Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography.

Deborah Queiroz Freitas1, Taruska Ventorini Vasconcelos2, Marcel Noujeim3.   

Abstract

OBJECTIVES: To evaluate the influence of artifacts produced by zirconium implant on the diagnosis of vertical root fracture (VRF) in teeth close and distant to the implant in cone beam computed tomography (CBCT) images. We also determined if kilovoltage (kVp) and metal artifact reduction (MAR) tool could influence this diagnosis.
MATERIALS AND METHODS: Twenty single-root teeth were divided in control and fractured groups (n = 10). The teeth were randomly positioned in the first and second and right and left pre-molar alveoli of a dry human mandible. CBCT exams were acquired using a ProMax 3D unit with varying kVp (70, 80, or 90 kVp), with or without MAR, and with and without a zirconium implant placed in the alveolus of first right molar. The images were evaluated by five observers. The area under the receiver operating characteristic curve (ROC), sensitivity, and specificity were calculated and compared by analysis of variance with a significance level of 5%.
RESULTS: In general, ROC and sensitivity were not affected by the factors studied (p > 0.05). The main effects occurred in specificity; when implant was used without MAR, the values were lower for tooth 45 for all kVps (p = 0.0001).
CONCLUSIONS: Artifacts produced in the vicinity of teeth with suspected VRF impair the diagnosis by decreasing the specificity, because they can mimic the VRF line generating false positives. However, MAR improves the specificity, being its use recommended when metallic objects are present near teeth with suspected VRF. CLINICAL RELEVANCE: Since nowadays, many patients who undergo CBCT show implants and they definitively produce artifacts, it is important to evaluate the influence of such artifacts in the diagnosis of teeth that are close to the generator-artifact object.

Entities:  

Keywords:  Artifact; Artifact reduction tool; Cone beam computed tomography; Kilovoltage; Vertical root fracture

Year:  2018        PMID: 29984377     DOI: 10.1007/s00784-018-2558-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  7 in total

1.  Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?

Authors:  Eduarda Helena Leandro Nascimento; Hugo Gaêta-Araujo; Rocharles Cavalcante Fontenele; Nicolly Oliveira-Santos; Christiano Oliveira-Santos; Deborah Queiroz Freitas
Journal:  Clin Oral Investig       Date:  2021-02-24       Impact factor: 3.573

2.  Assessment of fractures in endodontically treated teeth restored with and without root canal posts using high-resolution cone beam computed tomography.

Authors:  David Aristizabal-Elejalde; Luis-Ernesto Arriola-Guillén; Aron Aliaga-Del Castillo; Gustavo-Armando Ruíz-Mora; Yalil-Augusto Rodríguez-Cárdenas
Journal:  J Clin Exp Dent       Date:  2020-06-01

3.  Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images.

Authors:  Letícia Queiroz Mauad; Paulo Victor Teixeira Doriguêtto; Daniela de Almeida; Karolina Aparecida Castilho Fardim; Alessiana Helena Machado; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

4.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

5.  Influence of windowing and metal artefact reduction algorithms on the volumetric dimensions of five different high-density materials: a cone-beam CT study.

Authors:  Fernanda Coelho-Silva; Luciano Augusto Cano Martins; Daniela Azeredo Braga; Eliana Zandonade; Francisco Haiter-Neto; Sergio Lins de-Azevedo-Vaz
Journal:  Dentomaxillofac Radiol       Date:  2020-06-25       Impact factor: 2.419

6.  Does the metal artifact reduction algorithm activation mode influence the magnitude of artifacts in CBCT images?

Authors:  Rocharles C Fontenele; Eduarda H L Nascimento; Gustavo M Santaella; Deborah Q Freitas
Journal:  Imaging Sci Dent       Date:  2020-03-17

7.  Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Arthur Xavier Maseti Mancini; Deborah Queiroz Freitas; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-03-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.