Literature DB >> 32665813

Assessment of fractures in endodontically treated teeth restored with and without root canal posts using high-resolution cone beam computed tomography.

David Aristizabal-Elejalde1, Luis-Ernesto Arriola-Guillén2, Aron Aliaga-Del Castillo3, Gustavo-Armando Ruíz-Mora4, Yalil-Augusto Rodríguez-Cárdenas5.   

Abstract

BACKGROUND: Root fractures are a diagnostic challenge for dentists in endodontic treatment. This study aimed to determine the relationship between the characteristics of tooth fractures and the presence of root canal posts in endodontically treated teeth using high-resolution cone beam computed tomography (CBCT).
MATERIAL AND METHODS: Fifty high-resolution CBCT scans of endodontically treated teeth with a diagnosis of fracture were obtained, of which 30 were from women and 20 were from men. These scans were acquired with three Veraviewepocs 3D units and one 3D Accuitomo 170 unit, with a 40 × 40-mm field of view and 125 μm voxel size. The variables assessed included the type of fracture, extent of fracture, type of retention, post length, cause of endodontic failure, location of the lesion, and time required to detect the fracture (difficulty score). For data analysis, the chi-squared test, Student's t-test, and multiple linear regression (α <0.05) were used.
RESULTS: No association was found between the type of fracture and type of retention or between the type of fracture and its extent (P>0.05). On the other hand, the type of fracture significantly influenced the time required for its detection. Additionally, the most difficult plane for detecting the fracture and the difficulty score were associated, with statistically significant results.
CONCLUSIONS: The type of fracture in endodontically treated teeth was not associated with the type of post used for restoration. All of the CBCT systems used to detect tooth fracture showed the same efficiency. Key words:Cone-Beam CT, Tooth Fracture, Root Canal Post. Copyright:
© 2020 Medicina Oral S.L.

Entities:  

Year:  2020        PMID: 32665813      PMCID: PMC7335599          DOI: 10.4317/jced.56854

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  32 in total

Review 1.  Detection accuracy of root fractures in cone-beam computed tomography images: a systematic review and meta-analysis.

Authors:  R H Ma; Z P Ge; G Li
Journal:  Int Endod J       Date:  2015-07-17       Impact factor: 5.264

Review 2.  Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

Authors:  Rubens Spin-Neto; Erik Gotfredsen; Ann Wenzel
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

3.  Radiographic detection of artificially created horizontal root fracture using different cone beam CT units with small fields of view.

Authors:  K Kamburoglu; B Onder; S Murat; H Avsever; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

4.  Evaluation of root canal configuration of maxillary molars in a Brazilian population using cone-beam computed tomographic imaging: an in vivo study.

Authors:  Emmanuel João Nogueira Leal Silva; Yuri Nejaim; Amaro I V Silva; Francisco Haiter-Neto; Alexandre A Zaia; Nestor Cohenca
Journal:  J Endod       Date:  2013-11-09       Impact factor: 4.171

5.  Vertical root fractures of endodontically treated posterior teeth: A histologic analysis with clinical and radiographic correlates.

Authors:  Thomas von Arx; Dieter Bosshardt
Journal:  Swiss Dent J       Date:  2017-01-12

6.  Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography.

Authors:  Deborah Queiroz Freitas; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Clin Oral Investig       Date:  2018-07-08       Impact factor: 3.573

Review 7.  Radiographic diagnosis of root fractures: a systematic review, meta-analyses and sources of heterogeneity.

Authors:  Fernanda Cristina Sales Salineiro; Solange Kobayashi-Velasco; Mariana Minatel Braga; Marcelo Gusmão Paraiso Cavalcanti
Journal:  Dentomaxillofac Radiol       Date:  2017-11-02       Impact factor: 2.419

8.  Horizontal root fractures in posterior teeth without dental trauma: tooth/root distribution and clinical characteristics.

Authors:  Y-L Tsai; W-C Liao; C-Y Wang; M-C Chang; S-H Chang; S-F Chang; C-W Chang; Y-D Huang; C-P Chan; J-H Jeng
Journal:  Int Endod J       Date:  2016-11-05       Impact factor: 5.264

9.  Diagnostic value of cone-beam computed tomography and periapical radiography in detection of vertical root fracture.

Authors:  Fatemeh Ezzodini Ardakani; Seyed Hossein Razavi; Mehdi Tabrizizadeh
Journal:  Iran Endod J       Date:  2015-03-18

10.  Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

Authors:  Abbas Shokri; Amir Eskandarloo; Marouf Norouzi; Jalal Poorolajal; Gelareh Majidi; Alireza Aliyaly
Journal:  Imaging Sci Dent       Date:  2018-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.