Literature DB >> 18986917

High frame-rate blood vector velocity imaging using plane waves: simulations and preliminary experiments.

Jesper Udesen1, Fredrik Gran, Kristoffer Lindskov Hansen, Jørgen Arendt Jensen, Carsten Thomsen, Michael Bachmann Nielsen.   

Abstract

Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow approximately followed the vessel wall, and that maximum velocity was approximately 1 m/s, which is a normal value for a healthy person. To further evaluate the method, the test person was scanned with magnetic resonance (MR) angiography. The volume flow derived from the MR scanning was compared with that from the ultrasound scanning. A deviation of 9% between the 2 volume flow estimates was found.

Entities:  

Mesh:

Year:  2008        PMID: 18986917     DOI: 10.1109/TUFFC.2008.858

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

1.  Accurate ultrasound imaging based on range point migration method for the depiction of fetal surface.

Authors:  Hirofumi Taki; Shinya Tanimura; Takuya Sakamoto; Tsuyoshi Shiina; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2014-09-13       Impact factor: 1.314

2.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

3.  Barker-coded excitation in ophthalmological ultrasound imaging.

Authors:  Sheng Zhou; Xiao-Chun Wang; Jun Yang; Jian-Jun Ji; Yan-Qun Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

4.  Comparison of virtual source synthetic aperture beamforming with an element-based model.

Authors:  Nick Bottenus
Journal:  J Acoust Soc Am       Date:  2018-05       Impact factor: 1.840

5.  Ultrasonic colour Doppler imaging.

Authors:  David H Evans; Jørgen Arendt Jensen; Michael Bachmann Nielsen
Journal:  Interface Focus       Date:  2011-05-06       Impact factor: 3.906

6.  Stolt's f-k migration for plane wave ultrasound imaging.

Authors:  Damien Garcia; Louis Le Tarnec; Stéphan Muth; Emmanuel Montagnon; Jonathan Porée; Guy Cloutier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

7.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

Review 8.  New developments in paediatric cardiac functional ultrasound imaging.

Authors:  Chris L de Korte; Maartje M Nillesen; Anne E C M Saris; Richard G P Lopata; Johan M Thijssen; Livia Kapusta
Journal:  J Med Ultrason (2001)       Date:  2013-12-20       Impact factor: 1.314

9.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

Review 10.  Vector velocity estimation of blood flow - A new application in medical ultrasound.

Authors:  Kristoffer Lindskov Hansen; Michael Bachmann Nielsen; Jørgen Arendt Jensen
Journal:  Ultrasound       Date:  2017-06-05
View more