Literature DB >> 30028183

Ambient dose during intraoral radiography with current techniques: Part 1 conversion factor for scattered radiation using a rectangular collimator.

Reinier C Hoogeveen1, Tyrell I de Randamie1, Gianni M Soemodihardjo1, Wer Berkhout1.   

Abstract

OBJECTIVES: : The aim of this study was to establish a conversion factor for assessing the scattered radiation produced during intraoral radiography with a rectangular collimator in areas where the remnant beam is not present. The dose level in the remnant beam will be addressed in another study.
METHODS: : A radiological phantom (Rando) in the upright position was exposed to radiation delivered by a Planmeca Intra X-ray unit over 9 exposure geometries (right side of a full mouth series). For each geometry, the scattered radiation dose was measured at 5 locations in the horizontal plane and 4 locations in the vertical plane in front of the patient. The measurements were corrected for background and leakage radiation. An inventory of the distributions of the different geometries with respect to their share of the total workload was created in order to assign the correct weightings of the total ambient scattered radiation for the different geometries. The weightings were used to construct a scattered radiation pattern for a representative mix of exposures. The maximum value found in this pattern was used to arrive at a safe conversion factor.
RESULTS: : The scattered ambient radiation dose was evenly distributed over the horizontal plane. The scattered ambient radiation dose ranged from 20 to 65% lower in the vertical plane.
CONCLUSIONS: : The conversion factor established for scattered ambient radiation was 0.05 µSv per mAs at 1 meter. This factor is 3-fold lower than the conversion factors reported previously.

Entities:  

Mesh:

Year:  2018        PMID: 30028183      PMCID: PMC6196063          DOI: 10.1259/dmfr.20180108

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  6 in total

1.  X-ray protection in the dental office.

Authors:  A G RICHARDS; R J NELSEN; G M FTTZGERALD; S S WALD; H D SPANGENBERGER
Journal:  J Am Dent Assoc       Date:  1958-04       Impact factor: 3.634

2.  Effective dose equivalent to the operator in intra-oral dental radiography.

Authors:  R A de Haan; J van Aken
Journal:  Dentomaxillofac Radiol       Date:  1990-08       Impact factor: 2.419

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Distribution of scattered radiation during intraoral radiography with the patient in supine position.

Authors:  K Kuroyanagi; Y Hayakawa; H Fujimori; T Sugiyama
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-06

5.  Evaluation of mean conversion coefficients from air-kerma to H *(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range.

Authors:  A H Lopez Gonzales; J C Santos; L Mariano; A Tomal; P R Costa
Journal:  J Radiol Prot       Date:  2016-10-14       Impact factor: 1.394

6.  Radiation isoexposure curves about a dental chair during radiography.

Authors:  J W Rolofson; A Hamel; H F Stewart
Journal:  J Am Dent Assoc       Date:  1969-02       Impact factor: 3.634

  6 in total
  3 in total

1.  Ambient dose during intra-oral radiography with current techniques: Part 2 quantifying the remnant beam - an in vivo study.

Authors:  Reinier C Hoogeveen; Christine Ch Pfältzer; Wer Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2018-09-05       Impact factor: 2.419

2.  Ambient dose during intraoral radiography with current techniques: part 3: effect of tube voltage.

Authors:  Reinier Cornelis Hoogeveen; Dirk van Beest; Erwin Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2021-03-08       Impact factor: 2.419

3.  Diagnostic image quality of hand-held and wall-mounted X-ray devices in bitewing radiography: a non-inferiority clinical trial.

Authors:  Reinier Cornelis Hoogeveen; Siham Ouchene; Wer Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2021-01-08       Impact factor: 3.525

  3 in total