Literature DB >> 12752650

A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments.

M Hülsmann1, G Gressmann, F Schäfers.   

Abstract

AIM: To compare several parameters of root canal preparation using two different rotary nickel-titanium (Ni-Ti) instruments: FlexMaster (VDW, Munich, Germany) and HERO 642 (Micro-Mega, Besançon, France).
METHODOLOGY: Fifty extracted human mandibular molars with root canal curvatures between 20 and 40 degrees were embedded into a muffle system. All root canals were prepared to size 45 using a high-torque motor with two different Ni-Ti instruments, FlexMaster and HERO 642. In both groups, irrigation was performed with 2 mL NaOCl (3%) after each instrument size. RC-Prep (Premier, Philadelphia, USA) was used as a chelating agent with each instrument. The following parameters were evaluated: straightening of curved root canals, postoperative root canal diameter, working safety (file fractures, perforations, apical blockages, loss of working length), cleaning ability and working time. Statistical analysis was performed using the Wilcoxon's test (P < 0.05) for straightening and Fishers's exact test (P < 0.05) for comparison of cross-sections, contact between pre- and postoperative diameter, root canal cleanliness and working time.
RESULTS: Both Ni-Ti systems maintained the curvature well: the mean degree of straightening was 0.6 degrees for FlexMaster and 0.5 degrees for HERO 642. One file was fractured with the FlexMaster system, but further procedural incidents were not recorded. Following preparation with FlexMaster, 18% of the root canals had a round diameter, 53% an oval diameter and 29% an irregular diameter; HERO 642 preparations resulted in a round diameter in 25%, oval shape in 47% and irregular cross-sections in 28% of the cases. Mean working time was shorter for HERO 642 (66.0 s) than for FlexMaster (71.1 s). Cleanliness of the root canal walls was investigated under the SEM using 5-score indices for debris and smear layer. For debris, HERO 642 and FlexMaster achieved 73 and 70% scores of 1 and 2, respectively. The results for smear layer were similar: HERO 642 and FlexMaster achieved 33 and 26% scores of 1 and 2, respectively. Significant differences between the two systems were not detected for any of the parameters evaluated.
CONCLUSIONS: Both systems respected original root canal curvature well and were safe. Both systems failed to remove debris and smear layer in the majority of the cases.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12752650     DOI: 10.1046/j.1365-2591.2003.00664.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  24 in total

1.  Appearance of the root canal walls after preparation with NiTi rotary instruments: a comparative SEM investigation.

Authors:  Carlo Prati; Federico Foschi; Cesare Nucci; Lucio Montebugnoli; Silvia Marchionni
Journal:  Clin Oral Investig       Date:  2004-02-04       Impact factor: 3.573

2.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

3.  A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography - An ex vivo study.

Authors:  Gopal S Narayan; Sokkalingam Mothilal Venkatesan; C S Karumaran; Rajamani Indira; S Ramachandran; M R Srinivasan
Journal:  Contemp Clin Dent       Date:  2012-09

4.  A scanning electron microscope study on the effect of an experimental irrigation solution on smear layer removal.

Authors:  Vahid Zand; Hadi Mokhtari; Mehrdad Lotfi; Saeed Rahimi; Aydin Sohrabi; Sina Badamchi Zadeh; Hanieh Mojaver Kahnamooie; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2014-03-08

5.  Comparing the Fracture Rate of Hero 642, FlexMaster and Mtwo in the Simulated Canals.

Authors:  Hosein Labaf; Roza Haghgoo; Kiumars Nazarimoghadam; Mahshid Mohamadibasir
Journal:  Iran Endod J       Date:  2014-03-08

6.  Microscopic evaluation of cleaning efficiency of three different nickel-titanium rotary instruments.

Authors:  Maryam Bidar; Saeed Moradi; Maryam Forghani; Salma Bidad; Mahtab Azghadi; Shahrzad Rezvani; Shirin Khoynezhad
Journal:  Iran Endod J       Date:  2010-11-15

7.  A Survey on NiTi Rotary Instruments Usage by Endodontists and General Dentist in Tehran.

Authors:  Mohammad Ali Mozayeni; Amin Golshah; Nafiseh Nik Kerdar
Journal:  Iran Endod J       Date:  2011-11-15

Review 8.  Rotary endodontics in primary teeth - A review.

Authors:  Sageena George; S Anandaraj; Jyoti S Issac; Sheen A John; Anoop Harris
Journal:  Saudi Dent J       Date:  2015-11-22

9.  Comparative evaluation of the sealing ability of different obturation systems used over apically separated rotary nickel-titanium files: An in vitro study.

Authors:  Krishnakumar Gollahalli Rangappa; Jayshree Hegde; Champa Chikkamallaiah; Kusum Bashetty; Krishna Rashmi; Krishna K Kumar
Journal:  J Conserv Dent       Date:  2013-09

10.  Comparison of extracted teeth and simulated resin blocks on apical canal transportation.

Authors:  Zohreh Khalilak; Arjang Fallahdoost; Bahareh Dadresanfar; Gholamreza Rezvani
Journal:  Iran Endod J       Date:  2008-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.