Literature DB >> 29705684

What Factors Drive Taper Corrosion?

Robin Pourzal1, Hannah J Lundberg1, Deborah J Hall1, Joshua J Jacobs1.   

Abstract

Adverse local tissue reactions to corrosion products can lead to total hip arthroplasty failure. Although this problem has been well known for more than 25 years, it has seemingly increased in frequency over the recent years. The occurrence of corrosion is multifactorial-depending on implant, patient, and surgeon factors. As of now, there is no "one-size-fits-all" solution to prevent corrosion in total hip arthroplasty devices. Thus, it is imperative to fully understand the exact mechanisms of modular junction corrosion to prevent premature implant failure. This review highlights a few key concepts that need to be explored to minimize the impact of corrosion. The key concepts include (1) the prevention of micromotion, (2) the role of implant alloy metallurgy in the corrosion process, (3) the in vivo generation of a corrosive environment, and (4) potential unanticipated problems.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  adverse tissue reactions; corrosion; fretting; modular junction; taper; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29705684      PMCID: PMC6103829          DOI: 10.1016/j.arth.2018.03.055

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  30 in total

1.  In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion.

Authors:  Jeremy L Gilbert; Sachin Mali; Robert M Urban; Craig D Silverton; Joshua J Jacobs
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-11-24       Impact factor: 3.368

2.  In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements.

Authors:  Michel Nganbe; Usman Khan; Hakim Louati; Andrew Speirs; Paul E Beaulé
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-02-02       Impact factor: 3.368

3.  Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses.

Authors:  Annelie Rehmer; Nicholas E Bishop; Michael M Morlock
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-09-08       Impact factor: 2.063

4.  Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty.

Authors:  Sok Chuen Tan; Matthew G Teeter; Christopher Del Balso; James L Howard; Brent A Lanting
Journal:  J Arthroplasty       Date:  2015-02-28       Impact factor: 4.757

5.  Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces.

Authors:  Viswanathan Swaminathan; Jeremy L Gilbert
Journal:  J Biomed Mater Res A       Date:  2013-02-13       Impact factor: 4.396

6.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

7.  Erratum to: Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.

Authors:  Sevi B Kocagoz; Richard J Underwood; Daniel W MacDonald; Jeremy L Gilbert; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-05       Impact factor: 4.176

8.  Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements.

Authors:  Deborah J Hall; Robin Pourzal; Hannah J Lundberg; Mathew T Mathew; Joshua J Jacobs; Robert M Urban
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-08-26       Impact factor: 3.368

9.  New insights into hard phases of CoCrMo metal-on-metal hip replacements.

Authors:  Y Liao; R Pourzal; P Stemmer; M A Wimmer; J J Jacobs; A Fischer; L D Marks
Journal:  J Mech Behav Biomed Mater       Date:  2012-03-28

Review 10.  Trunnionosis in total hip arthroplasty: a review.

Authors:  Jaydev B Mistry; Morad Chughtai; Randa K Elmallah; Aloise Diedrich; Sidney Le; Melbin Thomas; Michael A Mont
Journal:  J Orthop Traumatol       Date:  2016-02-11
View more
  14 in total

1.  Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty.

Authors:  Jonathan A Gustafson; Robin Pourzal; Brett R Levine; Joshua J Jacobs; Hannah J Lundberg
Journal:  Bone Joint J       Date:  2020-07       Impact factor: 5.082

2.  Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers.

Authors:  Maren Bechstedt; Jonathan A Gustafson; Steven P Mell; Julian Gührs; Michael M Morlock; Brett R Levine; Hannah J Lundberg
Journal:  J Biomech       Date:  2020-02-25       Impact factor: 2.712

Review 3.  What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2020-01-15       Impact factor: 4.757

4.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

5.  Additively Manufactured Ti6Al4V-Si-Hydroxyapatite composites for articulating surfaces of load-bearing implants.

Authors:  Jose D Avila; Zumurda Alrawahi; Susmita Bose; Amit Bandyopadhyay
Journal:  Addit Manuf       Date:  2020-04-23

6.  In Vitro Evidence for Cell-Accelerated Corrosion Within Modular Junctions of Total Hip Replacements.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Dalton Morris; Abhijith Segu; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  J Orthop Res       Date:  2019-09-01       Impact factor: 3.494

Review 7.  Diagnosis and management of implant debris-associated inflammation.

Authors:  Stuart B Goodman; Jiri Gallo; Emmanuel Gibon; Michiaki Takagi
Journal:  Expert Rev Med Devices       Date:  2019-12-17       Impact factor: 3.166

8.  Hydroxyapatite reinforced Ti6Al4V composites for load-bearing implants.

Authors:  Jose D Avila; Kevin Stenberg; Susmita Bose; Amit Bandyopadhyay
Journal:  Acta Biomater       Date:  2021-01-12       Impact factor: 8.947

9.  Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.

Authors:  Dmitry Royhman; Robin Pourzal; Deborah Hall; Hannah J Lundberg; Markus A Wimmer; Joshua Jacobs; Nadim J Hallab; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-12

Review 10.  What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature.

Authors:  Claude B Rieker; Peter Wahl
Journal:  Materials (Basel)       Date:  2020-04-21       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.