Literature DB >> 29876628

Comparison between free-hand and O-arm-based navigated posterior lumbar interbody fusion in elderly cohorts with three-level lumbar degenerative disease.

Yucheng Wang1, Kangwu Chen1, Hao Chen1, Kai Zhang1, Jian Lu1, Haiqing Mao2, Huilin Yang3.   

Abstract

PURPOSE: This retrospective cohort study aims to evaluate the effects of introducing the O-arm-based navigation technique into the traditional posterior lumbar interbody fusion (PLIF) procedure treating elderly patients with three-level lumbar degenerative diseases.
METHODS: Forty-one consecutive elderly patients were enrolled according to the criteria. There were 21 patients in the free-hand group and 20 patients in the O-arm group. Both two groups underwent the PLIF with or without the O-arm-based navigation technique. The demographic features, clinical data and outcomes, and radiological information were collected for further analysis.
RESULTS: The average follow-up time was 18.3 (range, 12-28) months in the free-hand group and 16.7 (range, 12-24) months in the O-arm group. Comparison between two groups revealed no significant difference regarding demographic features. The operation time took in the navigation group was significantly less than that in the free-hand group (222.55 ± 38.00 mins versus 255.19 ± 40.26 mins, P < 0.05). Both VAS and ODI were improved post-operatively in two groups while comparison between groups showed no difference. The accuracy rate of pedicle screw positioning was 88.7% in the free-hand group to 96.9% in the O-arm group (P < 0.05).
CONCLUSION: The O-arm-based navigation is an efficacious auxiliary technique which could significantly improve the accuracy of pedicle screw insertion, especially in cases of patients with complex anatomic degenerative diseases, without sacrificing the feasibility and reliable outcome of traditional PLIF.

Entities:  

Keywords:  Elderly patients; Lumbar degenerative disease; O-arm-based navigation; Posterior lumbar interbody fusion; Three-level

Mesh:

Year:  2018        PMID: 29876628     DOI: 10.1007/s00264-018-4005-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients.

Authors:  T Laine; T Lund; M Ylikoski; J Lohikoski; D Schlenzka
Journal:  Eur Spine J       Date:  2000-06       Impact factor: 3.134

2.  The treatment of ruptured lumbar intervertebral discs by vertebral body fusion. I. Indications, operative technique, after care.

Authors:  R B CLOWARD
Journal:  J Neurosurg       Date:  1953-03       Impact factor: 5.115

3.  Radiation exposure to the surgeon during percutaneous pedicle screw placement.

Authors:  Thomas E Mroz; Kalil G Abdullah; Michael P Steinmetz; Eric O Klineberg; Isador H Lieberman
Journal:  J Spinal Disord Tech       Date:  2011-06

4.  A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws.

Authors:  Gregory P Lekovic; Eric A Potts; Dean G Karahalios; Graham Hall
Journal:  J Neurosurg Spine       Date:  2007-10

Review 5.  Image guidance in spine surgery.

Authors:  Langston T Holly; Kevin T Foley
Journal:  Orthop Clin North Am       Date:  2007-07       Impact factor: 2.472

Review 6.  Posterior lumbar interbody fusion.

Authors:  Christian P DiPaola; Robert W Molinari
Journal:  J Am Acad Orthop Surg       Date:  2008-03       Impact factor: 3.020

7.  Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques.

Authors:  J Silbermann; F Riese; Y Allam; T Reichert; H Koeppert; M Gutberlet
Journal:  Eur Spine J       Date:  2011-01-21       Impact factor: 3.134

8.  Accuracy of pedicular screw placement in vivo.

Authors:  S D Gertzbein; S E Robbins
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

Review 9.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

Review 10.  Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis.

Authors:  Yongjung J Kim; Lawrence G Lenke; Samuel K Cho; Keith H Bridwell; Brenda Sides; Kathy Blanke
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-15       Impact factor: 3.468

View more
  6 in total

1.  Safety and efficacy of percutaneous kyphoplasty assisted with O-arm navigation for the treatment of osteoporotic vertebral compression fractures at T6 to T9 vertebrae.

Authors:  Yijian Zhang; Hao Liu; Fan He; Angela Chen; Huilin Yang; Bin Pi
Journal:  Int Orthop       Date:  2019-12-18       Impact factor: 3.075

2.  Prospective Evaluation of the Time Required for Insertion of 380 Lumbar and Sacral Pedicle Screws Using Navigation with an Intraoperative 3-Dimensional Imaging System.

Authors:  Benjamin Tze Keong Ding; Arun-Kumar Kaliya-Perumal; Jacob Yoong-Leong Oh; Chun-Sing Yu
Journal:  Int J Spine Surg       Date:  2020-06-30

3.  Bone conductivity and spine fluoroscopy, Hand-Eye-Ear dialogue, during pedicle screw positioning: a new human cognitive system for precision and radiation-decrease; better than artificial intelligence and machine learning system?

Authors:  Harkirat Bhogal; Sagi Martinov; Pauline Buteau; Olivier Bath; Jacques Hernigou
Journal:  Int Orthop       Date:  2022-08-05       Impact factor: 3.479

4.  Unilateral biportal endoscopic lumbar interbody fusion assisted by intraoperative O-arm total navigation for lumbar degenerative disease: A retrospective study.

Authors:  Xinle Huang; Junfeng Gong; Huan Liu; Zegang Shi; Wenkai Wang; Shuai Chen; Xiaobing Shi; Changqing Li; Yu Tang; Yue Zhou
Journal:  Front Surg       Date:  2022-09-23

5.  Comparison of O-arm navigation and microscope-assisted minimally invasive transforaminal lumbar interbody fusion and conventional transforaminal lumbar interbody fusion for the treatment of lumbar isthmic spondylolisthesis.

Authors:  Peng Peng; Kangwu Chen; Hao Chen; Kai Zhang; Jiajia Sun; Peng Yang; Feng Zhou; Yu Liu; Huilin Yang; Haiqing Mao
Journal:  J Orthop Translat       Date:  2019-10-31       Impact factor: 5.191

6.  Percutaneous short-segment pedicle instrumentation assisted with O-arm navigation in the treatment of thoracolumbar burst fractures.

Authors:  Peng Yang; Kangwu Chen; Kai Zhang; Jiajia Sun; Huilin Yang; Haiqing Mao
Journal:  J Orthop Translat       Date:  2019-12-05       Impact factor: 5.191

  6 in total