Literature DB >> 19410139

Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT).

Jenghwa Chang1, Kamil M Yenice, Kailiu Jiang, Margie Hunt, Ashwatha Narayana.   

Abstract

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices--D(mean) (mean dose), conformity index (CI), V(70) (volume receiving >or= 70% of the prescription dose), and V(50) (volume receiving >or= 50% of the prescription dose)--were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D(95), V(95), D(max), D(min), and D(mean) of the PTV. The irradiated volume was approximately 23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by approximately 6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V(70), V(50), and D(mean) were reduced more effectively by a decrease in MLC width, while D(mean) of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

Entities:  

Mesh:

Year:  2008        PMID: 19410139     DOI: 10.1016/j.meddos.2008.06.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  8 in total

1.  Dosimetric comparison of 2.5 mm vs. 3.0 mm leaf width micro-multileaf collimator-based treatment systems for intracranial stereotactic radiosurgery using dynamic conformal arcs: implications for treatment planning.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Hidekazu Tanaka; Hiroaki Hoshi
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

2.  Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

Authors:  J A Tanyi; C M Kato; Y Chen; Z Chen; M Fuss
Journal:  Br J Radiol       Date:  2010-10-05       Impact factor: 3.039

3.  Dosimetric quantification of dose fall-off in liver SBRT planning using dual photon energy IMRT.

Authors:  J Henry; C Moreno; R L Crownover; D Baacke; N Papanikolaou; A N Gutierrez
Journal:  J Radiosurg SBRT       Date:  2016

4.  Restricted single isocenter for multiple targets dynamic conformal arc (RSIMT DCA) technique for brain stereotactic radiosurgery (SRS) planning.

Authors:  Jenghwa Chang; A Gabriella Wernicke; Susan C Pannullo
Journal:  J Radiosurg SBRT       Date:  2018

5.  Radiosurgery for mesial temporal lobe epilepsy following ROSE trial guidelines - A planning comparison between Gamma Knife, Eclipse, and Brainlab.

Authors:  Ganesh Narayanasamy; Steven Morrill; David Cousins; Joshua Liu; Garron Deshazer; Wesley Garner; Edvaldo Galhardo; Demitre Serletis; Jose Penagaricano
Journal:  J Appl Clin Med Phys       Date:  2019-09-18       Impact factor: 2.102

6.  Optimization of Minimum Segment Width Parameter in the Intensity-Modulated Radiotherapy Plan for Esophageal Cancer.

Authors:  Jun Hong; Ji-Hua Han; Hong-Lei Luo; Ya-Qi Song
Journal:  Int J Gen Med       Date:  2021-12-16

7.  Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach.

Authors:  Ghulam Murtaza; Muhammad Shamshad; Munir Ahmed; Shahid Mehmood; Ehsan Ullah Khan
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22

8.  Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites.

Authors:  Jinghao Duan; Xiangjuan Meng; Tonghai Liu; Yong Yin
Journal:  Radiat Oncol       Date:  2016-06-17       Impact factor: 3.481

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.