Broadband minimum variance beamforming for ultrasound imaging.

Iben Kraglund Holfort1, Fredrik Gran, Jørgen Arendt Jensen.   

Abstract

A minimum variance (MV) approach for near-field beamforming of broadband data is proposed. The approach is implemented in the frequency domain, and it provides a set of adapted, complex apodization weights for each frequency subband. The performance of the proposed MV beamformer is tested on simulated data obtained using Field II. The method is validated using synthetic aperture data and data obtained from a plane wave emission. Data for 13 point targets and a circular cyst with a radius of 5 mm are simulated. The performance of the MV beamformer is compared with delay-and-sum (DS) using boxcar weights and Hanning weights and is quantified by the full width at half maximum (FWHM) and the peak-side-lobe level (PSL). Single emission {DS boxcar, DS Hanning, MV} provide a PSL of {-16, -36, -49} dB and a FWHM of {0.79, 1.33, 0.08} mm. Using all 128 emissions, {DS boxcar, DS Hanning, MV} provides a PSL of {-32, -49, -65} dB, and a FWHM of {0.63, 0.97, 0.08} mm. The contrast of the beamformed single emission responses of the circular cyst was calculated as {-18, -37, -40} dB. The simulations have shown that the frequency subband MV beamformer provides a significant increase in lateral resolution compared with DS, even when using considerably fewer emissions. An increase in resolution is seen when using only one single emission. Furthermore, the effect of steering vector errors is investigated. The steering vector errors are investigated by applying an error of the sound speed estimate to the ultrasound data. As the error increases, it is seen that the MV beamformer is not as robust compared with the DS beamformer with boxcar and Hanning weights. Nevertheless, it is noted that the DS does not outperform the MV beamformer. For errors of 2% and 4% of the correct value, the FWHM are {0.81, 1.25, 0.34} mm and {0.89, 1.44, 0.46} mm, respectively.

Entities:  

Mesh:

Year:  2009        PMID: 19251518     DOI: 10.1109/TUFFC.2009.1040

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  38 in total

1.  Weighted Capon beamformer combined with coded excitation in ultrasound imaging.

Authors:  Seyed Amin Izadi; Ali Mahloojifar; Babak Mohammadzadeh Asl
Journal:  J Med Ultrason (2001)       Date:  2015-07-28       Impact factor: 1.314

2.  Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2015-10-07       Impact factor: 1.314

3.  Adaptive windowing in contrast-enhanced intravascular ultrasound imaging.

Authors:  Brooks D Lindsey; K Heath Martin; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasonics       Date:  2016-04-27       Impact factor: 2.890

4.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

5.  Twofold minimum variance beamforming for enhanced ultrasound imaging.

Authors:  Sayed Mahmoud Sakhaei; Seyede Elham Shamsian
Journal:  J Med Ultrason (2001)       Date:  2017-04-21       Impact factor: 1.314

6.  Apodized adaptive beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2017-01-13       Impact factor: 1.314

7.  Improving Spatial Resolution Using Incoherent Subtraction of Receive Beams Having Different Apodizations.

Authors:  Anil Agarwal; Jonathan Reeg; Anthony S Podkowa; Michael L Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-16       Impact factor: 2.725

8.  Frequency-sum beamforming for passive cavitation imaging.

Authors:  Shima H Abadi; Kevin J Haworth; Karla P Mercado-Shekhar; David R Dowling
Journal:  J Acoust Soc Am       Date:  2018-07       Impact factor: 1.840

9.  Super-resolution image reconstruction using diffuse source models.

Authors:  Michael A Ellis; Francesco Viola; William F Walker
Journal:  Ultrasound Med Biol       Date:  2010-05-05       Impact factor: 2.998

10.  A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.

Authors:  Kazuyuki Dei; Brett Byram
Journal:  Ultrasonics       Date:  2018-04-25       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.