Literature DB >> 23685998

Measuring corneal clouding in patients suffering from mucopolysaccharidosis with the Pentacam densitometry programme.

H M Elflein1, T Hofherr, F Berisha-Ramadani, V Weyer, C Lampe, M Beck, S Pitz.   

Abstract

AIM: To identify a means to objectively measure corneal clouding in patients with mucopolysaccharidosis in a prospective controlled clinical trial.
METHODS: Corneal haze was assessed by slit lamp examination and measured using the densitometry programme of the Pentacam, a rotating Scheimpflug camera in 33 mucopolysaccharidoses (MPS) patients and 32 controls.
RESULTS: Pentacam measurements were available in 31 right and 31 left eyes of 32 patients and in 32 left and right eyes of 32 subjects in the control group. Slit lamp findings correlated very well with corneal density measurements (Spearman correlation right eye (OD)/left eye (OS)=0.782/0.791). MPS patients had higher density units (median OD/OS=14.1/14.7) than control subjects (median OD/OS=6.7/6.9, p<0.001). In patients, the corneal centre density values (median OD/OS=13.8/14.0) did not differ from corneal periphery values (median OD/OS=14.3/14.7).
CONCLUSIONS: The densitometry programme of the Pentacam provides objective measurement of corneal haze in mucopolysaccharidosis patients.

Entities:  

Keywords:  Cornea; Diagnostic tests/Investigation

Mesh:

Year:  2013        PMID: 23685998     DOI: 10.1136/bjophthalmol-2012-302913

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  22 in total

Review 1.  Effect of corneal light scatter on vision: a review of the literature.

Authors:  Leopoldo Spadea; Giorgia Maraone; Francesca Verboschi; Enzo Maria Vingolo; Daniele Tognetto
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

2.  Assessment of corneal backward light scattering in the healthy cornea and factors affecting corneal transparency.

Authors:  Ali Bulent Cankaya; Kemal Tekin; Hasan Kiziltoprak; Sevilay Karahan; Pelin Yilmazbas
Journal:  Jpn J Ophthalmol       Date:  2018-03-16       Impact factor: 2.447

Review 3.  [Corneal densitometry : Value for keratoconus diagnostics].

Authors:  M Alnawaiseh; N Eter
Journal:  Ophthalmologe       Date:  2018-09       Impact factor: 1.059

Review 4.  Ocular manifestations and management recommendations of lysosomal storage disorders I: mucopolysaccharidoses.

Authors:  Carlton R Fenzl; Kyla Teramoto; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2015-09-07

5.  Clear-cornea cataract surgery: pupil size and shape changes, along with anterior chamber volume and depth changes. A Scheimpflug imaging study.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2014-10-24

6.  Corneal Backscatters as an Objective Index for Assessing Fuchs' Endothelial Corneal Dystrophy: A Pilot Study.

Authors:  Hsueh-Yen Chu; Ching-Hsi Hsiao; Phil Yeong-Fong Chen; David Hui-Kang Ma; Chee-Jen Chang; Hsin-Yuan Tan
Journal:  J Ophthalmol       Date:  2017-07-02       Impact factor: 1.909

7.  Pentacam corneal densitometry-guided treatment of adenoviral corneal subepithelial infiltrates: a comparative study between transepithelial phototherapeutic keratectomy and topical tacrolimus.

Authors:  Tarek Roshdy Elhamaky
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

8.  New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography.

Authors:  Xiao Yu Wang; Jorge Peraza-Nieves; Tian Qiao Zhang; Anil Rahul Rachwani; Irene Blanco-Domínguez; Carlos Rocha de Lossada; Afredo Manuel Adán-Civiera
Journal:  Eye (Lond)       Date:  2021-08-02       Impact factor: 4.456

9.  Measuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy.

Authors:  Jay W McLaren; Katrin Wacker; Katrina M Kane; Sanjay V Patel
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-01-01       Impact factor: 4.799

10.  One-Year Follow-Up of Changes in Corneal Densitometry After Accelerated (45 mW/cm2) Transepithelial Corneal Collagen Cross-Linking for Keratoconus: A Retrospective Study.

Authors:  Yang Shen; Weijun Jian; Ling Sun; Meng Li; Tian Han; Jooyeon Son; Xingtao Zhou
Journal:  Cornea       Date:  2016-11       Impact factor: 2.651

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.