Literature DB >> 6332687

Quantification of regional myocardial blood flow in vivo with H215O.

S R Bergmann, K A Fox, A L Rand, K D McElvany, M J Welch, J Markham, B E Sobel.   

Abstract

Using H215O (half-life = 2.1 min) we demonstrated that a modification of the tissue autoradiographic approach permitted quantitation of myocardial blood flow in open-chest dogs by direct assay of myocardial tissue and that noninvasive estimation with positron-emission tomography (PET) delineated relative myocardial blood flow in intact dogs. In open-chest anesthetized dogs, the single-pass extraction fraction of H215O averaged 96 +/- 5% at flows of 80 to 100 ml/100 g/min. This high extraction fraction did not differ significantly over the range of 12 to 238 ml/100 g/min. Myocardial blood flow calculated after a 60 sec intravenous infusion of H215O and direct analysis of tissue correlated well with results obtained with microspheres (r = .94, n = 9 dogs). Subsequently the approach was adapted for preliminary use with PET. Estimation of myocardial content of radiolabeled H2O after intravenous infusion of 20 to 30 mCi of H215O was corrected for vascular pool radioactivity with the use of tomographic data obtained after administration of C15O by inhalation to label red blood cells. Tomograms obtained in vivo in six dogs with either normal or reduced regional blood flow correlated closely with the tomographically detectable distribution of 68Ga-labeled microspheres (r = .93) and with postmortem microsphere distribution (r = .95). The technique accurately reflects myocardial blood flow. With the use of PET, rapid sequential noninvasive estimation of relative regional myocardial blood flow has been demonstrated that should ultimately permit improved objective assessment of nutritional blood flow in patients in response to medical and surgical interventions designed to augment perfusion.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6332687     DOI: 10.1161/01.cir.70.4.724

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  89 in total

Review 1.  Tracer kinetic modeling in nuclear cardiology.

Authors:  T R DeGrado; S R Bergmann; C K Ng; D M Raffel
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

Review 2.  An overview of radiotracers in nuclear cardiology.

Authors:  W Acampa; C Di Benedetto; A Cuocolo
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

3.  Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner.

Authors:  Hendrik J Harms; Paul Knaapen; Stefan de Haan; Rick Halbmeijer; Adriaan A Lammertsma; Mark Lubberink
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-27       Impact factor: 9.236

Review 4.  The perfusable tissue index: a marker of myocardial viability.

Authors:  Paul Knaapen; Ronald Boellaard; Marco J W Götte; Arno P van der Weerdt; Cees A Visser; Adriaan A Lammertsma; Frans C Visser
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

Review 5.  PET: Is myocardial flow quantification a clinical reality?

Authors:  Antti Saraste; Sami Kajander; Chunlei Han; Sergey V Nesterov; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

Review 6.  Quantification of myocardial blood flow and flow reserve: Technical aspects.

Authors:  Ran Klein; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

7.  Novel F-18-labeled PET myocardial perfusion tracers: bench to bedside.

Authors:  Stephan G Nekolla; Antti Saraste
Journal:  Curr Cardiol Rep       Date:  2011-04       Impact factor: 2.931

8.  Quantitative analysis of coronary endothelial function with generator-produced 82Rb PET: comparison with 15O-labelled water PET.

Authors:  Keiichiro Yoshinaga; Osamu Manabe; Chietsugu Katoh; Li Chen; Ran Klein; Masanao Naya; Robert A deKemp; Kathryn Williams; Rob S B Beanlands; Nagara Tamaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-07-13       Impact factor: 9.236

9.  Assessment of endothelial function and myocardial flow reserve using (15)O-water PET without attenuation correction.

Authors:  Stéphane Tuffier; Damien Legallois; Annette Belin; Michael Joubert; Alban Bailliez; Michel Redonnet; Denis Agostini; Alain Manrique
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-18       Impact factor: 9.236

10.  Direct comparison between 2-dimensional and 3-dimensional PET acquisition modes for myocardial blood flow absolute quantification with O-15 water and N-13 ammonia.

Authors:  Véronique Roelants; Anne Bol; Xavier Bernard; Ann Coppens; Jacques Melin; Bernhard Gerber; Jean-Louis Vanoverschelde
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

View more