Literature DB >> 29932791

Implant orientation accuracy of a hand-held robotic partial knee replacement system over conventional technique in a cadaveric test.

Rahul Khare1, Branislav Jaramaz1, Brian Hamlin2, Kenneth L Urish3,4,5.   

Abstract

Unicondylar Knee Arthroplasty (UKA) is a minimally-invasive surgical procedure for treating isolated compartmental knee osteoarthritis. Accurate implant placement is crucial for a successful UKA procedure. Previous work has shown the improvement in UKA by using robotic systems. Here, we present the implant alignment accuracy of a hand-held robotic UKA system compared with a conventional manual UKA system for 12 cadaver specimens. Two surgeons carried out equal number of medial UKAs with robotic UKA on one knee and the manual UKA on the other knee. Preoperative and postoperative computed tomography (CT) scans were obtained for each cadaveric model. The final implant positions were identified in the postoperative CT scan. The implant orientations were compared with the planned implant positions to obtain femoral and tibial implant alignment errors. Our results show that the femoral flexion, varus, and rotation root mean square errors for the robotic and conventional approach were 1.23°, 2.81°, 1.62° and 7.52°, 6.25°, 5.0°, respectively. The tibial slope and varus errors for the robotic and conventional approaches were 2.41°, 2.96° and 4.06°, 1.8°, respectively. We did not find any statistical significant difference (p = .05) in the performance of the two surgeons. We conclude that the hand-held robotic UKA system offers significant improvement in the final implant placement.

Entities:  

Keywords:  cadaver study; implant accuracy; partial knee replacement; unicondylar knee arthroplasty

Mesh:

Year:  2018        PMID: 29932791      PMCID: PMC6309277          DOI: 10.1080/24699322.2018.1484167

Source DB:  PubMed          Journal:  Comput Assist Surg (Abingdon)        ISSN: 2469-9322            Impact factor:   1.787


  19 in total

1.  Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty.

Authors:  Nicholas J Dunbar; Martin W Roche; Brian H Park; Sharon H Branch; Michael A Conditt; Scott A Banks
Journal:  J Arthroplasty       Date:  2011-11-15       Impact factor: 4.757

2.  Early failure of unicompartmental knee arthroplasty leading to revision.

Authors:  Thomas J Aleto; Michael E Berend; Merrill A Ritter; Philip M Faris; R Michael Meneghini
Journal:  J Arthroplasty       Date:  2008-02       Impact factor: 4.757

Review 3.  Unicompartmental knee arthroplasty.

Authors:  Todd Borus; Thomas Thornhill
Journal:  J Am Acad Orthop Surg       Date:  2008-01       Impact factor: 3.020

4.  A five to seven-year follow-up of unicondylar arthroplasty.

Authors:  J Insall; P Aglietti
Journal:  J Bone Joint Surg Am       Date:  1980-12       Impact factor: 5.284

5.  Minimally invasive implantation and computer navigation for a unicondylar knee system.

Authors:  Klaus Buckup; Lars-Christoph Linke; Volker Hahne
Journal:  Orthopedics       Date:  2007-08       Impact factor: 1.390

6.  Unicompartmental tibiofemoral resurfacing arthroplasty.

Authors:  R S Laskin
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

7.  Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up.

Authors:  Luigi Molfetta; Davide Caldo
Journal:  Knee       Date:  2008-01-30       Impact factor: 2.199

8.  Robotic clinical trials of uni-condylar arthroplasty.

Authors:  F Rodriguez; S Harris; M Jakopec; A Barrett; P Gomes; J Henckel; J Cobb; B Davies
Journal:  Int J Med Robot       Date:  2005-12       Impact factor: 2.547

9.  Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty.

Authors:  Matthew B Collier; C Anderson Engh; James P McAuley; Gerard A Engh
Journal:  J Bone Joint Surg Am       Date:  2007-06       Impact factor: 5.284

10.  Unicompartmental knee arthroplasty enables near normal gait at higher speeds, unlike total knee arthroplasty.

Authors:  Anatole V Wiik; Victoria Manning; Robin K Strachan; Andrew A Amis; Justin Peter Cobb
Journal:  J Arthroplasty       Date:  2013-10       Impact factor: 4.757

View more
  1 in total

1.  Current role of handheld navigation system in total knee arthroplasty: where we are?

Authors:  Jong-Heon Kim; Woo-Sung Kim; Hyun-Soo Ok; Seong Hwan Kim
Journal:  Ann Transl Med       Date:  2020-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.