| Literature DB >> 29631386 |
Young Dae Cho1, Sung-Eun Kim2, Jeong Wook Lim3, Hyuk Jai Choi4, Yong Jun Cho4, Jin Pyeong Jeon4,5.
Abstract
OBJECTIVE: To compare peri-operative any symptomatic stroke after carotid angioplasty and stenting (CAS), based on the application or absence of a cerebral protection device.Entities:
Keywords: Carotid artery stenosis; Meta-analysis; Stents
Year: 2018 PMID: 29631386 PMCID: PMC6046577 DOI: 10.3340/jkns.2017.0202.001
Source DB: PubMed Journal: J Korean Neurosurg Soc ISSN: 1225-8245
Fig. 1.Flow diagram for identification of relevant studies.
Clinical data of the studies included in this meta-analysis
| No | Study or subgroup (years) | Study design/multicenter | Procedures | Events | Procedures | Events | NOS | Protection device | Stent |
|---|---|---|---|---|---|---|---|---|---|
| Protection | Stroke | Unprotection | Stroke | score | |||||
| 1 | Theron et al. (1996) [ | PC/yes | 93 | 2 | 123 | 3 | 6 | Occlusive latex balloon | Strecker |
| 2 | Parodi et al. (2000) [ | PCS/no | 25 | 0 | 21 | 1 | 6 | Angioguard | Wall stent |
| 3 | Al-Mubarak et al. (2001) [ | PC/no | 37 | 1 | 39 | 1 | 7 | Distal-balloon protection | Wall stent |
| 4 | Castriota et al. (2002) [ | PC/no | 150 | 1 | 125 | 3 | 7 | Angioguard/GuardWire occlusion | Multiple |
| TRAP vascular filtration/EPI filter wire | |||||||||
| Neuroshield/Parodi anti-embolism | |||||||||
| Medicorp occlusive balloon | |||||||||
| 5 | Pucillo et al. (2003) [ | PCS/yes | 22 | 1 | 55 | 2 | 7 | Distal balloon | — |
| Distal filter protection | |||||||||
| 6 | Dabrowski et al. (2003) [ | PCS/no | 20 | 1 | 55 | 3 | 6 | PercuSurge | Multiple |
| Angioguard | |||||||||
| 7 | Cohen et al. (2003) [ | RCS/yes | 108 | 3 | 179 | 9 | 6 | Balloon protection systems | |
| PercuSurge/GuideWire | |||||||||
| Filterwire EXTM | |||||||||
| 8 | Zahn et al. (2004) [ | PC/yes | 668 | 12 | 815 | 32 | 7 | Filter system/distal occlusion | — |
| 9 | Theiss et al. (2004) [ | PC/yes | 1609 | 25 | 923 | 19 | 7 | Distal/proximal balloon occlusion | Multiple |
| Filter based system | |||||||||
| 10 | Kihara et al. (2004) [ | RCS/yes | 36 | 0 | 43 | 1 | 6 | Angioguard/EPI filer | — |
| 11 | Gauvrit et al. (2004) [ | PCS/no | 7 | 0 | 15 | 1 | 7 | Filter type/Balloon type | Wall stent |
| 12 | Vos et al. (2005) [ | PC/no | 151 | 7 | 358 | 12 | 7 | Filterwire EX/Filterwire EZ | Multiple |
| Angioguard/Angioguard XP | |||||||||
| RX/Accunet/TRAP/Spiderwire | |||||||||
| Emboshield/Neuroshield | |||||||||
| 13 | Cosottini et al. (2005) [ | PC/no | 30 | 0 | 22 | 1 | 7 | Filterwire EZ | Carotid wall stent precise RX |
| 14 | Boltuch et al. (2005) [ | PC/no | 180 | 2 | 471 | 18 | 7 | Filterwire/Accunet/Mo.Ma device | Carotid wall stent Acculink |
| Spider/Interceptor | |||||||||
| 15 | Kastrup et al. (2006) [ | PCS/yes | 139 | 5 | 67 | 5 | 7 | Neuroshield/Angioguard | — |
| Emboshield/Filerwire | |||||||||
| 16 | Henry et al. (2006) [ | PC/no | 630 | 3 | 187 | 5 | 7 | Occlusion balloon/PercuSurge | Multiple |
| Theron's technique/Filter type/PI | |||||||||
| Angioguard/Emboshield/Accunet | |||||||||
| Fibernet/Arteria | |||||||||
| 17 | Halabi et al. (2006) [ | PCS/no | 49 | 0 | 67 | 3 | 7 | Angioguard/EPI filter wire EX | Multiple |
| Spider/Medtronic AVE carotid filter system | |||||||||
| 18 | Gupta et al. (2006) [ | RCS/no | 6 | 0 | 43 | 2 | 6 | — | Wall stent |
| 19 | Barbato et al. (2008) [ | RCT/no | 18 | 2 | 18 | 2 | - | RX Accunet | RX Acculink |
| 20 | Macdonald et al. (2010) [ | RCT/no | 15 | 1 | 15 | 1 | - | Emboshield | Carotid wall stent |
| 21 | Tallarita et al. (2011) [ | PC/no | 252 | 2 | 105 | 2 | 7 | Distal balloon occlusion | — |
| Distal filter type | |||||||||
| 22 | Wu et al. (2011) [ | RCS/no | 44 | 3 | 35 | 1 | 7 | Filterwire | Carotid eallstent Zilver |
| 23 | Kimiagar et al. (2012) [ | RCS/no | 60 | 1 | 56 | 6 | 7 | Angioguard RX | Smart stent/sinus-carotid-conicall RX |
| 24 | Giri et al. (2014) [ | PC/yes | 11883 | 244 | 364 | 6 | 7 | Distal balloon occlusion/distal filter type | — |
| 25 | Hung et al. (2016) [ | RCS/no | 208 | 10 | 29 | 3 | 7 | Filter wire/PercuSurge/NeuroShield/Emboshield | Self-expanding |
NOS : Newcastle-Ottawa scale, PC : prospective cohort, PCS : prospective case series, RCS : retrospective case series, RCT : randomized controlled trial
Fig. 2.A : Perioperative stroke events between protected and unprotected carotid angioplasty and stenting. B : Funnel plots for publication bias in perioperative stroke in all studies. CI : confidence interval.
Fig. 3.A : Perioperative stroke between protected and unprotected carotid angioplasty and stenting in patients with symptomatic carotid stenosis. B : Funnel plots for publication bias in perioperative stroke in patients with symptomatic carotid stenosis. CI : confidence interval.