Literature DB >> 17443617

Resorbable versus titanium plates for orthognathic surgery.

Z Fedorowicz1, M Nasser, J T Newton, R J Oliver.   

Abstract

BACKGROUND: Recognition of some of the limitations of titanium plates and screws used for the fixation of bones has led to the development of plates manufactured from bioresorbable materials. Whilst resorbable plates appear to offer clinical advantages over metal plates in orthognathic surgery, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions.
OBJECTIVES: To compare the effectiveness of bioresorbable fixation systems with titanium systems used during orthognathic surgery. SEARCH STRATEGY: We searched the following databases: Cochrane Oral Health Group Trials Register (to 26th January 2006); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 4); MEDLINE (without filter) (from 1966 to 26th January 2006); and EMBASE (without filter) (from 1980 to 26th January 2006). SELECTION CRITERIA: Randomised controlled trials comparing resorbable versus titanium fixation systems used for orthognathic surgery. DATA COLLECTION AND ANALYSIS: Clinical heterogeneity between the included trials precluded pooling of data, and only a descriptive summary is presented. MAIN
RESULTS: This review included two trials, involving 103 participants, one compared titanium with resorbable plates and screws and the other titanium with resorbable screws, both provided very limited data for the primary outcomes of this review. All patients in one trial suffered mild to moderate postoperative discomfort with no statistically significant difference between the two plating groups at different follow-up times. Mean scores of patient satisfaction were 7.43 to 8.63 (range 0 to 10) with no statistically significant difference between the two groups throughout follow up. Adverse effects reported in one study were two plate exposures in each group occurring between the third and ninth months. Plate exposures occurred mainly in the posterior maxillary region, except for one titanium plate exposure in the mandibular premolar region. Known causes of infection were associated with loosened screws and wound dehiscence with no statistically significant difference in the infection rate between titanium (3/196), and resorbable (3/165) plates P = 0.83 (published as P = 0.67). AUTHORS'
CONCLUSIONS: This review provides some evidence to show that there is no statistically significant difference in postoperative discomfort, level of patient satisfaction, plate exposure or infection for plate and screw fixation using either titanium or resorbable materials in orthognathic surgery.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17443617     DOI: 10.1002/14651858.CD006204.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  10 in total

1.  [Implant materials for the internal fixation of midfacial fractures].

Authors:  B A Stuck; T Heller
Journal:  HNO       Date:  2011-11       Impact factor: 1.284

Review 2.  Orthognathic correction of dento-facial discrepancies.

Authors:  S J Cunningham; A Johal
Journal:  Br Dent J       Date:  2015-02-16       Impact factor: 1.626

3.  Mandible and Zygomatic Fracture in a 2-Year-Old Patient due to Dog Bite.

Authors:  Jesús R Manzani Baldi; Daniel A Wolff de Freitas
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-03-05

4.  Injectable biomaterials for regenerating complex craniofacial tissues.

Authors:  James D Kretlow; Simon Young; Leda Klouda; Mark Wong; Antonios G Mikos
Journal:  Adv Mater       Date:  2009-09-04       Impact factor: 30.849

Review 5.  WITHDRAWN: Resorbable versus titanium plates for facial fractures.

Authors:  Mojtaba Dorri; Richard Oliver
Journal:  Cochrane Database Syst Rev       Date:  2018-05-23

6.  Grading the quality of evidence and strength of recommendations: the GRADE approach to improving dental clinical guidelines.

Authors:  Mona Nasser; Zbys Fedorowicz
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

Review 7.  Overview of innovative advances in bioresorbable plate systems for oral and maxillofacial surgery.

Authors:  Takahiro Kanno; Shintaro Sukegawa; Yoshihiko Furuki; Yoshiki Nariai; Joji Sekine
Journal:  Jpn Dent Sci Rev       Date:  2018-04-05

Review 8.  Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Authors:  Barzi Gareb; Nico B Van Bakelen; Arjan Vissink; Ruud R M Bos; Baucke Van Minnen
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

Review 9.  Resorbable versus titanium plates for orthognathic surgery.

Authors:  Anirudha Agnihotry; Zbys Fedorowicz; Mona Nasser; Karanjot S Gill
Journal:  Cochrane Database Syst Rev       Date:  2017-10-04

Review 10.  Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis.

Authors:  Barzi Gareb; Nico B van Bakelen; Pieter U Dijkstra; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Eur J Oral Sci       Date:  2021-06-15       Impact factor: 2.612

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.