In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.

Margaret W Skinner1, Timothy A Holden, Bruce R Whiting, Arne H Voie, Barry Brunsden, J Gail Neely, Eugene A Saxon, Timothy E Hullar, Charles C Finley.   

Abstract

OBJECTIVES: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays.
METHODS: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0 degrees start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule.
RESULTS: The group mean array insertion depth was 477 degrees (range, 286 degrees to 655 degrees). The word scores were negatively correlated (r = -0.59; p = .028) with the number of electrodes in the scala vestibuli.
CONCLUSIONS: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.

Entities:  

Mesh:

Year:  2007        PMID: 17542465

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol Suppl        ISSN: 0096-8056


  93 in total

1.  Optimizing the perception of soft speech and speech in noise with the Advanced Bionics cochlear implant system.

Authors:  Laura K Holden; Ruth M Reeder; Jill B Firszt; Charles C Finley
Journal:  Int J Audiol       Date:  2011-01-28       Impact factor: 2.117

Review 2.  Probing the electrode-neuron interface with focused cochlear implant stimulation.

Authors:  Julie Arenberg Bierer
Journal:  Trends Amplif       Date:  2010-06

3.  Partial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus.

Authors:  Julie Arenberg Bierer; Steven M Bierer; John C Middlebrooks
Journal:  Hear Res       Date:  2010-08-18       Impact factor: 3.208

4.  Impact of the surgical experience on cochleostomy location: a comparative temporal bone study between endaural and posterior tympanotomy approaches for cochlear implantation.

Authors:  Clair Vandersteen; Thomas Demarcy; Coralie Roger; Eric Fontas; Charles Raffaelli; Nicholas Ayache; Hervé Delingette; Nicolas Guevara
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-10-16       Impact factor: 2.503

5.  Force Perception Thresholds in Cochlear Implantation Surgery.

Authors:  Louis B Kratchman; Daniel Schuster; Mary S Dietrich; Robert F Labadie
Journal:  Audiol Neurootol       Date:  2016-08-30       Impact factor: 1.854

6.  Minimum Reporting Standards for Adult Cochlear Implantation.

Authors:  Oliver F Adunka; Bruce J Gantz; Camille Dunn; Richard K Gurgel; Craig A Buchman
Journal:  Otolaryngol Head Neck Surg       Date:  2018-03-20       Impact factor: 3.497

7.  Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.

Authors:  Christopher K Giardina; Tatyana E Khan; Stephen H Pulver; Oliver F Adunka; Craig A Buchman; Kevin D Brown; Harold C Pillsbury; Douglas C Fitzpatrick
Journal:  Ear Hear       Date:  2018 Nov/Dec       Impact factor: 3.570

8.  Evaluation of Rigid Cochlear Models for Measuring Cochlear Implant Electrode Position.

Authors:  Ahmet Cakir; Robert F Labadie; M Geraldine Zuniga; Benoit M Dawant; Jack H Noble
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

9.  Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani.

Authors:  Laura K Holden; Jill B Firszt; Ruth M Reeder; Rosalie M Uchanski; Noël Y Dwyer; Timothy A Holden
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

10.  Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array.

Authors:  Maja Svrakic; J Thomas Roland; Sean O McMenomey; Mario A Svirsky
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.