Literature DB >> 22092586

Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

Alexandra Behneke1, Matthias Burwinkel, Nikolaus Behneke.   

Abstract

OBJECTIVES: The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients.
MATERIALS AND METHODS: In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer accuracy: (i) type of arch (maxilla/mandible), (ii) kind of template (single-tooth gap/interrupted dental arch/shortened dental arch/reduced residual dentition), (iii) surgical technique (flapless/open flap), (iv) number of sleeve-guided site preparation steps (fully guided placement/freehand placement/freehand final drilling). The data were analyzed using analysis of variance and the Bonferroni test.
RESULTS: The transfer accuracy of shoulder level, apex level, and angulation was similar for maxilla and mandible as well as for flapless and open flap approach. The differences were small in magnitude and reached no or only a borderline statistical significance. At implant sites in the reduced residual dentition group, the discrepancies were more pronounced than in the single-tooth gap group, whereas no significant differences could be determined between free ending templates in the shortened dental arch and bilateral anchored templates in the interrupted dental arch. Implant placement through the guide allowed a more accurate implementation of the virtual plan to the surgical site than freehand insertion or freehand final drilling.
CONCLUSION: CBCT-derived laboratory-based surgical templates enabled an implant placement in the cancellous maxilla as well as flapless procedures without compromising the transfer accuracy. The number and distribution of the remaining teeth as well as the number of sleeve-guided implant site preparation steps influenced the extent of deviation that can be achieved in partial edentulism.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092586     DOI: 10.1111/j.1600-0501.2011.02337.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  24 in total

1.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

Review 2.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

3.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

Review 4.  3D imaging, 3D printing and 3D virtual planning in endodontics.

Authors:  Pratik Shah; B S Chong
Journal:  Clin Oral Investig       Date:  2018-01-12       Impact factor: 3.573

5.  Accuracy of computer-assisted implant placement with insertion templates.

Authors:  Eleni Naziri; Alexander Schramm; Frank Wilde
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-05-13

6.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

7.  Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study.

Authors:  Sigmar Schnutenhaus; Marie Wagner; Cornelia Edelmann; Ralph G Luthardt; Heike Rudolph
Journal:  Dent J (Basel)       Date:  2021-05-10

8.  Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides.

Authors:  Tabea Flügge; Wiebe Derksen; Jobine Te Poel; Bassam Hassan; Katja Nelson; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2016-07-20       Impact factor: 5.977

Review 9.  A review of virtual planning software for guided implant surgery - data import and visualization, drill guide design and manufacturing.

Authors:  Florian Kernen; Jaap Kramer; Laura Wanner; Daniel Wismeijer; Katja Nelson; Tabea Flügge
Journal:  BMC Oral Health       Date:  2020-09-10       Impact factor: 2.757

10.  Accuracy of computer-guided implantation in the placement of one-piece ceramic dental implants in the anterior region: A prospective clinical study.

Authors:  Nopparat Suksod; Chatchai Kunavisarut; Jira Kitisubkanchana
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.