Literature DB >> 15973236

Bone biological plate for stabilization of maxillary inferior repositioning.

F Costa1, M Robiony, N Zerman, E Zorzan, M Politi.   

Abstract

AIM: Inferior repositioning of the maxilla to correct vertical maxillary deficiency has been one of the more unstable orthognathic procedures performed. Different surgical techniques have been proposed to stabilize downward movement of the maxilla. The aim of this study was to evaluate the skeletal stability of maxillary anterior downgrafting using bone biological plates in association to bone plates and bone graft for skeletal stabilization.
METHODS: The records of 6 patients were evaluated cephalometrically, analyzing the presurgical, immediate postsurgical and long-term follow-up radiographs. All patients had one-piece Le Fort I osteotomy with anterior downgraft of at least 2 mm at point A. Any horizontal movement of the maxilla concomitant with the downgraft was no more than 5 mm. Rigid fixation with titanium miniplates and screws and with bone biological plate was used to stabilize the maxilla. In the sample of 6 patients, 3 underwent one-jaw (maxilla only) surgery and 3 two-jaw surgery.
RESULTS: The mean surgical inferior downgrafting at point A was 5+/-1.4 mm (P<0.001) with a relapse of 0.16+/-1. 63 mm (3.2% of surgical movement). The mean surgical inferior downgrafting at the anterior nasal spine (ANS) was 5.66+/-1.36 mm (P<0.001) with a relapse of 0.41+/-1.56 mm (7.32% of surgical movement). Relapse in the vertical dimension failed to reach any statistical significance for all maxillary landmarks.
CONCLUSIONS: Anterior downgrafting of the maxilla with this fixation method seems to be a stable and predictable procedure. The use of bone biological plates seems to substantially improve skeletal stability even if further investigations with a more consistent sample of patients is required.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15973236

Source DB:  PubMed          Journal:  Minerva Stomatol        ISSN: 0026-4970


  4 in total

1.  Diagnosing and treatment planning inadequate tooth display.

Authors:  F Spear
Journal:  Br Dent J       Date:  2016-10-21       Impact factor: 1.626

2.  Mandible and Zygomatic Fracture in a 2-Year-Old Patient due to Dog Bite.

Authors:  Jesús R Manzani Baldi; Daniel A Wolff de Freitas
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-03-05

Review 3.  WITHDRAWN: Resorbable versus titanium plates for facial fractures.

Authors:  Mojtaba Dorri; Richard Oliver
Journal:  Cochrane Database Syst Rev       Date:  2018-05-23

Review 4.  Resorbable versus titanium plates for orthognathic surgery.

Authors:  Anirudha Agnihotry; Zbys Fedorowicz; Mona Nasser; Karanjot S Gill
Journal:  Cochrane Database Syst Rev       Date:  2017-10-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.