Literature DB >> 15606817

Comparison of root canal preparation using RaCe and ProTaper rotary Ni-Ti instruments.

F Paqué1, U Musch, M Hülsmann.   

Abstract

AIM: To compare various parameters of root canal preparation using RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (Ni-Ti) instruments.
METHODOLOGY: Fifty extracted mandibular molars with mesial root canal curvatures between 20 degrees and 40 degrees were embedded in a muffle system. All root canals were prepared to size 30 using RaCe or ProTaper rotary instruments in low-torque motors with torque control and constant speed of 300 r.p.m. (ProTaper with ATR Tecnika, Advanced Technology Research, Pistoia, Italy; RaCe with EndoStepper, S.E.T., Olching, Germany). In both groups irrigation was performed with 2 mL NaOCl (3%) after each instrument size. Calcinase-Slide (lege artis, Dettenhausen, Germany) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal cross-sections, safety issues and working time. Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. Statistical analysis was performed using the following tests: Wilcoxon's test for straightening and working time was used (P < 0.05); Fisher's exact test for comparison of cross-sections and root canal cleanliness (P < 0.05).
RESULTS: Both Ni-Ti systems maintained curvature well; the mean degree of straightening was less than 1 degrees for both systems. Following preparation with RaCe, 49% of the root canals had a round or oval diameter and 50% an irregular diameter, ProTaper preparations resulted in a round or oval diameter in 50% of the cases. For debris, RaCe and ProTaper achieved 47 and 49% scores of 1 and 2, respectively; there was no significant difference. For smear layer, RaCe and ProTaper achieved 51 and 33% scores 1 and 2, respectively; no statistically significant differences were apparent for the coronal and middle sections of the root canals, but RaCe performed significantly better in the apical region (Fisher's exact test, P = 0.0392). Two roots lost working length with RaCe instruments, whilst ProTaper preparation resulted in two roots loosing working length and one fractured instrument. Mean working time was shorter for ProTaper (90.9 s) than for RaCe (137.6 s); the difference was significant (Wilcoxon's test, P = 0.011).
CONCLUSIONS: Both systems respected original root canal curvature well and were safe to use. Cleanliness was not satisfactory for both systems.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15606817     DOI: 10.1111/j.1365-2591.2004.00889.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  45 in total

1.  A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals.

Authors:  Young-Sil Yoo; Yong-Bum Cho
Journal:  Restor Dent Endod       Date:  2012-11-21

2.  A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals.

Authors:  Gaurav Sharma; Pooja Kakkar; Asit Vats
Journal:  J Clin Diagn Res       Date:  2015-03-01

3.  Apical leakage of epiphany root canal sealer combined with different master cones.

Authors:  Mustafa Murat Kocak; Ozgur Er; Baran Can Saglam; Sis Yaman
Journal:  Eur J Dent       Date:  2008-04

4.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

5.  An ex vivo comparative analysis on shaping ability of four NiTi rotary endodontic instruments using spiral computed tomography.

Authors:  Nitin Maitin; D Arunagiri; Dexter Brave; Shipra Nangalia Maitin; Sandeep Kaushik; Saumya Roy
Journal:  J Conserv Dent       Date:  2013-05

6.  Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

Authors:  Maira de Souza Carvalho; Emílio Carlos Sponchiado; Angela Delfina Bitencourt Garrido; Lucas da Fonseca Roberti Garcia; André Augusto Franco Marques
Journal:  Eur J Dent       Date:  2015 Jan-Mar

7.  Microscopic evaluation of cleaning efficiency of three different nickel-titanium rotary instruments.

Authors:  Maryam Bidar; Saeed Moradi; Maryam Forghani; Salma Bidad; Mahtab Azghadi; Shahrzad Rezvani; Shirin Khoynezhad
Journal:  Iran Endod J       Date:  2010-11-15

8.  A Survey on NiTi Rotary Instruments Usage by Endodontists and General Dentist in Tehran.

Authors:  Mohammad Ali Mozayeni; Amin Golshah; Nafiseh Nik Kerdar
Journal:  Iran Endod J       Date:  2011-11-15

9.  Shaping ability of nickel-titanium rotary instruments in curved root canals.

Authors:  Ali Talati; Saeed Moradi; Maryam Forghani; Ali Monajemzadeh
Journal:  Iran Endod J       Date:  2013-05-01

10.  Effectiveness of a new canal brushing technique in removing calcium hydroxide from the root canal system: A scanning electron microscope study.

Authors:  Melahat Gorduysus; Zeliha Yilmaz; Omer Gorduysus; Burcu Atila; Senem Oransal Karapinar
Journal:  J Conserv Dent       Date:  2012-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.