A comparison of combinations of titanium and resorbable plating systems for repair of isolated zygomatic fractures in the adult: a quantitative biomechanical study.

Michael Hanemann1, Oliver Simmons, Sonu Jain, Richard Baratta, Aldo Benjamin Guerra, Stephen Eric Metzinger.   

Abstract

Multiple studies have sought to determine the postreduction stability of internal fixation in zygomaticomaxillary complex (ZMC) fractures. Three-point fixation with titanium miniplates is increasingly recommended to repair these injuries. Use of bioresorbable plates has been suggested to eliminate potential postoperative hardware complications. By quantitatively comparing different combinations of titanium and resorbable plating systems, this study attempts to demonstrate which combinations will provide stable fixation of the fractured ZMC. Osteotomies were performed on 40 zygomas in 20 fresh-frozen cadaver skulls, simulating noncomminuted ZMC fractures. The control group (group 0) consisted of titanium plates at the zygomaticofrontal (ZF) suture, infraorbital rim (IOR), and zygomaticomaxillary buttress (ZMB). Group 1 consisted of titanium plates at the ZF and IOR, and a resorbable plate at the ZMB. Group 2 used a titanium plate at the ZF, and resorbable plates at the IOR and ZMB. Group 3 consisted of resorbable plates at the ZF, IOR, and ZMB. A mechanical test system was used to apply loads in the vectorial direction of the masseter. Critical forces and patterns of hardware failure were recorded. Group 0 failed at a mean force of 589 +/- 146 N (60 kg). Group 1 failed at a mean force of 507 +/- 124 N (52 kg). No statistically significant differences between groups 0 and 1 were found. The mean force required for failure in groups 2 and 3 was lower. Differences in the force required for failure between groups 2 and 3 and the control group was significant (P <0.05). Failure patterns were analyzed. The ZF plate tended to stretch predominantly in groups 1, 2, and 3, whereas it tended to break in group 0 (P = 0.005). The IOR plate demonstrated predictable screw failure in groups 2 and 3 (P = 0.007). For group 0, the ZF was the site of the majority of critical failures. For groups 2 and 3, the IOR was almost invariably the site of critical failure (P = 0.004). At the ZMB, there was no significant association between failure modes and it was rarely the site of critical failure, regardless of the method of fixation. However, the strength of fixation was proportional to the number of titanium plates used. Overall, the method of fixation significantly affected the force required for mechanical failure of ZMC fractures (P <0.0001). The presence of teeth significantly increases the force required for implant failure in ZMC fracture fixation when combinations of plates are used (P = 0.038). All combinations of titanium and resorbable plates may be sufficient to overcome the displacing forces produced by the masseter and may be used for internal fixation of isolated ZMC fractures in the adult.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15785282     DOI: 10.1097/01.sap.0000151484.59846.62

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  7 in total

Review 1.  [Is routine implant removal after trauma surgery sensible?].

Authors:  C Krettek; C Müller; R Meller; M Jagodzinski; F Hildebrand; R Gaulke
Journal:  Unfallchirurg       Date:  2012-04       Impact factor: 1.000

2.  Current Management of Zygomaticomaxillary Complex Fractures: A Multidisciplinary Survey and Literature Review.

Authors:  Scott J Farber; Dennis C Nguyen; Gary B Skolnick; Albert S Woo; Kamlesh B Patel
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-09-16

Review 3.  WITHDRAWN: Resorbable versus titanium plates for facial fractures.

Authors:  Mojtaba Dorri; Richard Oliver
Journal:  Cochrane Database Syst Rev       Date:  2018-05-23

4.  Wire or Hook Traction for Reducing Zygomatic Fracture.

Authors:  Hee Chang Ahn; Dong Hyun Youn; Matthew Seung Suk Choi; Jung-Woo Chang; Jang Hyun Lee
Journal:  Arch Craniofac Surg       Date:  2015-12-09

5.  Advantages of intraoral and transconjunctival approaches for posterior displacement of a fractured zygomaticomaxillary complex.

Authors:  Ji Yong Yoo; Jang Won Lee; Seung Jae Paek; Won Jong Park; Eun Joo Choi; Kyung-Hwan Kwon; Moon-Gi Choi
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-10-25

6.  Zygomatic complex fracture: A comparative evaluation of stability using titanium and bio-resorbable plates as one point fixation.

Authors:  Nalini Tripathi; Manoj Goyal; Brijesh Mishra; Satish Dhasmana
Journal:  Natl J Maxillofac Surg       Date:  2013-07

Review 7.  Resorbable versus titanium plates for orthognathic surgery.

Authors:  Anirudha Agnihotry; Zbys Fedorowicz; Mona Nasser; Karanjot S Gill
Journal:  Cochrane Database Syst Rev       Date:  2017-10-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.