Literature DB >> 18234498

Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up.

Luigi Molfetta1, Davide Caldo.   

Abstract

BACKGROUND: There is no evidence in the current literature of any significant improvement in clinical outcome when comparing computer-assisted total knee arthroplasty (CATKA) with conventional implantation. Analyses of alignment and of component orientation have shown both significant and non-significant differences between the two methods.
OBJECTIVES: We compared computer-assisted and conventional surgery for TKA at 5.4 years follow-up for patients with varus osteoarthritic knees. Our goal was to assess clinical outcome and restoration of normal limb alignment.
MATERIALS AND METHODS: We performed a retrospective case-control study comparing 30 patients who underwent CATKA with 30 subjects who underwent TKA by conventional methods. Patients were matched individually by preoperative clinical conditions and alignment. We analysed intraoperative data (surgical time and intraoperative complications), postoperative complications, lower limb alignment, radiographic complication on X-ray imaging, and clinical outcome through knee and function score and range of motion. RESULTS AND DISCUSSION: We found no significant clinical difference between the two groups at 5 years post-surgery. However there was a statistically significant improvement in the restoration of the mechanical axis of the lower limb in the coronal plane but not in the sagittal plane. Whether or not this leads to a higher survival rate in the longer term requires further investigation.

Entities:  

Mesh:

Year:  2008        PMID: 18234498     DOI: 10.1016/j.knee.2007.12.006

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  29 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

3.  No difference in ROM and knee function between mobile and floating platforms in TKA.

Authors:  Johannes Holinka; Navid Bahrami; Richard Lass; Sophie Frantal; Reinhard Windhager; Hugo Axel Wanivenhaus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-29       Impact factor: 4.342

4.  Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study.

Authors:  Jörg Lützner; Klaus-Peter Günther; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-05       Impact factor: 4.342

5.  Three-dimensional analysis of image-free navigation system for total knee arthroplasty.

Authors:  D Tigani; E Rimondi; P Trentani; M Ansaloni; L Amendola; D Testi
Journal:  Musculoskelet Surg       Date:  2010-12-29

6.  A randomized controlled clinical and radiological trial about outcomes of navigation-assisted TKA compared to conventional TKA: long-term follow-up.

Authors:  E K Song; Pranav R Agrawal; S K Kim; H Y Seo; J K Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-01       Impact factor: 4.342

7.  Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

Authors:  Mark Yaffe; Michael Luo; Nitin Goyal; Philip Chan; Anay Patel; Max Cayo; S David Stulberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

8.  [Cost analysis for navigation in knee endoprosthetics].

Authors:  O Cerha; S Kirschner; K-P Günther; J Lützner
Journal:  Orthopade       Date:  2009-12       Impact factor: 1.087

Review 9.  Clinical outcome and quality of life after computer-assisted total knee arthroplasty: results from a prospective, single-surgeon study and review of the literature.

Authors:  Christian-Dominik Peterlein; Markus Dietmar Schofer; Susanne Fuchs-Winkelmann; Friedrich Georg Scherf
Journal:  Chir Organi Mov       Date:  2009-10-30

10.  A five to seven year follow-up comparing computer-assisted vs freehand TKR with regard to clinical parameters.

Authors:  C Lüring; M Kauper; H Bäthis; L Perlick; J Beckmann; J Grifka; M Tingart; B Rath
Journal:  Int Orthop       Date:  2011-06-15       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.