Literature DB >> 27841786

Corneal Densitometry for Quantification of Corneal Deposits in Monoclonal Gammopathies.

Philip Enders1, Udo Holtick, Friederike Schaub, Armin Tuchscherer, Manuel M Hermann, Christoph Scheid, Claus Cursiefen, Björn O Bachmann.   

Abstract

PURPOSE: To assess the capability of Scheimpflug-based densitometry of the cornea to quantify light chain deposits in patients with active monoclonal gammopathies.
METHODS: This is a case-control study in which data from a leading tertiary university center in myeloma care were analyzed. Ten eyes of 5 patients with monoclonal gammopathy and 26 eyes of 13 healthy controls undergoing clinical evaluation and Scheimpflug-based measurements were included in the study. The main outcome measures were densitometry data of the 4 corneal layers-anterior layer (AL), central layer (CL), posterior layer, and total layer (TL)-in 4 different annuli (central annular zone 0-2 mm, intermediate annular zone 2-6 mm, peripheral annular zone 6-10 mm, and total annular zone 0-12 mm).
RESULTS: In 8 eyes of 4 patients with IgG-based gammopathy, corneal light backscatter was highest in the AL and decreased with increasing corneal depth. The peripheral annular zone showed a higher densitometry value compared with the corneal center. Compared with healthy controls, the AL (P < 0.001), the CL (P < 0.001), and the TL (P < 0.001) had significantly higher corneal light backscatter in patients with gammopathy in the total and the peripheral annular zones. In one patient with predominantly IgA-based disease, corneal light backscatter was not elevated.
CONCLUSIONS: Scheimpflug-based densitometry of the cornea is able to quantify opacification by immunoglobulin G light chain deposits in monoclonal gammopathies. This noninvasive technique can complement presently used in vivo confocal microscopy and corneal photography to objectivize corneal changes. Densitometry might allow monitoring of corneal immunoglobulin deposits in follow-up examinations.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27841786     DOI: 10.1097/ICO.0000000000001078

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Assessment of corneal topographic, tomographic, densitometric, and biomechanical properties of Fabry patients with ocular manifestations.

Authors:  Veysel Cankurtaran; Kemal Tekin; Ayse Idil Cakmak; Merve Inanc; Faruk Hilmi Turgut
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-08       Impact factor: 3.117

2.  The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry.

Authors:  Cagri Ilhan; Mehmet Ali Sekeroglu; Sibel Doguizi; Pelin Yilmazbas
Journal:  Beyoglu Eye J       Date:  2022-05-27

3.  Crystalline deposits in the cornea and various areas of the kidney as symptoms of an underlying monoclonal gammopathy: a case report.

Authors:  C Lindemann; P Enders; P T Brinkkoetter; L A Völker
Journal:  BMC Nephrol       Date:  2021-04-06       Impact factor: 2.388

4.  Corneal Densitometry and In Vivo Confocal Microscopy in Patients with Monoclonal Gammopathy-Analysis of 130 Eyes of 65 Subjects.

Authors:  Kitti Kormányos; Klaudia Kovács; Orsolya Németh; Gábor Tóth; Gábor László Sándor; Anita Csorba; Cecília Nóra Czakó; László Módis; Achim Langenbucher; Zoltán Zsolt Nagy; Gergely Varga; László Gopcsa; Gábor Mikala; Nóra Szentmáry
Journal:  J Clin Med       Date:  2022-03-26       Impact factor: 4.241

5.  Scheimpflug-based Optical Densitometry for Assessment of Corneal Opacity: An Objective Method to Monitor Interstitial Keratitis.

Authors:  Alireza Peyman; Mohsen Pourazizi
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun
  5 in total