Literature DB >> 29721516

Model-based beamforming with plane wave synthesis in medical ultrasound.

Kazuyuki Dei1, Jaime Tierney1, Brett Byram1.   

Abstract

We are interested in examining how our model-based beamforming algorithm, referred to as aperture-domain model image reconstruction (ADMIRE), performs on plane wave sequences in conjunction with synthetic aperture beamforming. We also aim to identify the impact of ADMIRE applied before and after synthetic focusing. We employed simulated phantoms using Field II and tissue-mimicking phantoms to evaluate ADMIRE as applied to synthetic sequencing. We generated plane wave images with and without synthetic aperture focusing (SAF) and measured contrast and contrast-to-noise ratio (CNR). For simulated cyst images formed from single plane waves, the contrast for delay-and-sum (DAS) and ADMIRE are 15.64 and 28.34 dB, respectively, whereas the CNR are 1.76 and 3.90 dB, respectively. We also applied ADMIRE to simulated resolution phantoms having a point target at 3 cm depth on-axis. We simulated the point spread functions from data obtained from 1 plane wave and 75 steered plane waves, along with linear scans with 3 and 4 cm- focal depths. We then compared the outcome of applying ADMIRE before and after SAF using 3 and 11 steered plane waves. Finally, we applied this to an in vivo carotid artery. Based on the findings in this study, ADMIRE can be adapted to full field insonification sequences to improve image quality in plane wave imaging. Additionally, we investigated how robustly ADMIRE performs in the presence of random noise. We then address identified limitations using a conventional envelope detection method with decluttered signals.

Entities:  

Keywords:  beamforming; clutter suppression; envelope detection; medical ultrasound; model; plane wave imaging; random noise; speckle statistics; synthetic aperture focusing

Year:  2018        PMID: 29721516      PMCID: PMC5918768          DOI: 10.1117/1.JMI.5.2.027001

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  14 in total

1.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

2.  Improvement of tissue harmonic imaging using the pulse-inversion technique.

Authors:  Qingyu Ma; Yong Ma; Xiufen Gong; Dong Zhang
Journal:  Ultrasound Med Biol       Date:  2005-07       Impact factor: 2.998

3.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

4.  Broadband minimum variance beamforming for ultrasound imaging.

Authors:  Iben Kraglund Holfort; Fredrik Gran; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-02       Impact factor: 2.725

5.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Authors:  Gabriel Montaldo; Mickaël Tanter; Jérémy Bercoff; Nicolas Benech; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

6.  High frame-rate blood vector velocity imaging using plane waves: simulations and preliminary experiments.

Authors:  Jesper Udesen; Fredrik Gran; Kristoffer Lindskov Hansen; Jørgen Arendt Jensen; Carsten Thomsen; Michael Bachmann Nielsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-08       Impact factor: 2.725

7.  Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications: a simulation study.

Authors:  Ling Tong; Hang Gao; Hon Fai Choi; Jan D'hooge
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-08       Impact factor: 2.725

8.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

Review 9.  Ultrafast cardiac ultrasound imaging: technical principles, applications, and clinical benefits.

Authors:  Maja Cikes; Ling Tong; George R Sutherland; Jan D'hooge
Journal:  JACC Cardiovasc Imaging       Date:  2014-08

10.  Regularization Paths for Generalized Linear Models via Coordinate Descent.

Authors:  Jerome Friedman; Trevor Hastie; Rob Tibshirani
Journal:  J Stat Softw       Date:  2010       Impact factor: 6.440

View more
  2 in total

1.  Computationally Efficient Implementation of Aperture Domain Model Image Reconstruction.

Authors:  Kazuyuki Dei; Siegfried Schlunk; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-26       Impact factor: 2.725

2.  Feasibility of non-linear beamforming ultrasound methods to characterize and size kidney stones.

Authors:  Ryan S Hsi; Siegfried G Schlunk; Jaime E Tierney; Kazuyuki Dei; Rebecca Jones; Mark George; Pranav Karve; Ravindra Duddu; Brett C Byram
Journal:  PLoS One       Date:  2018-08-28       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.