Literature DB >> 22625863

Changes in centring and shaping ability using three nickel–titanium instrumentation techniques analysed by micro-computed tomography (μCT).

S Stern1, S Patel, F Foschi, M Sherriff, F Mannocci.   

Abstract

AIM: To compare the centring ability and the shaping ability of ProTaper (PT) files used in reciprocating motion and PT and Twisted Files (TF) used in continuous rotary motion, and to compare the volume changes obtained with the different instrumentation techniques using micro-computed tomography. Methodology Sixty mesial canals of thirty mandibular molars were randomly assigned to three instrumentation techniques: group 1, canals prepared with the PT series (up to F2) (n = 20); group 2, canals prepared with the F2 PT in reciprocating motion (n = 20); group 3 canals prepared with the TF series (size 25) (n = 20). Teeth were scanned pre- and postoperatively using micro-computed tomography to measure volume and shaping changes, and the obtained results were statistically analysed using parametric tests. Results The increase in canal volume obtained with the three instrumentation techniques was not significantly different. Canals were transported mostly towards the mesial aspect in the apical- and mid-third of the roots, and towards the furcal aspect coronally. No difference in the transportation and centring ratio was found between the techniques. There was no significant difference between the times of instrumentation (TF: 62.5 ± 5.4 s; PT: 60.6 ± 3.9 s; and F2 PT file in reciprocating motion: 51.0 ± 3.3 s). Conclusions ProTaper files used in reciprocating motion and PT and TF used in continuous rotary motion were capable of producing centred preparations with no substantial procedural errors.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22625863     DOI: 10.1111/j.1365-2591.2011.02004.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  23 in total

1.  Shaping ability of two nickel-titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study.

Authors:  E Pedullà; G Plotino; N M Grande; G Avarotti; G Gambarini; E Rapisarda; F Mannocci
Journal:  Clin Oral Investig       Date:  2016-02-15       Impact factor: 3.573

2.  Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT.

Authors:  Anil Dhingra; Nayasha Manchanda
Journal:  J Clin Diagn Res       Date:  2014-11-20

3.  Comparison of retreatment ability of full-sequence reciprocating instrumentation and 360° rotary instrumentation.

Authors:  Ismail Davut Capar; Tuba Gok; Ezgi Orhan
Journal:  Clin Oral Investig       Date:  2015-03-29       Impact factor: 3.573

4.  Comparative analysis of canal transportation and centring ability of three Ni-Ti rotary endodontic systems: Protaper®, MTwo® and Revo-S™, assessed by micro-computed tomography.

Authors:  Karen Vallaeys; Valérie Chevalier; Reza Arbab-Chirani
Journal:  Odontology       Date:  2014-09-24       Impact factor: 2.634

5.  Shaping Ability of Reciproc, UnicOne, and Protaper Universal in Simulated Root Canals.

Authors:  Etevaldo Matos Maia Filho; Cláudia de Castro Rizzi; Matheus Bandeca Coelho; Sara Freitas Santos; Luzia Mayanne Oliveira Costa; Ceci Nunes Carvalho; Rudys Rodolfo de Jesus Tavarez; Janir Alves Soares
Journal:  ScientificWorldJournal       Date:  2015-04-09

6.  Root canal centering ability of rotary cutting nickel titanium instruments: A meta-analysis.

Authors:  Mohan Gundappa; Rashmi Bansal; Sarvesh Khoriya; Ranjana Mohan
Journal:  J Conserv Dent       Date:  2014-11

7.  Root canal shaping by single-file systems and rotary instruments: a laboratory study.

Authors:  Khaly Bane; Babacar Faye; Mouhamed Sarr; Seydina O Niang; Diouma Ndiaye; Pierre Machtou
Journal:  Iran Endod J       Date:  2015-03-18

8.  A comparative evaluation of root canal area increase using three different nickel-titanium rotary systems: An ex vivo cone-beam computed tomographic analysis.

Authors:  Adrija Deka; A C Bhuyan; Darpana Bhuyan
Journal:  Contemp Clin Dent       Date:  2015 Jan-Mar

9.  Shaping Ability of Single-file Systems with Different Movements: A Micro-computed Tomographic Study.

Authors:  Joedy Santa-Rosa; Manoel Damião de Sousa-Neto; Marco Aurelio Versiani; Giselle Nevares; Felipe Xavier; Kaline Romeiro; Marcely Cassimiro; Graziela Bianchi Leoni; Rebeca Ferraz de Menezes; Diana Albuquerque
Journal:  Iran Endod J       Date:  2016-05-01

10.  Shaping ability of reciproc and TF adaptive systems in severely curved canals of rapid microCT-based prototyping molar replicas.

Authors:  Ronald Ordinola-Zapata; Clovis Monteiro Bramante; Marco Antonio Húngaro Duarte; Bruno Cavalini Cavenago; David Jaramillo; Marco Aurélio Versiani
Journal:  J Appl Oral Sci       Date:  2014-06-10       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.