Literature DB >> 20545538

Accuracy evaluation of computed tomography-derived stereolithographic surgical guides in zygomatic implant placement in human cadavers.

Bruno R Chrcanovic1, Davidson R Oliveira, Antônio L Custódio.   

Abstract

Presurgical planning is essential to achieve esthetic and functional implants. For implant planning and placement, the association of computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques furnishes some advantages regarding tridimensional determination of the patient's anatomy and fabrication of both anatomic models and surgical guides. The goal of this clinical study was to determine the angular deviations between planned and placed zygomatic implants using stereolithographic surgical guides in human cadavers. A total of 16 zygomatic implants were placed, 4 in each cadaver, with the use of stereolithographic (SLA) surgical guides generated by computed tomography (CT). A new CT scan was made after implant insertion. The angle between the long axis of the planned and actual implants was calculated. The mean angular deviation of the long axis between the planned and placed implants was 8.06 ± 6.40 (mean ± SD) for the anterior-posterior view, and 11.20 ± 9.75 (mean ± SD) for the caudal-cranial view. Use of the zygomatic implant, in the context of this protocol, should probably be reevaluated because some large deviations were noted. An implant insertion guiding system is needed because this last step is carried out manually. It is recommended that the sinus slot technique should be used together with the CT-based drilling guide to enhance final results. Further research to enhance the precision of zygomatic implant placement should be undertaken.

Entities:  

Mesh:

Year:  2010        PMID: 20545538     DOI: 10.1563/AAID-JOI-D-09-00074

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  10 in total

Review 1.  Zygomatic implants: a critical review of the surgical techniques.

Authors:  Bruno Ramos Chrcanovic; Alexsander Ribeiro Pedrosa; Antônio Luís Neto Custódio
Journal:  Oral Maxillofac Surg       Date:  2012-01-25

Review 2.  Survival and complications of zygomatic implants: a systematic review.

Authors:  Bruno Ramos Chrcanovic; Mauro Henrique Nogueira Guimarães Abreu
Journal:  Oral Maxillofac Surg       Date:  2012-05-06

Review 3.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

4.  Positioning accuracy assessment of minimally invasive percutaneous injection techniques for the treatment of temporomandibular disorders.

Authors:  Antônio Luís Neto Custódio; Andrew Cameron; Mahmoud Bakr; Chris Little; Bruno Ramos Chrcanovic; Peter Reher
Journal:  Dentomaxillofac Radiol       Date:  2020-07-24       Impact factor: 2.419

5.  Flapless versus conventional flapped dental implant surgery: a meta-analysis.

Authors:  Bruno Ramos Chrcanovic; Tomas Albrektsson; Ann Wennerberg
Journal:  PLoS One       Date:  2014-06-20       Impact factor: 3.240

6.  Dynamic Navigation for Zygomatic Implants: A Case Report about a Protocol with Intraoral Anchored Reference Tool and an Up-To-Date Review of the Available Protocols.

Authors:  Gerardo Pellegrino; Giuseppe Lizio; Francesco Basile; Luigi Vito Stefanelli; Claudio Marchetti; Pietro Felice
Journal:  Methods Protoc       Date:  2020-11-05

7.  Accuracy of a Computer-Aided Dynamic Navigation System in the Placement of Zygomatic Dental Implants: An In Vitro Study.

Authors:  Juan Ramón González Rueda; Irene García Ávila; Víctor Manuel de Paz Hermoso; Elena Riad Deglow; Álvaro Zubizarreta-Macho; Jesús Pato Mourelo; Javier Montero Martín; Sofía Hernández Montero
Journal:  J Clin Med       Date:  2022-03-05       Impact factor: 4.241

8.  A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy.

Authors:  Francesco Grecchi; Luigi V Stefanelli; Fabrizio Grivetto; Emma Grecchi; Rami Siev; Ziv Mazor; Massimo Del Fabbro; Nicola Pranno; Alessio Franchina; Vittorio Di Lucia; Francesca De Angelis; Funda Goker
Journal:  Int J Environ Res Public Health       Date:  2021-06-07       Impact factor: 3.390

9.  Accuracy of digital planning in zygomatic implants.

Authors:  B Xing Gao; O Iglesias-Velázquez; F G F Tresguerres; A Rodríguez González Cortes; I F Tresguerres; R Ortega Aranegui; R M López-Pintor; J López-Quiles; J Torres
Journal:  Int J Implant Dent       Date:  2021-07-22

10.  Reliability and accuracy of dynamic navigation for zygomatic implant placement.

Authors:  Yiqun Wu; Baoxin Tao; Kengliang Lan; Yihan Shen; Wei Huang; Feng Wang
Journal:  Clin Oral Implants Res       Date:  2022-02-15       Impact factor: 5.021

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.