Literature DB >> 17334762

Assessment of intra- and interobserver reproducibility of rest and cold pressor test-stimulated myocardial blood flow with (13)N-ammonia and PET.

Thomas H Schindler1, Xiao-Li Zhang, John O Prior, Jerson Cadenas, Magnus Dahlbom, James Sayre, Heinrich R Schelbert.   

Abstract

PURPOSE: We investigated the intraobserver reproducibility of myocardial blood flow (MBF) measurements with PET at rest and during cold pressor test (CPT), and the interobserver agreement.
METHODS: Twenty normal volunteers were studied. Using (13)N-ammonia, MBF was measured at rest and during CPT and measurement was repeated in a 1-day session (short-term reproducibility; SR). After a follow-up of 2 weeks, MBF was measured again at rest and during CPT and compared with the initial baseline measurement (long-term reproducibility; LR). In addition, adenosine-induced hyperemic MBF increases were assessed.
RESULTS: Assessment of the SR did not show a significant absolute difference in MBF at rest, MBF during CPT or the endothelium-related change in MBF from rest to CPT (DeltaMBF) (0.09 +/- 0.10, 0.11 +/- 0.09, and 0.08 +/- 0.05 ml/g/min; p = NS), and they were linearly correlated (r = 0.72, r = 0.76 and r = 0.84; p < 0.0001). Corresponding values for standard error of the estimate (SEE), as indicative for the range of MBF measurement error, were 0.14, 0.14, and 0.09 ml/g/min. The LR yielded relatively higher but non-significant absolute differences in the MBF at rest, MBF during CPT and DeltaMBF (0.10 +/- 0.10, 0.14 +/- 0.10, and 0.19 +/- 0.10 ml/g/min; p = NS), and paired MBFs significantly correlated (r = 0.75, r = 0.71, and r = 0.60; p < 0.001). Corresponding SEEs were 0.13, 0.15, and 0.16 ml/g/min. The interobserver analysis yielded a high correlation for MBF at rest, MBF during CPT, and hyperemic MBF (r = 0.96, SEE=0.04; r = 0.78, SEE=0.11; and r = 0.87, SEE=0.28; p < 0.0001, respectively), and also a good interobserver correlation for DeltaMBF (r = 0.62, SEE=0.09; p < 0.003).
CONCLUSION: Short- and long-term MBF responses to CPT, as an index for endothelium-related coronary vasomotion, can be measured reproducibly with (13)N-ammonia PET. In addition, the high interobserver reproducibility for repeat analysis of MBF values suggests the measurements to be largely operator independent.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17334762     DOI: 10.1007/s00259-007-0378-5

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   10.057


  40 in total

1.  Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose.

Authors:  S S Gambhir; M Schwaiger; S C Huang; J Krivokapich; H R Schelbert; C A Nienaber; M E Phelps
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Effects of nateglinide on myocardial microvascular reactivity in Type 2 diabetes mellitus--a randomized study using positron emission tomography.

Authors:  F M Bengel; C Abletshauser; J Neverve; O Schnell; S G Nekolla; E Standl; M Schwaiger
Journal:  Diabet Med       Date:  2005-02       Impact factor: 4.359

4.  Bicycle exercise stress in PET for assessment of coronary flow reserve: repeatability and comparison with adenosine stress.

Authors:  Christophe A Wyss; Pascal Koepfli; Krzysztof Mikolajczyk; Cyrill Burger; Gustav K von Schulthess; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

5.  Endothelial function fluctuates with diurnal variation in the frequency of ischemic episodes in patients with variant angina.

Authors:  Hiroaki Kawano; Takeshi Motoyama; Hirofumi Yasue; Nobutaka Hirai; Hesham M Waly; Kiyotaka Kugiyama; Hisao Ogawa
Journal:  J Am Coll Cardiol       Date:  2002-07-17       Impact factor: 24.094

6.  PET-measured responses of MBF to cold pressor testing correlate with indices of coronary vasomotion on quantitative coronary angiography.

Authors:  Thomas H Schindler; Egbert U Nitzsche; Manfred Olschewski; Ingo Brink; Michael Mix; John Prior; Alvaro Facta; Massayuki Inubushi; Hanjoerg Just; Heinrich R Schelbert
Journal:  J Nucl Med       Date:  2004-03       Impact factor: 10.057

7.  Relationship between increasing body weight, insulin resistance, inflammation, adipocytokine leptin, and coronary circulatory function.

Authors:  Thomas H Schindler; Jerson Cardenas; John O Prior; Alvaro D Facta; Michael C Kreissl; Xiao-Li Zhang; James Sayre; Magnus Dahlbom; Julio Licinio; Heinrich R Schelbert
Journal:  J Am Coll Cardiol       Date:  2006-02-23       Impact factor: 24.094

8.  Deferoxamine improves coronary vascular responses to sympathetic stimulation in patients with type 1 diabetes mellitus.

Authors:  Naoya Hattori; Oliver Schnell; Frank M Bengel; Julian Rihl; Stephan G Nekolla; Alexander E Drzezga; Eberhard Standl; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-24       Impact factor: 9.236

9.  Effect of short-term cardiovascular conditioning and low-fat diet on myocardial blood flow and flow reserve.

Authors:  J Czernin; R J Barnard; K T Sun; J Krivokapich; E Nitzsche; D Dorsey; M E Phelps; H R Schelbert
Journal:  Circulation       Date:  1995-07-15       Impact factor: 29.690

Review 10.  Myocardial blood flow measurement by PET: technical aspects and clinical applications.

Authors:  Philipp A Kaufmann; Paolo G Camici
Journal:  J Nucl Med       Date:  2005-01       Impact factor: 10.057

View more
  23 in total

1.  Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program.

Authors:  Ran Klein; Jennifer M Renaud; Maria C Ziadi; Stephanie L Thorn; Andy Adler; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-04-13       Impact factor: 5.952

2.  Myocardial blood flow: Putting it into clinical perspective.

Authors:  Thomas Hellmut Schindler
Journal:  J Nucl Cardiol       Date:  2015-12-28       Impact factor: 5.952

Review 3.  Role of PET in the evaluation and understanding of coronary physiology.

Authors:  Thomas H Schindler; Xiao-Li Zhang; Gabriella Vincenti; Leila Mhiri; René Lerch; Heinrich R Schelbert
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

4.  Diagnostic value of PET-measured heterogeneity in myocardial blood flows during cold pressor testing for the identification of coronary vasomotor dysfunction.

Authors:  Thomas H Schindler; Xiao-Li Zhang; Gabriella Vincenti; Leila Mhiri; Rene Nkoulou; Hanjoerg Just; Osman Ratib; Francois Mach; Magnus Dahlbom; Heinrich R Schelbert
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

5.  Effect of hormone replacement therapy on vasomotor function of the coronary microcirculation in post-menopausal women with medically treated cardiovascular risk factors.

Authors:  Thomas H Schindler; Roxana Campisi; Deborah Dorsey; John O Prior; Manfred Olschewski; James Sayre; Heinrich R Schelbert
Journal:  Eur Heart J       Date:  2009-02-26       Impact factor: 29.983

Review 6.  Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective.

Authors:  Jonathan B Moody; Benjamin C Lee; James R Corbett; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2015-04-14       Impact factor: 5.952

7.  Feasibility and operator variability of myocardial blood flow and reserve measurements with ⁹⁹mTc-sestamibi quantitative dynamic SPECT/CT imaging.

Authors:  Ran Klein; Guang-Uei Hung; Tao-Cheng Wu; Wen-Sheng Huang; Dianfu Li; Robert A deKemp; Bailing Hsu
Journal:  J Nucl Cardiol       Date:  2014-10-04       Impact factor: 5.952

8.  15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography.

Authors:  Anders Thomassen; Poul-Erik Braad; Kasper T Pedersen; Henrik Petersen; Allan Johansen; Axel C P Diederichsen; Hans Mickley; Lisette O Jensen; Juhani Knuuti; Oke Gerke; Poul F Høilund-Carlsen
Journal:  Int J Cardiovasc Imaging       Date:  2018-07-31       Impact factor: 2.357

9.  Noninvasive quantification of coronary endothelial function by SPECT imaging in children with a history of Kawasaki disease.

Authors:  Silvana Cicala; Teresa Pellegrino; Giovanni Storto; Maria Grazia Caprio; Rodolfo Paladini; Ciro Mainolfi; Francesco de Leva; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08-03       Impact factor: 9.236

10.  Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging.

Authors:  Nina Burkhard; Bernhard A Herzog; Lars Husmann; Aju P Pazhenkottil; Irene A Burger; Ronny R Buechel; Ines Valenta; Christophe A Wyss; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-23       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.