Restricted single isocenter for multiple targets dynamic conformal arc (RSIMT DCA) technique for brain stereotactic radiosurgery (SRS) planning.

Jenghwa Chang1,2, A Gabriella Wernicke3, Susan C Pannullo4,5.   

Abstract

PURPOSE/
OBJECTIVES: In stereotactic radiosurgery (SRS), the multiple isocenters for multiple targets dynamic conformal arc (MIMT DCA) technique is traditionally used to treat multiple brain metastases, with one isocenter for each target. The single isocenter for multiple targets (SIMT) technique has recently been adopted to reduce the treatment time at the cost of plan quality. The objective of this study was to develop a restricted single isocenter for multiple targets DCA (RSIMT DCA) technique that can significantly reduce the treatment time but still maintain similar plan quality as the MIMT DCA technique.
MATERIALS AND METHODS: Treating multiple brain metastases with a single isocenter poses a challenge to SRS planning using DCA beams that are intrinsically 3D and do not modulate the beam intensity to spare the normal tissue between targets. To address this obstacle, we have developed a RSIMT DCA technique and used it to treat SRS patients with multiple brain metastases since February 2015. This planning approach is similar to the SIMT technique except that the number of targets for each isocenter is restricted and the distance between the isocenter and target is limited. In this technique, the targets are first split into batches so that all targets in a batch are within a chosen distance (e.g., 7 cm) of each other. All targets in a batch are combined into one target and the geometric center of the combined target is the isocenter for the group of DCA beams associated with that batch. Each DCA group typically consists of 3-4 DCA beams to irradiate 1-3 targets. For each DCA beam, the collimator angle is adjusted to minimize the exposure of normal tissue between targets. The dose of each treatment group is normalized so that the maximal point dose to the combined target is 125% of the prescription dose, which is equivalent to normalize the prescription dose to 80% isodose line. If the maximal point dose of a target is <123%, an additional beam is used to boost the maximal point dose of that target to 125%. To evaluate the plan quality, we randomly selected 10 cases planned with the RSIMT DCA technique, and re-planned them using the MIMT DCA technique. There were in total 38 PTVs, and 22 isocenters were used to treat all of these targets. The prescription for each target was 20 Gy with a maximal point dose of 25 Gy. Plan quality indexes were calculated and compared. Paired sample t-test was performed to determine if the mean normalized difference, (RSIMT-MIMT)/MIMT of each plan index was statistically significantly (p-value < 5%) larger than 0.
RESULTS: Satisfactory PTV coverage (V20Gy>95% and V19Gy=100%) was achieved for all plans using either technique. Most PTVs have a maximal point dose between 24.9 and 25.1 Gy, with 2 PTVs between 24.5 and 24.9 Gy. Overall, the plan quality was slightly better for the MIMT DCA technique and the normalized difference was statistically significantly larger than 0 for all investigated dose quality indexes. The normalized difference of body mean dose and conformity index (CI) between the RSIMT and MIMT techniques was respectively 4.2% (p=0.002) and 9.4% (p=0.001), indicating similar plan quality globally and in the high dose area. The difference was more pronounced for the mid-to-low dose spillage with the ratios of V12Gy and V10Gy/VPTV being 13.9% (p=3.8×10-6) and 14.9% (p=1.3×10-5), respectively. The treatment time was reduced by 30%-50% with the RSIMT DCA technique.
CONCLUSION: The RSIMT DCA technique can produce satisfactory SRS plans for treating multiple targets and can significantly reduce the treatment time.

Entities:  

Keywords:  dynamic conformal arc; multiple isocenters for multiple targets; rotational error; single isocenter for multiple targets

Year:  2018        PMID: 29657895      PMCID: PMC5893455     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  16 in total

1.  Dynamic arc radiosurgery and radiotherapy: commissioning and verification of dose distributions.

Authors:  G Grebe; M Pfaender; M Roll; L Luedemann; R E Wurm
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-04-01       Impact factor: 7.038

2.  Dynamic arc radiosurgery field shaping: a comparison with static field conformal and noncoplanar circular arcs.

Authors:  T D Solberg; K L Boedeker; R Fogg; M T Selch; A A DeSalles
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-04-01       Impact factor: 7.038

3.  Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets.

Authors:  Carl Stanhope; Zheng Chang; Zhiheng Wang; Fang-Fang Yin; Grace Kim; Joseph K Salama; John Kirkpatrick; Justus Adamson
Journal:  Pract Radiat Oncol       Date:  2015-10-23

4.  Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple itracranial metastases are spatially dispersed?

Authors:  Jay Morrison; Rodney Hood; Fang-Fang Yin; Joseph K Salama; John Kirkpatrick; Justus Adamson
Journal:  Med Dosim       Date:  2016-09-07       Impact factor: 1.482

5.  Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA).

Authors:  Yimei Huang; Karen Chin; Jared R Robbins; Jinkoo Kim; Haisen Li; Hanan Amro; Indrin J Chetty; James Gordon; Samuel Ryu
Journal:  Radiother Oncol       Date:  2014-07-02       Impact factor: 6.280

6.  Effect of Radiosurgery Alone vs Radiosurgery With Whole Brain Radiation Therapy on Cognitive Function in Patients With 1 to 3 Brain Metastases: A Randomized Clinical Trial.

Authors:  Paul D Brown; Kurt Jaeckle; Karla V Ballman; Elana Farace; Jane H Cerhan; S Keith Anderson; Xiomara W Carrero; Fred G Barker; Richard Deming; Stuart H Burri; Cynthia Ménard; Caroline Chung; Volker W Stieber; Bruce E Pollock; Evanthia Galanis; Jan C Buckner; Anthony L Asher
Journal:  JAMA       Date:  2016-07-26       Impact factor: 56.272

7.  Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial.

Authors:  David W Andrews; Charles B Scott; Paul W Sperduto; Adam E Flanders; Laurie E Gaspar; Michael C Schell; Maria Werner-Wasik; William Demas; Janice Ryu; Jean-Paul Bahary; Luis Souhami; Marvin Rotman; Minesh P Mehta; Walter J Curran
Journal:  Lancet       Date:  2004-05-22       Impact factor: 79.321

8.  Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial.

Authors:  Eric L Chang; Jeffrey S Wefel; Kenneth R Hess; Pamela K Allen; Frederick F Lang; David G Kornguth; Rebecca B Arbuckle; J Michael Swint; Almon S Shiu; Moshe H Maor; Christina A Meyers
Journal:  Lancet Oncol       Date:  2009-10-02       Impact factor: 41.316

9.  Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT).

Authors:  Jenghwa Chang; Kamil M Yenice; Kailiu Jiang; Margie Hunt; Ashwatha Narayana
Journal:  Med Dosim       Date:  2008-07-01       Impact factor: 1.482

10.  The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery.

Authors:  Gary A Ezzell
Journal:  J Appl Clin Med Phys       Date:  2017-02-02       Impact factor: 2.102

View more
  6 in total

1.  Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems.

Authors:  Giorgio Hamid Raza; Luca Capone; Paolo Tini; Martina Giraffa; Piercarlo Gentile; Giuseppe Minniti
Journal:  Radiat Oncol       Date:  2022-07-01       Impact factor: 4.309

2.  Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy.

Authors:  Naoki Hayashi; Shun Kurata; Yasunori Saito; Shuta Ogawa; Keisuke Yasui
Journal:  Radiol Phys Technol       Date:  2022-10-19

3.  Initial Experience With Single-Isocenter Radiosurgery to Target Multiple Brain Metastases Using an Automated Treatment Planning Software: Clinical Outcomes and Optimal Target Volume Margins Strategy.

Authors:  Giuseppe Minniti; Luca Capone; Filippo Alongi; Vanessa Figlia; Barbara Nardiello; Randa El Gawhary; Claudia Scaringi; Federico Bianciardi; Barbara Tolu; Piercarlo Gentile; Sergio Paolini
Journal:  Adv Radiat Oncol       Date:  2020-07-14

4.  Single isocenter stereotactic radiosurgery for patients with multiple brain metastases: dosimetric comparison of VMAT and a dedicated DCAT planning tool.

Authors:  Jan Hofmaier; Raphael Bodensohn; Sylvia Garny; Indrawati Hadi; Daniel F Fleischmann; Michael Eder; Yavuz Dinc; Michael Reiner; Stefanie Corradini; Katia Parodi; Claus Belka; Maximilian Niyazi
Journal:  Radiat Oncol       Date:  2019-06-11       Impact factor: 3.481

Review 5.  Single isocenter stereotactic irradiation for multiple brain metastases: current situation and prospects.

Authors:  Megumi Uto; Daichi Torizuka; Takashi Mizowaki
Journal:  Jpn J Radiol       Date:  2022-09-03       Impact factor: 2.701

6.  Dosimetric effect of rotational setup errors in stereotactic radiosurgery with HyperArc for single and multiple brain metastases.

Authors:  Tomohiro Sagawa; Shingo Ohira; Yoshihiro Ueda; Yuichi Akino; Hirokazu Mizuno; Masao Matsumoto; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2019-09-11       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.