Literature DB >> 29797347

WITHDRAWN: Resorbable versus titanium plates for facial fractures.

Mojtaba Dorri1, Richard Oliver.   

Abstract

BACKGROUND: Rigid internal fixation of the jaw bones is a routine procedure for the management of facial fractures. Titanium plates and screws are routinely used for this purpose. The limitations of this system has led to the development of plates manufactured from bioresorbable materials which, in some cases, omits the necessity for the second surgery. However, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions.
OBJECTIVES: To compare the effectiveness of bioresorbable fixation systems with titanium systems for the management of facial fractures. SEARCH
METHODS: We searched the following databases: The Cochrane Oral Health Group's Trials Register (to 20th August 2008), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2008, Issue 3), MEDLINE (1950 to 20th August 2008), EMBASE (from 1980 to 20th August 2008), http://www.clinicaltrials.gov/ and http://www.controlled-trials.com (to 20th August 2008). SELECTION CRITERIA: Randomised controlled trials comparing resorbable versus titanium fixation systems used for facial fractures. DATA COLLECTION AND ANALYSIS: Retrieved studies were independently screened by two review authors. Results were to be expressed as random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. MAIN
RESULTS: The search strategy retrieved 53 potentially eligible studies. None of the retrieved studies met our inclusion criteria and all were excluded from this review. One study is awaiting classification as we failed to obtain the full text copy. Three ongoing trials were retrieved, two of which were stopped before recruiting the planned number of participants. In one study, the excess complications in the resorbable arm was declared as the reason for stopping the trial. AUTHORS'
CONCLUSIONS: This review illustrates that there are no published randomised controlled clinical trials relevant to this review question. There is currently insufficient evidence for the effectiveness of resorbable fixation systems compared with conventional titanium systems for facial fractures. The findings of this review, based on the results of the aborted trials, do not suggest that resorbable plates are as effective as titanium plates. In future, the results of ongoing clinical trials may provide high level reliable evidence for assisting clinicians and patients for decision making. Trialists should design their studies accurately and comprehensively to meet the aims and objectives defined for the study.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29797347      PMCID: PMC6494524          DOI: 10.1002/14651858.CD007158.pub3

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  14 in total

1.  Resorbable implants (plates and screws) in orthognathic surgery.

Authors:  I K Mohamed-Hashem; D A Mitchell
Journal:  J Orthod       Date:  2000-06

2.  Bone biological plate for stabilization of maxillary inferior repositioning.

Authors:  F Costa; M Robiony; N Zerman; E Zorzan; M Politi
Journal:  Minerva Stomatol       Date:  2005-04

3.  [Bioresorbable screws in comparison with titanium screws for osteosynthesis after sagittal fracture of the mandible--a prospective, randomized, controlled clinical study].

Authors:  H Böhm; H Pistner; T Barth; J Reuther; J Mühling
Journal:  Biomed Tech (Berl)       Date:  1998       Impact factor: 1.411

4.  Bias in meta-analysis detected by a simple, graphical test.

Authors:  M Egger; G Davey Smith; M Schneider; C Minder
Journal:  BMJ       Date:  1997-09-13

5.  Evaluation of Bioresorbable vis-à-vis Titanium Plates and Screws for Craniofacial Fractures and Osteotomies.

Authors:  S Menon; Skr Chowdhury
Journal:  Med J Armed Forces India       Date:  2011-07-21

Review 6.  A comparison of combinations of titanium and resorbable plating systems for repair of isolated zygomatic fractures in the adult: a quantitative biomechanical study.

Authors:  Michael Hanemann; Oliver Simmons; Sonu Jain; Richard Baratta; Aldo Benjamin Guerra; Stephen Eric Metzinger
Journal:  Ann Plast Surg       Date:  2005-04       Impact factor: 1.539

7.  Epidemiology of maxillofacial injuries at trauma hospitals in Ontario, Canada, between 1992 and 1997.

Authors:  N J Hogg; T C Stewart; J E Armstrong; M J Girotti
Journal:  J Trauma       Date:  2000-09

8.  Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis?

Authors:  Gert Wittwer; Wasiu Lanre Adeyemo; Kaan Yerit; Martin Voracek; Dritan Turhani; Franz Watzinger; Georg Enislidis
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-01-19

9.  Biodegradable polylactide plates and screws in orthognathic surgery: technical note.

Authors:  P E Haers; R Suuronen; C Lindqvist; H Sailer
Journal:  J Craniomaxillofac Surg       Date:  1998-04       Impact factor: 2.078

Review 10.  Resorbable versus titanium plates for orthognathic surgery.

Authors:  Z Fedorowicz; M Nasser; J T Newton; R J Oliver
Journal:  Cochrane Database Syst Rev       Date:  2007-04-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.