zhang; John O Prior; Jerson Cadenas; Magnus Dahlbom; James Sayre; Heinrich R Schelbert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-03       Impact factor: 10.057

10.  Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography.

Authors:  Geraint Morton; Amedeo Chiribiri; Masaki Ishida; Shazia T Hussain; Andreas Schuster; Andreas Indermuehle; Divaka Perera; Juhani Knuuti; Stacey Baker; Erik Hedström; Paul Schleyer; Michael O'Doherty; Sally Barrington; Eike Nagel
Journal:  J Am Coll Cardiol       Date:  2012-09-19       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.