Scheimpflug-based Optical Densitometry for Assessment of Corneal Opacity: An Objective Method to Monitor Interstitial Keratitis.

Alireza Peyman1,2, Mohsen Pourazizi1,2.   

Abstract

Entities:  

Year:  2018        PMID: 29719653      PMCID: PMC5905318          DOI: 10.4103/jovr.jovr_96_17

Source DB:  PubMed          Journal:  J Ophthalmic Vis Res        ISSN: 2008-322X


× No keyword cloud information.

PRESENTATION

Corneal optical clarity is essential for ocular function. Follow-up evaluation is required in patients with interstitial keratitis (IK) to ensure appropriate dosage of medications. A major concern in the evaluation of IK could be the inconsistency of non-objective methods for corneal haziness assessment. An objective method of haziness measurement would also be absolutely necessary in research projects, in particular, in a multicenter design to obviate variations and non-uniformity of records between observers. In this article, we discuss the objective measurement of corneal optical density in patients with IK using Scheimpflug-based corneal optical densitometry; this could be used in a clinical setting and is valuable for research projects. In our experiment, a 34 year-old male patient with herpetic IK [Figure 1] underwent Scheimpflug-based densitometry, while being treated with 1% prednisolone acetate eye drop (Precord®, Sina Darou, Tehran, Iran) in order to monitor the corneal stromal haze. After 1 month of treatment, along with clinical resolution [Figure 2], the optical corneal density decreased [Figures 3 and 4].
Figure 1

Nummular corneal stromal infiltrations before treatment.

Figure 2

Decreased stromal infiltrations after treatment.

Figure 3

Corneal densitometry display in the Pentacam before treatment.

Figure 4

Corneal densitometry display in the Pentacam after treatment.

Nummular corneal stromal infiltrations before treatment. Decreased stromal infiltrations after treatment. Corneal densitometry display in the Pentacam before treatment. Corneal densitometry display in the Pentacam after treatment.

DISCUSSION

Scheimpflug-based optical densitometry of the cornea, as a fairly new imaging method, is able to objectively measure corneal haziness in IK through a quantitative numerical assessment of the backscattered light. Cornea densito is provided as an add-on to the standard software of the Oculus Pentacam Scheimpflug device (Pentacam HR; Oculus GmbH, Wetzlar, Germany).[1] The Oculus Pentacam Cornea densito program automatically locates the corneal apex and analyzes an area of 12 mm in diameter around it using gray scale units to represent corneal haziness. These units range from 0 (no clouding) to 100 (totally opaque).[23] The first, central, zone covers the annulus over a 2-mm diameter zone, the second covers the 2–6-mm diameter zone, the third covers the 6–10-mm diameter zone, and the last covers the annulus over a 10–12-mm diameter zone.[2] The results of this analysis demonstrate the haziness score at three layers of depth: the anterior layer, comprising 120 μm of anterior cornea; the posterior layer, comprising 60 μm of the extreme posterior cornea; and the central layer, located between the anterior and posterior layers. A total densitometry score is also reported that represents the volume between the epithelium and endothelium.[2] Limited data and experience are available for corneal densitometry in clinical practice.[4] The improvement in optical density in concordance with reduction of inflammatory cells in the cornea could reflect the corneal response to treatment, which is useful in monitoring the treatment response. Objective quantification of corneal optical density with Cornea densito software permits direct comparison of different corneal optical densities[5] and provides a method to gauge the treatment response. Objective assessment of corneal haziness in IK has the potential to be a noninvasive, easy, rapid, and reliable tool for monitoring the patients. This objective evaluation is invaluable in research projects to eliminate inter-observer variations and for documentation of differences. Further studies and clinical evaluations are required to support our findings.

Financial Support and Sponsorship

Nil.

Conflicts of Interest

There are no conflicts of interest.
  5 in total

1.  Measuring corneal clouding in patients suffering from mucopolysaccharidosis with the Pentacam densitometry programme.

Authors:  H M Elflein; T Hofherr; F Berisha-Ramadani; V Weyer; C Lampe; M Beck; S Pitz
Journal:  Br J Ophthalmol       Date:  2013-05-17       Impact factor: 4.638

2.  Corneal densitometry in keratoconus.

Authors:  Bernardo Lopes; Isaac Ramos; Renato Ambrósio
Journal:  Cornea       Date:  2014-12       Impact factor: 2.651

3.  Corneal Densitometry for Quantification of Corneal Deposits in Monoclonal Gammopathies.

Authors:  Philip Enders; Udo Holtick; Friederike Schaub; Armin Tuchscherer; Manuel M Hermann; Christoph Scheid; Claus Cursiefen; Björn O Bachmann
Journal:  Cornea       Date:  2017-04       Impact factor: 2.651

4.  Corneal densitometry as an indicator of corneal health.

Authors:  Ahmad Muneer Otri; Usama Fares; Mouhamed A Al-Aqaba; Harminder S Dua
Journal:  Ophthalmology       Date:  2011-11-30       Impact factor: 12.079

5.  Anterior segment parameters using Pentacam and prediction of corneal endothelial cell loss after cataract surgery.

Authors:  Yang Kyeung Cho; Hwa Seok Chang; Tae Yoon La; Donghyun Ji; Hyunkyung Kim; Jin A Choi; Man Soo Kim
Journal:  Korean J Ophthalmol       Date:  2010-10-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.