Cuff challenges in blood pressure measurement.

Paolo Palatini1, Roland Asmar2.   

Abstract

The characteristics of the optimal cuff for blood pressure (BP) measurement are still the subject of much debate. The choice of the appropriate cuff in obese individuals depends not only on the arm circumference but also on its shape because a conically shaped arm makes it difficult to fit the cuff to the arm. When a large-size cylindrical cuff is used in conical arms, an overestimation of the true BP is likely to occur with BP discrepancies that may be as large as 10 mm Hg. With the advent of automatic oscillometric devices, the choice of the appropriate cuff became even more controversial because with oscillometric BP measurement the reference point is not the artery occlusion but the oscillometric peak signal. To overcome the problem of miscuffing in obese individuals, special cuffs that can accommodate a wide range of arm sizes have been designed. Using these cuffs, accurate oscillometric BP measurements can be obtained over a wide range of arm circumferences using a unique software algorithm. These wide-range cuffs coupled to oscillometric devices may represent a good option for BP measurement in very obese subjects. However, their reliability should be confirmed in larger populations and different settings. ©2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  bladder; blood pressure; cuff; device; measurement; oscillometric

Mesh:

Year:  2018        PMID: 30003699      PMCID: PMC8030978          DOI: 10.1111/jch.13301

Source DB:  PubMed          Journal:  J Clin Hypertens (Greenwich)        ISSN: 1524-6175            Impact factor:   3.738


  18 in total

1.  Optimizing cuff width for noninvasive measurement of blood pressure.

Authors:  L A Marks; A Groch
Journal:  Blood Press Monit       Date:  2000-06       Impact factor: 1.444

2.  Cuff and bladder: overlooked components of BP measurement devices in the modern era?

Authors:  Paolo Palatini; Gerhard N Frick
Journal:  Am J Hypertens       Date:  2012-02       Impact factor: 2.689

3.  What to do when faced with an unmeasurable ambulatory blood pressure?

Authors:  Eoin O'Brien
Journal:  J Hypertens       Date:  2011-03       Impact factor: 4.844

4.  Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring.

Authors:  G S Stergiou; D Tzamouranis; E G Nasothimiou; A D Protogerou
Journal:  J Hum Hypertens       Date:  2008-07-03       Impact factor: 3.012

5.  Blood pressure measurement in very obese patients: a challenging problem.

Authors:  Paolo Palatini; Gianfranco Parati
Journal:  J Hypertens       Date:  2011-03       Impact factor: 4.844

6.  Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

Authors:  George S Stergiou; Roland Asmar; Martin Myers; Paolo Palatini; Gianfranco Parati; Andrew Shennan; Jiguang Wang; Eoin O'Brien
Journal:  J Hypertens       Date:  2018-03       Impact factor: 4.844

7.  Characterization of the oscillometric method for measuring indirect blood pressure.

Authors:  L A Geddes; M Voelz; C Combs; D Reiner; C F Babbs
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

8.  Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Circulation       Date:  2005-02-08       Impact factor: 29.690

Review 9.  Review: a century of confusion; which bladder for accurate blood pressure measurement?

Authors:  E O'Brien
Journal:  J Hum Hypertens       Date:  1996-09       Impact factor: 3.012

10.  Comparison of the conical cuff and the standard rectangular cuffs.

Authors:  G F Maxwell; J F Pruijt; A C Arntzenius
Journal:  Int J Epidemiol       Date:  1985-09       Impact factor: 7.196

View more
  9 in total

1.  History and Justification of a National Blood Pressure Measurement Validated Device Listing.

Authors:  Jordana B Cohen; Raj S Padwal; Michael Gutkin; Beverly B Green; Michael J Bloch; F Wilford Germino; Domenic A Sica; Anthony J Viera; Benjamin M Bluml; William B White; Sandra J Taler; Steven Yarows; Daichi Shimbo; Raymond R Townsend
Journal:  Hypertension       Date:  2019-02       Impact factor: 10.190

2.  Achieving reliable blood pressure measurements in clinical practice: It's time to meet the challenge.

Authors:  Eoin O'Brien; Eamon Dolan; George S Stergiou
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-07       Impact factor: 3.738

3.  Survey on arterial hypertension management: a report from the ESC Council for Cardiology Practice and the ESC Council on Hypertension.

Authors:  Costantino Mancusi; Giovanni de Simone; Riccardo Asteggiano; Dimitri Richter; Bryan Williams; Marc Ferrini
Journal:  Eur Heart J Open       Date:  2021-08-07

4.  Cuff challenges in blood pressure measurement.

Authors:  Paolo Palatini; Roland Asmar
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-07       Impact factor: 3.738

5.  The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial.

Authors:  Serpil Yüksel; Gülay Altun-Uğraş; Nurhan Altınok; Necla Demir
Journal:  Florence Nightingale J Nurs       Date:  2020-07-03

6.  Upper limb dimensions in adults presenting for elective surgery - implications for blood pressure measurement.

Authors:  Christopher Chow; Peter Ceglowski; Katie Lehane; Anita Pelecanos; Kellie Wren; Victoria A Eley
Journal:  BMC Anesthesiol       Date:  2020-04-04       Impact factor: 2.217

7.  Correlation of patient characteristics with arm and finger measurements in Asian parturients: a preliminary study.

Authors:  Ming Jian Lim; Chin Wen Tan; Hon Sen Tan; Rehena Sultana; Victoria Eley; Ban Leong Sng
Journal:  BMC Anesthesiol       Date:  2020-08-31       Impact factor: 2.217

8.  Improving Accurate Blood Pressure Cuff Allocation in Patients with Obesity: A Quality Improvement Initiative.

Authors:  Victoria Eley; Aaron Khoo; Christine Woods; Andre van Zundert
Journal:  Healthcare (Basel)       Date:  2021-03-13

9.  Assessment of nocturnal hypertension by ambulatory blood pressure monitoring at the forearm in people with morbid obesity.

Authors:  Giacomo Pucci; Marco D'Abbondanza; Matteo Camilli; Valeria Bisogni; Fabio Anastasio; Vito Gandolfo; Riccardo Alcidi; Natasa Mojovic; Stefano Ministrini; Graziana Lupattelli; Gaetano Vaudo
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-08-13       Impact factor: 3.738

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.