Literature DB >> 22113876

In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion.

Jeremy L Gilbert1, Sachin Mali, Robert M Urban, Craig D Silverton, Joshua J Jacobs.   

Abstract

In vivo modular taper corrosion in orthopedic total joint replacements has been documented to occur for head-neck tapers, modular-body tapers, and neck-stem tapers. While the fretting corrosion mechanism by which this corrosion occurs has been described in the literature, this report shows new and as yet unreported mechanisms at play. A retrieved Ti-6Al-4V/Ti-6Al-4V neck-stem taper interface, implanted for 6 years is subjected to failure analysis to document taper corrosion processes that lead to oxide driven crack formation on the medial side of the taper. Metallurgical sectioning techniques and scanning electron microscopy analysis are used to document the taper corrosion processes. The results show large penetrating pitting attack of both sides of the taper interface where corrosion selectively attacks the beta phase of the microstructure and eventually consumes the alpha phase. The pitting attack evolves into plunging pits that ultimately develop into cracks where the crack propagation process is one of corrosion resulting in oxide formation and subsequent reorganization. This process drives open the crack and advances the front by a combination of oxide-driven crack opening stresses and corrosion attack at the tip. The oxide that forms has a complex evolving structure including a network of transport channels that provide access of fluid to the crack tip. This emergent behavior does not appear to require continued fretting corrosion to propagate the pitting and cracking. This new mechanism is similar to stress corrosion cracking where the crack tip stresses arise from the oxide formation in the crack and not externally applied tensile stresses.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Keywords:  corrosion; failure analysis; hip prosthesis; modular; titanium (alloys)

Mesh:

Substances:

Year:  2011        PMID: 22113876     DOI: 10.1002/jbm.b.31943

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  12 in total

Review 1.  What Factors Drive Taper Corrosion?

Authors:  Robin Pourzal; Hannah J Lundberg; Deborah J Hall; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2018-03-30       Impact factor: 4.757

2.  Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements.

Authors:  Deborah J Hall; Robin Pourzal; Hannah J Lundberg; Mathew T Mathew; Joshua J Jacobs; Robert M Urban
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-08-26       Impact factor: 3.368

3.  In Vitro Evidence for Cell-Accelerated Corrosion Within Modular Junctions of Total Hip Replacements.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Dalton Morris; Abhijith Segu; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  J Orthop Res       Date:  2019-09-01       Impact factor: 3.494

4.  Microstructure and electrochemical behavior of contemporary Ti6Al4V implant alloys.

Authors:  Mozart Queiroz Neto; Simona Radice; Deborah J Hall; Nicholas B Frisch; Mathew T Mathew; Alfons Fischer; Joshua J Jacobs; Robin Pourzal
Journal:  J Bio Tribocorros       Date:  2021-12-24

5.  Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket.

Authors:  Eric S Ouellette; Jeremy L Gilbert
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

6.  Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Guoxing Zheng; Mark Barba; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  Acta Biomater       Date:  2019-10-31       Impact factor: 8.947

7.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

8.  Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.

Authors:  Dmitry Royhman; Robin Pourzal; Deborah Hall; Hannah J Lundberg; Markus A Wimmer; Joshua Jacobs; Nadim J Hallab; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-12

9.  Primary hip replacement stem taper fracture due to corrosion in 3 patients.

Authors:  Michael M Morlock; Dennis Bünte; Harmen Ettema; Cees C Verheyen; Åke Hamberg; Jeremy Gilbert
Journal:  Acta Orthop       Date:  2016-01-11       Impact factor: 3.717

10.  Dual-taper modular hip implant: Investigation of 3-dimensional surface scans for component contact, shape, and fit.

Authors:  Nicholas B Frisch; Jonathan R Lynch; Robin Pourzal; Richard F Banglmaier; Craig D Silverton
Journal:  Arthroplast Today       Date:  2018-07-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.