Literature DB >> 29662920

Assessing CT acquisition parameters with visual-search model observers.

Zohreh Karbaschi1, Howard C Gifford1.   

Abstract

A principal difference between the channelized Hotelling (CH) and visual-search (VS) model observers is how they respond to noise texture in images. We compared the two observers in lesion-detection studies to evaluate linear and angular sampling parameters for CT. Simulated lung images were generated from a single two-dimensional mathematical torso phantom containing circular lesions of fixed radius and relative contrast. Projection datasets were produced for two detector pixel sizes and from 15 to 128 projections at 15 and 65 M counts per set. Filtered backprojection reconstructions were obtained with dimensions of [Formula: see text] and [Formula: see text]. A localization receiver operating characteristic study was conducted with two human observers, three single-feature VS observers, and a feature-adaptive VS observer. The effects of the sampling parameters on performance were similar for all of these observers. The CH observer, applied in location-known studies with and without background variability, was not affected by the variations in angular sampling. The two-stage VS framework was an effective modification of the CH observer for assessing the effects of noise texture on human-observer performance in this study.

Entities:  

Keywords:  computed tomography; data sampling; image quality; lesion detection; model observer; task-based assessment; tomographic imaging; visual search

Year:  2018        PMID: 29662920      PMCID: PMC5886130          DOI: 10.1117/1.JMI.5.2.025501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  15 in total

1.  Effect of filtering on the detection and localization of small Ga-67 lesions in thoracic single photon emission computed tomography images.

Authors:  R G Wells; P H Simkin; P F Judy; M A King; H Pretorius; H C Gifford
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

2.  Determination of the presampled MTF in computed tomography.

Authors:  J M Boone
Journal:  Med Phys       Date:  2001-03       Impact factor: 4.071

3.  Optimized image acquisition for breast tomosynthesis in projection and reconstruction space.

Authors:  Amarpreet S Chawla; Joseph Y Lo; Jay A Baker; Ehsan Samei
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  A Case for Wide-Angle Breast Tomosynthesis.

Authors:  Ehsan Samei; John Thompson; Samuel Richard; James Bowsher
Journal:  Acad Radiol       Date:  2015-04-24       Impact factor: 3.173

5.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

6.  The line spread function and modulation transfer function of a computed tomographic scanner.

Authors:  P F Judy
Journal:  Med Phys       Date:  1976 Jul-Aug       Impact factor: 4.071

7.  Visual signal detection. II. Signal-location identification.

Authors:  A E Burgess; H Ghandeharian
Journal:  J Opt Soc Am A       Date:  1984-08       Impact factor: 2.129

8.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Accounting for anatomical noise in search-capable model observers for planar nuclear imaging.

Authors:  Anando Sen; Howard C Gifford
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-26

10.  Effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector CT: phantom study.

Authors:  Kun Tang; Ling Wang; Rui Li; Jie Lin; Xiangwu Zheng; Guoquan Cao
Journal:  J Biomed Biotechnol       Date:  2012-04-23
View more
  1 in total

1.  Model and human observer reproducibility for detection of microcalcification clusters in digital breast tomosynthesis images of three-dimensionally structured test object.

Authors:  Dimitar Petrov; Nicholas Marshall; Kenneth Young; Guozhi Zhang; Hilde Bosmans
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.