OBJECTIVE: The aim of the present study is to evaluate the effect of electrode discrimination based on electrode to modiolus distance in different cochlear implant models, using image information to estimate the outcomes after an implantation on electrode discrimination
METHODS: A descriptive prospective randomized study performed during 16 months. A psychoacoustic platform was used to evaluate patients' electrode discrimination capabilities of patients. For the acquisition of the images, a cone beam computed tomography was used to assess postcochlear implantation of electrodes' position. We considered two other new measurements: the intracochlear position index, which indicates how far is the electrode from the modiolar wall, and the homogeneity factor (HF), which provides us with information about the distance between the electrodes and the modiolus
RESULTS: 21 postlingually deaf adults showing different CI models [CI522 (n = 7), CI512 (n = 7), and CI532 (n = 7)] that corresponded to the lateral and perimodiolar array electrodes. The average success rate of the CI522 group was 47%, of the CI512 group was 48%, and of the CI532 group was 77%. There is statistically significant difference between groups CI532-CI522 (p = 0.0033) and CI532-CI512 (p = 0.0027)
CONCLUSION: The Nucleus CI532 offers a better perimodiolar placement. HF and IPI measurements provide information about the electrodes location inside the cochlea, being related to electrode discrimination.

Entities:  

Keywords:  Cochlear implant; Electrode discrimination test; Intracochlear position index

Mesh:

Year:  2018        PMID: 29610960     DOI: 10.1007/s00405-018-4943-2

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  33 in total

1.  Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays.

Authors:  M Tykocinski; L T Cohen; B C Pyman; T Roland; C Treaba; J Palamara; M C Dahm; R K Shepherd; J Xu; R S Cowan; N L Cohen; G M Clark
Journal:  Am J Otol       Date:  2000-03

2.  Speech perception scores in cochlear implant recipients: An analysis of ceiling effects in the CUNY sentence test (Quiet) in post-lingually deafened cochlear implant recipients.

Authors:  Azadeh Ebrahimi-Madiseh; Robert H Eikelboom; Dona Mp Jayakody; Marcus D Atlas
Journal:  Cochlear Implants Int       Date:  2016-02-05

Review 3.  Cone-beam imaging: applications in ENT.

Authors:  C Hodez; C Griffaton-Taillandier; I Bensimon
Journal:  Eur Ann Otorhinolaryngol Head Neck Dis       Date:  2011-04-02       Impact factor: 2.080

4.  Stimulation parameters differ between current anti-modiolar and peri-modiolar electrode arrays implanted within the same child.

Authors:  M J Polonenko; S L Cushing; K A Gordon; B Allemang; S Jewell; B C Papsin
Journal:  J Laryngol Otol       Date:  2016-10-14       Impact factor: 1.469

5.  Deactivating Cochlear Implant Electrodes Based on Pitch Information for Users of the ACE Strategy.

Authors:  Deborah Vickers; Aneeka Degun; Angela Canas; Thomas Stainsby; Filiep Vanpoucke
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

6.  Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds.

Authors:  Lindsay DeVries; Rachel Scheperle; Julie Arenberg Bierer
Journal:  J Assoc Res Otolaryngol       Date:  2016-02-29

7.  Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation.

Authors:  R K Shepherd; S Hatsushika; G M Clark
Journal:  Hear Res       Date:  1993-03       Impact factor: 3.208

8.  Research plan for evaluating subjects presently fitted with implanted auditory prostheses.

Authors:  R C Bilger; F O Black; N T Hopkinson
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1977 May-Jun

9.  In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays.

Authors:  D R Ketten; M W Skinner; G Wang; M W Vannier; G A Gates; J G Neely
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1998-11

10.  In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.

Authors:  Margaret W Skinner; Timothy A Holden; Bruce R Whiting; Arne H Voie; Barry Brunsden; J Gail Neely; Eugene A Saxon; Timothy E Hullar; Charles C Finley
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  2007-04
View more
  3 in total

1.  Simpler and effective radiological evaluations for modiolar proximity of a slim modiolar cochlear implant electrode.

Authors:  Sang-Yeon Lee; Jin Hee Han; Marge Carandang; Yun Jung Bae; Byung Yoon Choi
Journal:  Sci Rep       Date:  2020-10-19       Impact factor: 4.379

2.  Assessing the Placement of the Cochlear Slim Perimodiolar Electrode Array by Trans Impedance Matrix Analysis: A Temporal Bone Study.

Authors:  Ángel Ramos de Miguel; Diego Riol Sancho; Juan Carlos Falcón-González; Joana Pavone; Leandro Rodríguez Herrera; Silvia Borkoski Barreiro; Nadia Falcón Benitez; Ángel Ramos Macias
Journal:  J Clin Med       Date:  2022-07-06       Impact factor: 4.964

3.  Outcomes for a clinically representative cohort of hearing-impaired adults using the Nucleus® CI532 cochlear implant.

Authors:  Matthias Hey; Nicole Neben; Timo Stöver; Uwe Baumann; Alexander Mewes; Tim Liebscher; Mark Schüssler; Antje Aschendorff; Thomas Wesarg; Andreas Büchner; Paula Greenham; Ulrich Hoppe
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-03-05       Impact factor: 2.503

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.