| Literature DB >> 29607469 |
Michele Tepedino1, Valeria Paoloni2, Paola Cozza2, Claudio Chimenti3.
Abstract
BACKGROUND: Clear aligner treatment offers several advantages, but the available literature shows that some kind of tooth movements are unpredictable. In addition, the majority of the studies are focused on one clear aligner system, while different characteristics of various systems can provide different treatment outcomes. The aim of the present retrospective cohort study was to evaluate the predictability of Nuvola® aligner system in achieving torque movements of anterior teeth.Entities:
Keywords: Clear aligners; Orthodontic tooth movement; Torque
Mesh:
Year: 2018 PMID: 29607469 PMCID: PMC5879033 DOI: 10.1186/s40510-018-0207-3
Source DB: PubMed Journal: Prog Orthod ISSN: 1723-7785 Impact factor: 2.750
Demographic composition of the study sample
| Males ( | Females ( | Total ( | |
|---|---|---|---|
| Age (mean ± SD) | 30.7 ± 8.5 | 30.7 ± 10.8 | 30.7 ± 9.3 |
Age is expressed in years
Fig. 1Torque measurement using VAM software. Reference landmarks and points defining the labial FACC of the anterior teeth were localised on every digital model. a Occlusal view and b frontal view
Fig. 2Bland–Altman plot for repeated measurements of central incisors, confirming the absence of systematic errors
Fig. 3Bland–Altman plot for repeated measurements of lateral incisors, confirming the absence of systematic errors
Fig. 4Bland–Altman plot for repeated measurements of canines, confirming the absence of systematic errors
Descriptive statistics for torque measurements
| T0 | T1 | TS | |||
|---|---|---|---|---|---|
| Upper arch ( | Left side | Canine | 12.7 ± 5.7 | 11.4 ± 4.5 | 11.6 ± 4.9 |
| Lateral incisor | 10.7 ± 5.6 | 8.8 ± 4.9 | 9.4 ± 5.5 | ||
| Central incisor | 9.4 ± 5.4 | 7.7 ± 4.5 | 9.1 ± 5.8 | ||
| Right side | Canine | 12.0 ± 4.9 | 10.6 ± 5.2 | 9.9 ± 4.5 | |
| Lateral incisor | 9.3 ± 4.8 | 8.1 ± 4.4 | 8.5 ± 4.8 | ||
| Central incisor | 8.9 ± 5.7 | 7.7 ± 4.3 | 8.3 ± 5.5 | ||
| Lower arch ( | Left side | Canine | 14.3 ± 6.2 | 11.8 ± 4.9 | 11.6 ± 5.4 |
| Lateral incisor | 11.0 ± 4.8 | 8.6 ± 3.8 | 8.6 ± 4.3 | ||
| Central incisor | 11.0 ± 4.9 | 9.3 ± 5.1 | 9.9 ± 4.6 | ||
| Right side | Canine | 16.2 ± 6.1 | 14.3 ± 5.8 | 15.0 ± 5.7 | |
| Lateral incisor | 8.1 ± 4.7 | 7.8 ± 3.9 | 7.5 ± 3.7 | ||
| Central incisor | 9.8 ± 4.5 | 9.4 ± 4.8 | 9.1 ± 4.2 |
Torque is expressed in degrees (°)
Paired t test for the comparison of the predicted (TS) and achieved (T1) torque
| Mean difference | Standard error |
| 95% confidence interval | ||||
|---|---|---|---|---|---|---|---|
| Lower bound | Upper bound | ||||||
| Upper arch ( | Left side | Canine | 0.21* | 0.52 | 0.697 | − 1.26 | 0.85 |
| Lateral incisor | − 1.57† | – | 0.116 | – | – | ||
| Central incisor | − 1.86† | – | 0.063 | – | – | ||
| Right side | Canine | − 1.0† | – | 0.318 | – | – | |
| Lateral incisor | − 0.44* | 0.5 | 0.437 | − 1.59 | 0.70 | ||
| Central incisor | − 0.73† | – | 0.466 | – | – | ||
| Lower arch ( | Left side | Canine | 0.21* | 0.67 | 0.753 | − 1.16 | 1.59 |
| Lateral incisor | 0.03* | 0.72 | 0.965 | − 1.46 | 1.52 | ||
| Central incisor | − 0.71* | 0.66 | 0.289 | − 2.07 | 0.64 | ||
| Right side | Canine | − 0.67* | 0.91 | 0.472 | − 2.54 | 1.21 | |
| Lateral incisor | 0.38* | 0.91 | 0.683 | − 1.50 | 2.25 | ||
| Central incisor | 0.25* | 0.55 | 0.654 | − 0.89 | 1.39 | ||
Torque values are expressed as degrees (°)
*Paired sample t test
†Z statistics from Wilcoxon signed-rank test