Literature DB >> 29988941

Utility of central venous pressure measurement in renal transplantation: Is it evidence based?

Ahmed Aref1, Tariq Zayan1, Ajay Sharma2, Ahmed Halawa2.   

Abstract

Adequate intravenous fluid therapy is essential in renal transplant recipients to ensure a good allograft perfusion. Central venous pressure (CVP) has been considered the cornerstone to guide the fluid therapy for decades; it was the only available simple tool worldwide. However, the revolutionary advances in assessing the dynamic preload variables together with the availability of new equipment to precisely measure the effect of intravenous fluids on the cardiac output had created a question mark on the future role of CVP. Despite the critical role of fluid therapy in the field of transplantation. There are only a few clinical studies that compared the CVP guided fluid therapy with the other modern techniques and their relation to the outcome in renal transplantation. Our work sheds some light on the available published data in renal transplantation, together with data from other disciplines evaluating the utility of central venous pressure measurement. Although lager well-designed studies are still required to consolidate the role of new techniques in the field of renal transplantation, we can confidently declare that the new techniques have the advantages of providing more accurate haemodynamic assessment, which results in a better patient outcome.

Entities:  

Keywords:  Central venous pressure; Fluid monitoring; Renal transplantation

Year:  2018        PMID: 29988941      PMCID: PMC6033741          DOI: 10.5500/wjt.v8.i3.61

Source DB:  PubMed          Journal:  World J Transplant        ISSN: 2220-3230


Core tip: We suggest that central venous pressure (CVP) measurement should be abandoned in renal transplantation since it may be misleading. We recommend using intra-operative and post-operative cardiac output monitoring devices for guiding fluid therapy in renal transplant recipients. Although lager well-designed studies are still required to consolidate the role of new techniques in comparison to CVP monitoring in the field of renal transplantation. We Suggest that the new methods have the advantage of providing a more accurate haemodynamic assessment in renal transplant cases.

INTRODUCTION

Central venous pressure (CVP) measurement have been in use for more than half a century to assess intravascular fluid status of renal transplant recipients and, thereby, be used as a guide for intravenous fluid therapy in renal transplantation. With the current advances in the diagnostic tools, the value of CVP is a point of debate. Several studies proved that CVP measurements are neither correlated to cardiac output nor have a precise correlation with intravascular volume status, therefore it’s value in fluid management of renal transplant recipient is at the best speculative. On the other hand, the traditionalists continue to believe that CVP values are of sufficiently good enough as a benchmark in determining resuscitation goals for a given patient. It is well recognised that optimum fluid resuscitation is essential to maximise the outcomes in critically ill patients. However, only a few studies have reliably endeavoured to assess the role of CVP in comparison to other modern techniques in the field of renal transplantation. We aim to answer this question in regards to clinical application of CVP and objectively review from the point of view of its benefits and inherent limitations.

HISTORICAL USE OF CVP

The clinical correlation between CVP and the intravascular fluid volume were established more than 50 years ago[1]. Theoretical basis of CVP is to measure the pressure in the superior vena cava (SVC) or right atrium pressure, which reflects the right ventricle preload[2]. Indeed, several textbooks have dogmatically stated that CVP provides a clinically relevant and reliable information in regards to circulatory and volume status of patients[3]. Marik et al[3] published a systematic review article that evaluated the relationship between CVP and the fluid status of the patients and concluded that CVP is an unreliable indicator of the fluid status and should not be used as a guide to fluid management. Furthermore, Marik et al[4] as per updated meta-analysis for evaluation of CVP reliability in clinical practice, reiterated abandoning the use of CVP as a guide in fluid management. Cecconi et al[5] pointed that commonly used preload measurements such as CVP or end diastolic volume, when used in isolation, cannot be used reliably as a guide to fluid resuscitation. They rather recommend using more than one hemodynamic variable for patient evaluation and management. Nonetheless, the study validated the role of CVP in certain situations as severe congestive heart failure or hypovolemia, where the use of CVP is valuable in guiding fluid management[5].

CVP IN THE CURRENT PRACTICE

CVP measurement continues to be a pedestal in day to day clinical practice. A survey studying the resuscitation practices of Canadian physicians have shown that 89.2% of them would use CVP as a monitoring parameter in septic shock as shown in Figure 1[6]. Additionally, CVP-determined endpoints were considered the end-point of volume resuscitation in the early phases of septic shock by 78.7% of the Canadian clinicians as illustrated in Figure 2[6].
Figure 1

Monitoring parameters used by intensive care unit physicians[6]. BP: Intra-arterial blood pressure; CVP: Central venous pressure; CVP oxy: Continuous monitoring of central venous oxygen saturation; Foley: Foley catheter; O2 sat: Oxygen saturation; PAC: Pulmonary artery catheter; Telem: Telemetry.

Figure 2

Volume resuscitation end-points[6]. BP: Blood pressure; CO: Cardiac output; CVP: Central venous pressure; CVP rise: Sustained rise in central venous pressure; HR: Heart rate; MvO2: Mixed venous oxygen saturation; Per Perf: Peripheral perfusion; ScvO2: Central venous oxygen saturation; UO: Urine output.

Monitoring parameters used by intensive care unit physicians[6]. BP: Intra-arterial blood pressure; CVP: Central venous pressure; CVP oxy: Continuous monitoring of central venous oxygen saturation; Foley: Foley catheter; O2 sat: Oxygen saturation; PAC: Pulmonary artery catheter; Telem: Telemetry. Volume resuscitation end-points[6]. BP: Blood pressure; CO: Cardiac output; CVP: Central venous pressure; CVP rise: Sustained rise in central venous pressure; HR: Heart rate; MvO2: Mixed venous oxygen saturation; Per Perf: Peripheral perfusion; ScvO2: Central venous oxygen saturation; UO: Urine output. Bignami et al[7] addressed the current clinical practice in hemodynamic monitoring after cardiac surgery in Italy. They analysed data collected from 71 centres using a 33-item questionnaire from. For monitoring intravascular volume status, CVP was used most frequently (26.7%), followed by arterial BP (19.7%) and echocardiography (5.6%)[7]. Sondergaard et al[8] reported that CVP, though not a direct measure of preload, can be used to assess volume status, heart performance and systemic vascular resistance.

DRAWBACKS AND LIMITATIONS OF CVP IN RELATION TO RENAL TRANSPLANTATION

Recent medical advances in understanding haemodynamic of the vascular system together with the availability of new technology have changed the scope of diagnostic approaches. We strongly feel that CVP is not the right tool in assessing the fluid balance and guide fluid therapy in renal transplantation. CVP reading is affected by several physical and anatomical factors as illustrated in Table 1[9].
Table 1

Factors affecting the measured central venous pressure reading[9]

Central venous blood volumeVenous return/cardiac output Total blood volume Regional vascular tone
Compliance of central compartmentVascular tone Right ventricular compliance: Myocardial disease Pericardial disease Tamponade
Tricuspid valve diseaseStenosis Regurgitation
Cardiac rhythmJunctional rhythm Atrial fibrillation Atrio-ventricular dissociation
Reference level of transducerPositioning of patient
Intrathoracic pressureRespiration Intermittent positive pressure ventilation Positive end-expiratory pressure Tension pneumothorax
Factors affecting the measured central venous pressure reading[9] During kidney transplant operation, the recipient is exposed to many intraoperative factors which may alter the CVP reading, hence, can be misleading in decision making. These factors can be summarised in the following points: (1) During the operation, the position of the patient is not always in flat supine position. The surgeon may be tilting the table in a different direction, commonly head down while elevating the left or the right side to improve the access to the iliac vessels. The effect of posture changes on CVP reading was documented since a long time[10]; (2) transplant surgery always entails the use of abdominal retractors. These retractors must have a pressure effect on the viscera and subsequently affect the venous return. Moreover, the tension created by the retractors will resist movement of the diaphragm and will eventually affect the intrathoracic pressure. These mechanical factors again will give a false CVP reading[11]; (3) there is positive pressure ventilation (PPV) during the transplant operation will affect the CVP reading as mentioned in Table 1[9]. There is no convincing evidence demonstrating to how much the CVP is affected by PPV; (4) the target intra-operative CVP remains elusive. While aggressive hydration ensures good allograft perfusion. On the other hand, overhydration carries the risk of pulmonary congestion, pulmonary oedema, and prolonged intubation especially in patients with pre-existing cardiac conditions[12]; (5) CKD patients on dialysis fluctuate between the volume overload state and the dry state during the post-dialysis period, which makes it difficult to declare which CVP reading should be considered as a normal reading. Additionally, the effect of ageing, long-standing hypertension and the use of various medications affecting the peripheral vascular resistance (alpha blockers, beta blockers and calcium channel blockers) would be further confounding parameters[9]; and (6) we should not forget that placement of central venous catheters and other devices may result in central vein stenosis. Central vein stenosis can jeopardise the future of arteriovenous fistula and arteriovenous graft in the ipsilateral extremity when the renal graft fails, and the patient returns to dialysis[13-15].

POSSIBLE ALTERNATIVES FOR FLUID STATUS MONITORING

The introduction of commercially available equipment for assessing dynamic preload variables [e.g., stroke volume variation (SVV)] considered a revolutionary advance in peri-operative fluid management. Srivastava et al[16] evaluated the use of intraoperative transesophageal Doppler (TED) to estimate the corrected flow time and variation in stroke volume values. TED was used to guide intraoperative fluid management in 110 living donor renal transplant recipients, and the outcome was compared with the historical records of 104 control recipients who received CVP guided fluid management over the previous year. They concluded that TED was associated with a similar rate of immediate graft function. Moreover, it was associated with a significantly less amount of intra-operative intravenous (IV) fluids, and reduced incidence of postoperative fluid overload[16]. Similarly, Kumar et al[17] studied the use of SVV (obtained from minimally invasive cardiac output monitor) to guide the perioperative fluid therapy in major abdominal surgery. The study documented a significantly lower amount of IV fluids used with the new technique, not only that but also there was a significantly shorter ICU stay, and a non-significant shorter hospital stay[17]. These non-invasive tools were used successfully as a part of enhanced recovery programs in kidney transplantation to improve patient outcomes and speed up patient’s recovery after surgery[18]. Furthermore, several other non-invasive techniques are utilised for cardiac output assessment and IV fluid guidance like lithium dilution technology (e.g., LiDCOplusTM machine) and arterial pulse wave analysis (e.g., FloTrac/VigileoTM)[19,20]. However, each one of these novel, non-invasive techniques has its own limitations. Clinicians should be aware of the underlying principles and limitations of each technique to choose the best modality for each clinical scenario individually[19,20]. Advantages and limitations of some of the currently available non-invasive approaches are summarised in Table 2[19,20].
Table 2

Advantages and limitations of some commercially available (minimally invasive) cardiac output monitoring[19,20]

ModalityExamplesAdvantagesLimitations
Pulse wave analysisLiDCOrapid™ and FloTrac/Vigileo™Requires only arterial line; Beat-by-beat CO monitoring (this may help to evaluate response to IV fluids). - Validated by clinical studies in different medical and surgical conditionsPresence of arterial line with optimum waveform signal is a prerequisite; Accuracy may be reduced by sever arrhythmia; Needs frequent recalibration during periods of hemodynamic Instability
Lithium dilutionLiDCOplusSimple technique (can use peripheral arterial line); Continuous CO monitoringArterial line required; Accuracy affected by some neuromuscular blocking drugs; Lithium chloride is contraindicated in patients undergoing treatment with lithium salts
Electrical bioimpedanceBioZ®Completely non-invasiveNumerous mathematical assumptions; Limited validity in patients with dysrhythmias
Partial CO2 rebreathingNICO™Easy to set upRequires intubation and mechanical ventilation with minimal gas exchange abnormalities and fixed ventilator settings; Accuracy decreased with haemodynamic instability
Pulsed dye densitometryDDG-330®Non-invasiveIntermittent assessment; Accuracy may be affected by vasoconstriction, movement of the sensor and interstitial oedema

CO: Cardiac output; OR: Operating room.

Advantages and limitations of some commercially available (minimally invasive) cardiac output monitoring[19,20] CO: Cardiac output; OR: Operating room. The reliability of these new techniques to guide fluid therapy in surgical cases has been investigated in several clinical trials. The conclusion of these trials is summarized in Table 3.
Table 3

Dynamic evaluation of fluid status in comparison to conventional approach

AuthorPatients No.Study groupConclusion
Berkenstadt et al[21], 200115Patients undergoing brain surgerySVV could predict fluid responsiveness to even a small volume loading of 100 mL of 6% hydroxyethyl starch given for two minutes; There was no correlation between the changes in SV and the values of the CVP and heart rate before or after loading
Rex et al[22], 200414Coronary artery bypass grafting (CABG) patientsThe dynamic index SVV allowed real-time monitoring of left ventricular preload. Moreover, it allowed assessing the haemodynamic effect of a fluid challenge; Other preload variables (i.e., PAOP, CVP, LVEDAI and ITBI) failed to predict fluid responsiveness
Preisman et al[23], 200518Coronary artery bypass grafting (CABG) patientsFunctional haemodynamic indices were superior to static indicators of cardiac preload in predicting fluid responsiveness; Use of CVP for the evaluation of intravascular volume status, have been found to lack any predictive value
Hofer et al[24], 200540CABG patientsStroke volume index was significantly correlated with SVV (P < 0.001) and PPV (P < 0.001) only; While CVP failed to have a significant correlation (P = 0.235)
Wiesenack et al[25], 200520CABG patientsStroke volume index correlated significantly with SVV and PPV derived from pulse contour analysis (P < 0.05) but not with CVP or pulmonary artery wedge pressure
Cannesson et al[26], 200618CABG patientsLeft ventricular stroke area measured by transoesophageal echocardiographic automated border detection is not only sensitive to changes in preload but also, can quantify the effects of volume expansion on cardiac output; The difference in CVP reading did not reach statistical significance in the study groups
Lee et al[27], 200720Neurosurgical patientsCorrected flow time by oesophageal Doppler and PPV are better than CVP and LVEDAI in predicting fluid responsiveness
Cannesson et al[28], 200725CABG patientsΔPOP can predict response to volume expansion as well as quantify the effects of volume expansion on hemodynamic parameters during cardiac surgery; There was no statistically significant relation between CVP and increase in cardiac index after volume expansion
Belloni et al[29], 200819CABG patientsTheir results confirm the ability of SVV (P = 0.0005) and PPV (P = 0.001) to predict fluid responsiveness in ventilated patients during cardiac surgery No significant differences were found in mean LVEDA and CVP before and after fluid administration
Biais et al[30], 200835Postoperative period of liver transplantationSVV and PPV measurement by arterial waveform analysis can be used to predict the effects of volume expansion in mechanically ventilated patients after liver transplantation; The failure of CVP and PAOP to predict fluid responsiveness agrees with increasing evidence that static preload indicators are not suitable for functional haemodynamic monitoring
Hofer et al[31], 200840CABG patientsConventional static preload parameters failed to reflect the fluid status or to predict fluid responsiveness. CVP is therefore unsuitable for predicting ventricular response to fluid loading; SVV measured by the FloTrac™/Vigileo™ and the PiCCOplus™ systems exhibited similar performances regarding predicting fluid responsiveness
de Waal et al[32], 200918CABG patientsSVV of > 8% can predict fluid responsiveness with 100% sensitivity and 78% specificity, while PPV ≥ 10% can identify fluid-responders with 64% sensitivity and 100% specificity; CVP readings were not better in predicting fluid responsiveness than random chance
Cannesson et al[33], 200925CABG patientsSVV of 10% helped in discrimination of responders to volume expansion with an 82% sensitivity and 88% specificity; SVV may be a potential alternative to DeltaPP which is an accurate predictor of fluid responsiveness in ventilated patients; SVV was significantly a better predictor of fluid responsiveness than CVP and PCWP in this study
Zimmermann et al[34], 201020Elective major abdominal surgeryBoth SVV and PVI are valid indicators of fluid responsiveness in ventilated patients during major abdominal surgery; CVP did not adequately reflect circulating blood volume and failed to predict fluid responsiveness in this study
Desgranges et al[35], 201128CABG patientsPVI can predict fluid responsiveness during general anaesthesia whatever the site of measurement in the operating room (the finger, the ear, and the forehead); PCWP and CVP showed no significant difference between responders and non-responders
Shin et al[36], 201133Elective living donor liver transplantationFemoral SVV > 8% can predict responders to fluid loading with a specificity of 80% and a sensitivity of 89%; CVP and PAOP did not correlate with the changes in the cardiac index that occurred with a fluid challenge
Broch et al[37], 201181CABG patientsSVV (P = 0.002) and PPV (P < 0.0001) were found to be reliable indicators for fluid responsiveness unlike CVP (P = 0.13) that failed to predict it; PVI ability to predict fluid responsiveness is limited in the presence of low perfusion indices
Cannesson et al[38], 2011413Multicentre study of different abdominal and cardiac surgeriesPPV [AUC 0.89 (0.86; 0.92)] is superior to CVP [AUC 0.57 (0.54; 0.59)] in prediction of fluid responsiveness (P < 0.001)
Yazigi et al[39], 201260CABG patients older than 70 yrPPV is a reliable predictor of fluid responsiveness while CVP and PAOP were not better than a random chance in predicting the response to fluid; PPV reliability was not affected by the decreased arterial compliance and increased arterial stiffness related to aging
Bogović et al[40], 201724Major (abdominal or trauma) surgeryThe study stressed on the inability of CVP to provide a valid evaluation of the preload; SVV and PPV monitored by LiDCO™ were better alternatives for preload assessment

AUC: Area under the receiver operator characteristic curve; CVP: Central venous pressure; DeltaPP: Respiratory variations in arterial pulse pressure; ITBI: Intrathoracic blood volume index; LVEDA: Left ventricular end-diastolic area; LVEDAI: Left ventricular end-diastolic area index; PAOP: Pulmonary artery occlusion pressure; PCWP: Pulmonary capillary wedge pressure; PPV: Pulse pressure variation; PVI: Pleth variability index; SV: Stroke volume; SVV: Stroke volume variation; ΔPOP: Respiratory variations in the pulse oximetry plethysmographic waveform amplitude.

Dynamic evaluation of fluid status in comparison to conventional approach AUC: Area under the receiver operator characteristic curve; CVP: Central venous pressure; DeltaPP: Respiratory variations in arterial pulse pressure; ITBI: Intrathoracic blood volume index; LVEDA: Left ventricular end-diastolic area; LVEDAI: Left ventricular end-diastolic area index; PAOP: Pulmonary artery occlusion pressure; PCWP: Pulmonary capillary wedge pressure; PPV: Pulse pressure variation; PVI: Pleth variability index; SV: Stroke volume; SVV: Stroke volume variation; ΔPOP: Respiratory variations in the pulse oximetry plethysmographic waveform amplitude.

CONCLUSION

Although CVP measurement continues to be popular, yet it is not ideal for guiding and monitoring of fluid management in renal transplantation. It is noteworthy that there may be large variations in intravascular volume status and the patients have limited range of intravascular volume that can be called euvolemia (because of co-morbidities, vascular complications, drugs and the effects of disease on the autonomic nervous system). Therefore, the volume that is infused in a patient whose fluid balance status is doubtful is going to be imprecise if CVP is to be relied upon to appreciate their baseline value. Pulmonary oedema could be the first sign of fluid overload. Other variables such as the patient position, the use of abdominal retractors, and the positive pressure ventilation make any CVP reading meaningless. As clearly evident from the data presented in Tables 1-3, we suggest that CVP measurement be abandoned in renal transplantation since it may be misleading. Alternative to CVP, we recommend using intra-operative and post-operative cardiac output monitoring devices for guiding fluid therapy in renal transplant recipients. Understanding their limitations helps to provide more robust monitoring of fluid therapy. Giving that these novel tools are only used in the ITU/HDU and operating theatre settings, management of these patients on the ward relies mainly on regular vital signs monitoring including daily body weight rather than being misled by erroneous CVP reading.
  38 in total

1.  Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.

Authors:  Maxime Cannesson; Yannick Le Manach; Christoph K Hofer; Jean Pierre Goarin; Jean-Jacques Lehot; Benoît Vallet; Benoît Tavernier
Journal:  Anesthesiology       Date:  2011-08       Impact factor: 7.892

2.  Perioperative fluid management in kidney transplantation: is volume overload still mandatory for graft function?

Authors:  A De Gasperi; S Narcisi; E Mazza; L Bettinelli; M Pavani; L Perrone; C Grugni; A Corti
Journal:  Transplant Proc       Date:  2006-04       Impact factor: 1.066

Review 3.  Central venous catheter-related thrombosis.

Authors:  William Geerts
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2014-11-18

4.  Posture and central venous pressure measurement in circulatory volume depletion.

Authors:  P Amoroso; R N Greenwood
Journal:  Lancet       Date:  1989-07-29       Impact factor: 79.321

5.  Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation.

Authors:  M Biais; K Nouette-Gaulain; V Cottenceau; P Revel; F Sztark
Journal:  Br J Anaesth       Date:  2008-10-12       Impact factor: 9.166

Review 6.  Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares.

Authors:  Paul E Marik; Michael Baram; Bobbak Vahid
Journal:  Chest       Date:  2008-07       Impact factor: 9.410

7.  Effect of intraoperative transesophageal Doppler-guided fluid therapy versus central venous pressure-guided fluid therapy on renal allograft outcome in patients undergoing living donor renal transplant surgery: a comparative study.

Authors:  Divya Srivastava; Sandeep Sahu; Abhilash Chandra; Tanmay Tiwari; Sanjay Kumar; P K Singh
Journal:  J Anesth       Date:  2015-07-28       Impact factor: 2.078

8.  Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients.

Authors:  Maxime Cannesson; Juliette Slieker; Olivier Desebbe; Fadi Farhat; Olivier Bastien; Jean-Jacques Lehot
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

9.  Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.

Authors:  Maurizio Cecconi; Daniel De Backer; Massimo Antonelli; Richard Beale; Jan Bakker; Christoph Hofer; Roman Jaeschke; Alexandre Mebazaa; Michael R Pinsky; Jean Louis Teboul; Jean Louis Vincent; Andrew Rhodes
Journal:  Intensive Care Med       Date:  2014-11-13       Impact factor: 17.440

10.  A survey of Canadian intensivists' resuscitation practices in early septic shock.

Authors:  Lauralyn A McIntyre; Paul C Hébert; Dean Fergusson; Deborah J Cook; Ashique Aziz
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

View more
  6 in total

1.  Cardiac output-guided hemodynamic therapy for adult living donor kidney transplantation in children under 20 kg: A pilot study.

Authors:  Marieke Voet; Anneliese Nusmeier; Jos Lerou; Josianne Luijten; Marlies Cornelissen; Joris Lemson
Journal:  Paediatr Anaesth       Date:  2019-08-04       Impact factor: 2.556

2.  To compare intraoperative goal directed fluid therapy by trans-oesophageal Doppler vis-à-vis FloTrac™ in patients undergoing living related renal transplantation-a prospective randomised controlled study.

Authors:  Ushkiran Kaur; Sandeep Sahu; Divya Srivastava; Tapas Kumar Singh; Prabhakar Mishra; Aneesh Srivastava
Journal:  Indian J Anaesth       Date:  2020-09-22

3.  Crystalloid fluids and delayed graft function in kidney transplant: A cohort study.

Authors:  Amr ALKouny; Mohammed K ALHarbi; Abdulrahman R ALTheaby; Ghaleb Aboalsamh; Amel Fayed
Journal:  Saudi J Anaesth       Date:  2022-01-04

4.  A randomized comparison between pulse pressure variation and central venous pressure in patients undergoing renal transplantation.

Authors:  Vipin Kumar Goyal; Priyamvada Gupta; Birbal Baj; Vishnu Kumar Garg
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2022-01-06

5.  Influence of Intraoperative Hemodynamic Parameters on Outcome in Simultaneous Pancreas-Kidney Transplant Recipients.

Authors:  Robert Sucher; Tina Schiemanck; Hans Michael Hau; Sven Laudi; Sebastian Stehr; Elisabeth Sucher; Sebastian Rademacher; Daniel Seehofer; Nora Jahn
Journal:  J Clin Med       Date:  2022-04-01       Impact factor: 4.241

6.  Anesthetic Challenges and Perioperative Factors Affecting Delayed Graft Function in Robotic-Assisted Kidney Transplant: A Review of a Single-Center Experience of 100 Cases.

Authors:  Nisha Rajmohan; Shilpa Omkarappa; Sangeeth P Srinivasan; Suresh G Nair; Rajesh Rajgopal; Nidhin Eldo
Journal:  Cureus       Date:  2022-09-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.