| Literature DB >> 29940905 |
Zhi Cui1, Zhao Wei2, Minquan Du3, Ping Yan4, Han Jiang5.
Abstract
BACKGROUND: Comparison of the shaping ability of advanced nickel-titanium (Ni-Ti) instruments is of great interest to the field of endodontics. However, the models used to study canal preparation still lack uniformity, relevance to reality and complexity. The aim of this study was thus to compare the shaping abilities of the ProTaper Next (PN) and WaveOne (WO) Ni-Ti instruments in three-dimensional (3D)-printed teeth, which may overcome the present defects of most real teeth and model teeth including 3D S-shaped canals.Entities:
Keywords: Micro-computed tomography imaging; Printed resin teeth; ProTaper next; Three-dimensional S-shaped root canal; WaveOne
Mesh:
Substances:
Year: 2018 PMID: 29940905 PMCID: PMC6019729 DOI: 10.1186/s12903-018-0573-8
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Images of a real premolar and its 3D-printed replica. a Image of the chosen premolar, b image of the 3D-printed tooth, c and d micro-CT images of (a) and (b), respectively
Volumes and surface areas of real and 3D-printed canals pre- and post-preparation (n = 12)
| Group | Volume before preparation (mm3) | Volume after preparation (mm3) | Surface area before preparation (mm2) | Surface area after preparation (mm2) |
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | |
| Real teeth | 2.82 ± .74 | 2.94 ± .75 | 19.61 ± 3.65 | 20.51 ± 3.58 |
| 3D-printed teeth | 2.78 ± .73 | 2.97 ± .77 | 19.57 ± 3.60 | 20.59 ± 3.24 |
| .289b | .064a | .387b | .494a |
aPaired-samples T test (P < .05)
bWilcoxon signed-rank test (P < .05)
Transportation in four sections of real and printed canals after preparation (n = 12)
| Group | 1 mm from apex (mm) | 3 mm from apex (mm) | 5 mm from apex (mm) | 9 mm from apex (mm) |
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | |
| Real teeth | .047 ± .037 | .053 ± .042 | .052 ± .052 | .013 ± .014 |
| 3D-printed teeth | .053 ± .042 | .06 ± .053 | .056 ± .056 | .014 ± .016 |
| .084b | .058b | .655b |
bWilcoxon signed-rank test (P < .05)
Fig. 2Images comparing the original premolar to a 3D-printed replica tooth. (a) (b) (c) Images of the root canal of a premolar, showing the pre-preparation canals in blue and the post-preparation areas in red. (c) The untouched areas are presented after overlapping (a) and (b). Pre-preparation, post-preparation and overlapping root canal images for the 3D-printed tooth are shown in yellow (d), green (e), and (f), respectively. (g) and (h) show overlapping canal images for the real premolar and the 3D-printed tooth before and after preparation, respectively
Fig. 3The different directions of the overlapping images of the S-shaped root canals. The coronal curvatures of the pre- and post-preparation canals are shown in green and red, respectively. The pre- and post-preparation apical regions are shown in blue and yellow, respectively. Column a shows images of the prepared root canals, and images of the post-preparation canals are shown in column b. In column c, the untouched areas are presented after overlapping the images in the a and b columns. Finally, column d shows the sections of the overlapping canals
Volumes and surface areas of post-preparation simulated canals (n = 10)
| Instrument | Volume (mm3) | Surface area (mm2) | ||
|---|---|---|---|---|
| Mean ± SD | Min-Max | Mean ± SD | Min-Max | |
| ProTaper Next | 3.21 ± .04 | 3.16–3.27 | 21.22 ± .77 | 20.24–22.70 |
| WaveOne | 3.37 ± .06 | 3.24–3.46 | 22.67 ± .61 | 21.89–23.63 |
| <.001d | <.001c | |||
cIndependent-samples T test (P < .05)
dMann-Whitney U test (P < .05)
Percentages of unprepared areas in the apical and coronal halves of canals (n = 10)
| Instrument | Unprepared apical area (%) | Unprepared coronal area (%) | ||
|---|---|---|---|---|
| Mean ± SD | Min-Max | Mean ± SD | Min-Max | |
| ProTaper Next | 11.03 ± .96 | 10.11–12.8 | 55.70 ± 1.25 | 53.26–57.19 |
| WaveOne | 12.06 ± 1.21 | 9.25–13.10 | 55.53 ± 1.01 | 53.48–57.24 |
| .683c | .684c | |||
cIndependent-samples T test (P < .05)
Transportation at the apical and coronal curvatures (n = 10)
| Instrument | Apical curvature (mm) | Coronal curvature (mm) | ||
|---|---|---|---|---|
| Mean ± SD | Min-Max | Mean ± SD | Min-Max | |
| ProTaper Next | 0.14 ± .03 0.19 | 0.09–0.20 | 0.41 ± .04 0.43 | 0.37–0.50 |
| WaveOne | ±.05 | 0.11–0.27 | ±.06 | 0.35–0.50 |
| .014c | .404c | |||
cIndependent-samples T test (P < .05)